background image

REV C

Page 10 of 17

Dual output modules: 

<1% pk-pk. 

DYNAMIC LOAD TRANSIENT RESPONSE

A 25% step load change will result in an output deviation (overshoot or undershoot) of less
than 3% of nominal output voltage (150mV for <5V outputs, 400mV for the </= 5V 1000W
module). Output voltage will recover to within 1% of set value within 300

m

s (500us for the

</=5V 1000W module.) Slew rate not to exceed 1A/us.

DYNAMIC CROSS REGULATION

The effect of dynamic cross regulation on any fully loaded auxiliary channel for a load step
change of 25% from a 75% base value on the highest rated channel, at a slew rate not to
exceed 1A/us, shall be less than 0.1% for single output modules and less than 3% for dual
output modules. The summation of the individual module powers must not exceed the total
rated power of the UF1500. This measurement is to be performed with all other channels
loaded to 50% of rated load.

TEMPERATURE COEFFICIENT

The output voltage will change less than .02% per 

o

C over the ambient temperature range of

0-50

o

C. (After 30 minute warm-up).

NO LOAD OPERATION

Operation at no load will not cause damage to the UltraFlex supply, however the output
voltages may be outside the regulation band. A 1 Ampere preload is required on the highest
rated output for a dual output module.

OVER TEMPERATURE SHUTDOWN

The power supply is self-protected against over-temperature conditions.  A thermal shutdown
requires re-cycling of the input voltage to restore output. The fan will continue to operate
during thermal shutdown. 

OPERATING ENVIRONMENT

The power supply is designed to meet the performance parameters defined above when
operated within the following conditions:

Temperature:

0 to 50

o

 C; -20

o

C Start-Up, 30 Minutes to perform

within specifications.

Humidity:

10% - 90% Non-condensing 

Altitude:

0 – 10,000 ft. Operating

The power supply will not be damaged during transit and storage when subjected to the
following conditions: 

Temperature:

-40

o

C to +85

o

Humidity:

90% Non-condensing 

Altitude:

40,000 ft. (12Km) 

SIZE AND WEIGHT

H" x W" x L":

5”x5.125”x11”

WEIGHT:

5.7lbs. + 0.5lbs. / used slot; maximum # of slots = 10.

Summary of Contents for UF1500 Series

Page 1: ...INSTALLATION MANUAL ULTRAFLEX POWER SUPPLY UF1500 Series 3055 Del Sol Blvd San Diego CA 92154 Phone 619 575 4400 Fax 619 429 1011 P N IMUE1500 Rev C DATE February 2002...

Page 2: ...NS 5 INPUT FUSE 6 RECEIPT AND UNPACKING 6 MOUNTING REQUIREMENTS AND COOLING 7 INPUT POWER CONNECTIONS 7 AC INPUT AND OUTPUT POWER RATINGS 7 EMI 8 INPUT TRANSIENT ESD PROTECTION 8 REMOTE SENSE 8 OUTPUT...

Page 3: ...TURE SHUTDOWN 10 OPERATING ENVIRONMENT 10 SIZE AND WEIGHT 10 COOLING 11 SHOCK VIBRATION 11 PACKAGE DROP 11 RELIABILITY PREDICTION 11 MATING SIGNAL CONTROL CONNECTOR INFORMATION 11 GLOBAL SIGNALS 11 OU...

Page 4: ...UF1500 Series power supply Manual part no IMUE1500 PART NUMBER CONFIGURATION U E Z 1 _ _ _ _ _ _ _ UltraFlex Case Code Global Signals Output Module Codes SEE PAGE 14 EN55022 Level B FCC20780 Class A...

Page 5: ...ts in the product case are designed for ventilation and must not be obstructed when the product is installed and or operated G Make sure the unit is supplied only by a power source of the type indicat...

Page 6: ...quirements this terminal must be marked with as defined in IEC417 No 5019a The customer should therefore affix an adhesive label which will pass the 15 second rub test IEC950 section 1 7 15 showing th...

Page 7: ...takes and exhaust slots must not be obstructed The intake air temperature should be limited to allow the unit to operate in accordance with the thermal derating envelope of the electrical specificatio...

Page 8: ...supply to the sense points To meet specifications and output voltage set point of the output modules the sense lines must be connected to the load or locally to the power supply output terminals The r...

Page 9: ...4 8V OVP activates the internal shutdown latch of the module until the AC input power is recycled OFF to ON to clear the latch and resume normal operation once the OVP problem has been corrected OUTPU...

Page 10: ...less than 02 per o C over the ambient temperature range of 0 50 o C After 30 minute warm up NO LOAD OPERATION Operation at no load will not cause damage to the UltraFlex supply however the output volt...

Page 11: ...J2 Dual Output Connector Kit 951492 TO ORDER CONNECTORS DIRECT FROM AMP Single Output Input Connector AMP P N 87977 3 holds 10 Pins Dual Output Connector AMP P N 87977 1 holds 6 Pins Pin For Above Co...

Page 12: ...dual output module Compensates for load cable drop from power supply to sense point 25V per terminal To meet regulation the remote sense must be connected to the load or locally to the power supply R...

Page 13: ...nal causes the current share node to disconnect Maximum ratings for the output transistor are 20V 4mA Current Monitor J1 pin 9 This is an analog signal proportional to the output current 0 2VDC 2VDC a...

Page 14: ...6W 2 P 24 V 21 6 26 4 8 5A 204W 1 Q 24 V 21 6 26 4 15A 396W 2 R 24 V 21 6 26 4 25A 600W 3 S 48 V 43 2 52 8 4A 211W 1 T 48 V 43 2 52 8 8A 384W 2 U 48 V 43 2 52 8 12 5 600W 3 V 12 5 V 10 8 13 2 4 5 6 0...

Page 15: ...to output voltage setting Therefore consideration should be given to electrical energy hazards from these outputs THERMAL DERATING GUIDELINE for UltraFlex UF1500 Power Supply Series Derating UF1500 Se...

Page 16: ...REV C Page 16 of 17 OUTLINE DRAWING...

Page 17: ...REV C Page 17 of 17 LABEL CONNECTION DIAGRAM...

Reviews: