background image

REV C

Page 3 of 17

TURN-OFF/TURN-ON

9

TURN ON TIME

9

NOISE AND RIPPLE

9

DYNAMIC LOAD TRANSIENT RESPONSE

10

DYNAMIC CROSS REGULATION

10

TEMPERATURE COEFFICIENT

10

NO LOAD OPERATION

10

OVER TEMPERATURE SHUTDOWN

10

OPERATING ENVIRONMENT

10

SIZE AND WEIGHT

10

COOLING

11

SHOCK & VIBRATION

11

PACKAGE DROP

11

RELIABILITY PREDICTION

11

MATING SIGNAL & CONTROL CONNECTOR INFORMATION

11

GLOBAL SIGNALS

11

OUTPUT MODULE SIGNALS & FEATURES

12

MODULE RATING WITH MODEL NUMBERS: UE Z 1 - X X X X X X

14

NOTE:  ENERGY HAZARDS

15

THERMAL DERATING GUIDELINE

15

MAXIMUM POWER VS. AC LINE

15

LABEL / CONNECTION DIAGRAM

17

Summary of Contents for UF1500 Series

Page 1: ...INSTALLATION MANUAL ULTRAFLEX POWER SUPPLY UF1500 Series 3055 Del Sol Blvd San Diego CA 92154 Phone 619 575 4400 Fax 619 429 1011 P N IMUE1500 Rev C DATE February 2002...

Page 2: ...NS 5 INPUT FUSE 6 RECEIPT AND UNPACKING 6 MOUNTING REQUIREMENTS AND COOLING 7 INPUT POWER CONNECTIONS 7 AC INPUT AND OUTPUT POWER RATINGS 7 EMI 8 INPUT TRANSIENT ESD PROTECTION 8 REMOTE SENSE 8 OUTPUT...

Page 3: ...TURE SHUTDOWN 10 OPERATING ENVIRONMENT 10 SIZE AND WEIGHT 10 COOLING 11 SHOCK VIBRATION 11 PACKAGE DROP 11 RELIABILITY PREDICTION 11 MATING SIGNAL CONTROL CONNECTOR INFORMATION 11 GLOBAL SIGNALS 11 OU...

Page 4: ...UF1500 Series power supply Manual part no IMUE1500 PART NUMBER CONFIGURATION U E Z 1 _ _ _ _ _ _ _ UltraFlex Case Code Global Signals Output Module Codes SEE PAGE 14 EN55022 Level B FCC20780 Class A...

Page 5: ...ts in the product case are designed for ventilation and must not be obstructed when the product is installed and or operated G Make sure the unit is supplied only by a power source of the type indicat...

Page 6: ...quirements this terminal must be marked with as defined in IEC417 No 5019a The customer should therefore affix an adhesive label which will pass the 15 second rub test IEC950 section 1 7 15 showing th...

Page 7: ...takes and exhaust slots must not be obstructed The intake air temperature should be limited to allow the unit to operate in accordance with the thermal derating envelope of the electrical specificatio...

Page 8: ...supply to the sense points To meet specifications and output voltage set point of the output modules the sense lines must be connected to the load or locally to the power supply output terminals The r...

Page 9: ...4 8V OVP activates the internal shutdown latch of the module until the AC input power is recycled OFF to ON to clear the latch and resume normal operation once the OVP problem has been corrected OUTPU...

Page 10: ...less than 02 per o C over the ambient temperature range of 0 50 o C After 30 minute warm up NO LOAD OPERATION Operation at no load will not cause damage to the UltraFlex supply however the output volt...

Page 11: ...J2 Dual Output Connector Kit 951492 TO ORDER CONNECTORS DIRECT FROM AMP Single Output Input Connector AMP P N 87977 3 holds 10 Pins Dual Output Connector AMP P N 87977 1 holds 6 Pins Pin For Above Co...

Page 12: ...dual output module Compensates for load cable drop from power supply to sense point 25V per terminal To meet regulation the remote sense must be connected to the load or locally to the power supply R...

Page 13: ...nal causes the current share node to disconnect Maximum ratings for the output transistor are 20V 4mA Current Monitor J1 pin 9 This is an analog signal proportional to the output current 0 2VDC 2VDC a...

Page 14: ...6W 2 P 24 V 21 6 26 4 8 5A 204W 1 Q 24 V 21 6 26 4 15A 396W 2 R 24 V 21 6 26 4 25A 600W 3 S 48 V 43 2 52 8 4A 211W 1 T 48 V 43 2 52 8 8A 384W 2 U 48 V 43 2 52 8 12 5 600W 3 V 12 5 V 10 8 13 2 4 5 6 0...

Page 15: ...to output voltage setting Therefore consideration should be given to electrical energy hazards from these outputs THERMAL DERATING GUIDELINE for UltraFlex UF1500 Power Supply Series Derating UF1500 Se...

Page 16: ...REV C Page 16 of 17 OUTLINE DRAWING...

Page 17: ...REV C Page 17 of 17 LABEL CONNECTION DIAGRAM...