SAFETY SYMBOL:

This symbol indicates dangerous voltages present within the power supply.  Isolation
transformers should be used between the AC mains and the power supply if work is to be
carried out with the safety covers removed.

GENERAL SAFETY INSTRUCTIONS

The UltraFlex power supply series is designed for use within other equipment or enclosures. 
Access is restricted to authorized personnel only. 

For safe installation and operation of this product, carefully follow the instructions below:

A.

Do not install, operate or test this product near water, and do not spill any liquid on it.

B.

Do not touch the product when the input supply is connected.

C.

Do not operate this product unless it is in a secure position.

D.

When cleaning the product, make sure the input supply is disconnected and use only a
damp cloth.

E.

Never push objects of any kind into the product through slots in its case, as this could
result in electric shock or a fire hazard.

F.

Slots in the product case are designed for ventilation and must not be obstructed when
the product is installed and/or operated.

G.

Make sure the unit is supplied only by a power source of the type indicated on its label.

H.

When securing the product, do not use screws that infringe the maximum penetration
depth specified on the mechanical drawing within this handbook.

I.

The unit covers are designed only to protect skilled personnel from hazards. They must
not be used as part of the external covers of any equipment where they may be
accessible to operators, since, under full load conditions, parts of the unit chassis may
reach temperatures in excess of those considered safe for operator access.

J.

All servicing, repair and testing of this product must be carried out by competent
personnel who are familiar with the hazards of AC/DC line operated equipment and with
the particular dangers associated with switched mode power supplies.

K.

AFTER DISCONNECTING THE AC SOURCE, ALLOW 5 MINUTES BEFORE
TOUCHING THE UNIT TO ALLOW CAPACITORS WITHIN THE UNIT TO
DISCHARGE.

L.

The low-voltage output from the power supply unit shall not be user-accessible as
defined in EN 60950.

Summary of Contents for UF1500 Series

Page 1: ...INSTALLATION MANUAL ULTRAFLEX POWER SUPPLY UF1500 Series 3055 Del Sol Blvd San Diego CA 92154 Phone 619 575 4400 Fax 619 429 1011 P N IMUE1500 Rev C DATE February 2002...

Page 2: ...NS 5 INPUT FUSE 6 RECEIPT AND UNPACKING 6 MOUNTING REQUIREMENTS AND COOLING 7 INPUT POWER CONNECTIONS 7 AC INPUT AND OUTPUT POWER RATINGS 7 EMI 8 INPUT TRANSIENT ESD PROTECTION 8 REMOTE SENSE 8 OUTPUT...

Page 3: ...TURE SHUTDOWN 10 OPERATING ENVIRONMENT 10 SIZE AND WEIGHT 10 COOLING 11 SHOCK VIBRATION 11 PACKAGE DROP 11 RELIABILITY PREDICTION 11 MATING SIGNAL CONTROL CONNECTOR INFORMATION 11 GLOBAL SIGNALS 11 OU...

Page 4: ...UF1500 Series power supply Manual part no IMUE1500 PART NUMBER CONFIGURATION U E Z 1 _ _ _ _ _ _ _ UltraFlex Case Code Global Signals Output Module Codes SEE PAGE 14 EN55022 Level B FCC20780 Class A...

Page 5: ...ts in the product case are designed for ventilation and must not be obstructed when the product is installed and or operated G Make sure the unit is supplied only by a power source of the type indicat...

Page 6: ...quirements this terminal must be marked with as defined in IEC417 No 5019a The customer should therefore affix an adhesive label which will pass the 15 second rub test IEC950 section 1 7 15 showing th...

Page 7: ...takes and exhaust slots must not be obstructed The intake air temperature should be limited to allow the unit to operate in accordance with the thermal derating envelope of the electrical specificatio...

Page 8: ...supply to the sense points To meet specifications and output voltage set point of the output modules the sense lines must be connected to the load or locally to the power supply output terminals The r...

Page 9: ...4 8V OVP activates the internal shutdown latch of the module until the AC input power is recycled OFF to ON to clear the latch and resume normal operation once the OVP problem has been corrected OUTPU...

Page 10: ...less than 02 per o C over the ambient temperature range of 0 50 o C After 30 minute warm up NO LOAD OPERATION Operation at no load will not cause damage to the UltraFlex supply however the output volt...

Page 11: ...J2 Dual Output Connector Kit 951492 TO ORDER CONNECTORS DIRECT FROM AMP Single Output Input Connector AMP P N 87977 3 holds 10 Pins Dual Output Connector AMP P N 87977 1 holds 6 Pins Pin For Above Co...

Page 12: ...dual output module Compensates for load cable drop from power supply to sense point 25V per terminal To meet regulation the remote sense must be connected to the load or locally to the power supply R...

Page 13: ...nal causes the current share node to disconnect Maximum ratings for the output transistor are 20V 4mA Current Monitor J1 pin 9 This is an analog signal proportional to the output current 0 2VDC 2VDC a...

Page 14: ...6W 2 P 24 V 21 6 26 4 8 5A 204W 1 Q 24 V 21 6 26 4 15A 396W 2 R 24 V 21 6 26 4 25A 600W 3 S 48 V 43 2 52 8 4A 211W 1 T 48 V 43 2 52 8 8A 384W 2 U 48 V 43 2 52 8 12 5 600W 3 V 12 5 V 10 8 13 2 4 5 6 0...

Page 15: ...to output voltage setting Therefore consideration should be given to electrical energy hazards from these outputs THERMAL DERATING GUIDELINE for UltraFlex UF1500 Power Supply Series Derating UF1500 Se...

Page 16: ...REV C Page 16 of 17 OUTLINE DRAWING...

Page 17: ...REV C Page 17 of 17 LABEL CONNECTION DIAGRAM...

Reviews: