48
WATER CONNECTIONS
Carefully comply with any national or regional
regulations in force.
Water
installation must have the following
characteristics:
Temperature
:
10÷12 °C
Dynamic Pressure :
2 ÷ 4 bar (200 ÷ 400 kPa).
If the dynamic pressure is lower than
specified on the data plate of the machine, it is
advisable to install a Pump for pressure
increase.
If the dynamic pressure is higher than 4 bar, it is
advisable to install a pressure reduction.
Hardness:
between
7,2 and 12,5 °French
.
If the hardness values are higher than
those mentioned above, it is advisable to install
a
water-softener.
WORK TEMPERATURES
Water temperature 55÷60 °C
Rinse temperature 80÷85 °C
DO NOT TAMPER WITH THE THERMOSTAT
CALIBRATION
WATER DRAIN
According to the dimensions of the drawing;
water drain and feeding pipe should have
the same
diameter of the water inlet of the machine.
It must be furnished with a siphon and have
a right slope.
The machine is provided with a flexible pipe
for the connection with the water-work.
See page 45 draw 3 for connections.
Make sure there are no throttlings along the
pipe.
Carefully comply with any national or
regional regulations in force.