background image

INSTRUCTION / TROUBLESHOOTING MANUAL FOR MODEL A75MD

PAGE 9 OF 22

OPERATION

After the installation has been completed, the Model A75MD is ready for operation.  Be sure that the battery

charger is of the correct type for the battery to be charged.

CAREFULLY READ AND ADHERE TO ALL BATTERY AND BATTERY CHARGER INSTRUCTIONS AND SAFETY WARNINGS.

START-UP (or each time a battery of a different rated AH capacity is connected)

A. Apply AC voltage to the unit’s input terminals.

The VFD will display "Checking for Battery…..".

B. This configuration step only applies to initial install on site.

Access Customer Calibration Mode to verify charger settings. To access Customer Calibration press MODE and

UP arrow at the same time and hold for about 5 seconds.  When in the calibration mode, advance from one

function to the next by pressing the MODE button.  The MODE button is also used to advance from one digit to

the next within a function. The LAMP TEST button may be used to advance directly to the last digit within a

function. Use the UP and DOWN arrows to make selections or change settings. The LAMP TEST button is also

used to exit the Customer Calibration Mode at any time. All changes will be saved automatically. The following

settings are available to be set and/or changed by the customer (refer to flow chart on page 18):

1.

A-H  Capacity

- Allows  setting  up  the  charger  for  charging  different  A-H  capacity  range  within  a

specified   range.

A75MD Ampere Hour Ranges

CHARGER RATING IN

AMPS

LOW AH

HIGH AH

150

560

850

210

875

1200

270

1200

1500

360

1500

2000

2.

Contactor Delay –

The delay on pulling in the contactor can be selected to be 5 or 20 seconds.

3.

Enable Logging –

YES or NO.  Enables or disables the optional data logging function.

4.

Reset RTC

– This function allows the user to reset the Real Time Clock. Reset date is 01/01/2011 and

the Reset time is 00:00:01.

5.

Date

- allows the user to set the date. (Month/Day/Year)

Time

- allows the user to set the time. (Hours/Minutes/Seconds)

6.

Password –

Allows the user to set a password for entering the Customer Calibration Mode.  If YES is

selected, please enter the password and press MODE to advance.  If NO is selected, press MODE to

advance to the next screen.

7.

Serial number –

Allows the user to enter serial number of the battery charger. In case of “plug and

play” plate replacement the serial number of the battery charger may be entered.

8.

Charge count –

Allows the user to set the charge count of the battery charger. In case of “plug and

play” plate replacement the actual charge count of the battery charger may be entered.

9.

DCA Start* –

Allows the user to adjust the Start Rate current. Adjustable range is from 14.0 to 18.0

A/100AH. (0.1 increments)

10.

DCA Finish* –

Allows the user to adjust the Finish Rate current. Adjustable range is from 4.0 to 5.6

A/100AH. (0.1 increments)

11.

DCV1 REF*

- Allows the user to adjust the Constant voltage. Adjustable range is from 2.35 to 2.45

v/c. (Displayed in “volts multiplied by cells” - 0.1 increments)

12.

Battery ID

– Allows the user to enable or disable Battery ID function.

13.

Write  Settings  File

– Allows  the  user  to  save  the  settings  of  the  battery  charger  into  the  inserted

Summary of Contents for A75MD

Page 1: ...GER Digital Volt Amp Meter and Electronic Timer ECN DATE CPN 124710 21527 8 17 19536 5 12 106 BRADROCK DRIVE DES PLAINES IL 60018 1967 847 299 1188 FAX 847 299 3061 Instruction Drawing Number P25 LA75MD 1 Revision A01 Rev Date 08 17 ...

Page 2: ...llow a spark or flame in vicinity of a battery f Be extra cautious DO NOT drop metal onto a battery It might spark or short circuit the battery or cause an explosion g Remove personal metal items such as rings bracelets necklaces and watches when working with a battery A battery can produce a short circuit current high enough to weld these items causing severe burns h NEVER charge a frozen battery...

Page 3: ... the claim to La Marche Mfg may void warranty service for any physical damages reported for repair HANDLING WARNING Equipment can be very heavy and top heavy Use adequate manpower or equipment for handling Until the equipment is securely mounted care must be used to prevent the equipment from being accidentally tipped over NOMENCLATURE PLATES Each piece of La Marche Mfg Equipment shipped is identi...

Page 4: ... Constant Voltage override timer di dt monitoring in Phase 2 Constant Voltage stage dv dt monitoring in Phase 3 Finish Rate stage di dt dv dt charge shutoff Phase 3 Finish Rate 3 hr protection timer for standard charge Phase 3 Finish Rate 6 hr protection timer for equalize charge VFD Display Indicates amps volts amp hours elapsed time cooling time charge time Charger Status Ramp up Start Rate Cons...

Page 5: ...ight after the charger has successfully completed the autostart cycle and the AC contactor has closed Ramp Up Lamp This LED indicator will light after the charger starts and is in the Ramp Up stage Start Rate Lamp This LED indicator will light when the charger is charging at the Start Rate stage Constant Voltage Lamp This LED indicator will light when the charger is charging in the Constant Voltag...

Page 6: ...The automatic compensation eliminates charging problems that arise from a varying input line when charging continually or for two or three shift operations The unit is self protecting when subjected to abnormal overloading conditions It should not be necessary to make any adjustments to this charger Because of the stability of design the unit needs no periodic adjustment This along with the rugged...

Page 7: ...ge in the event that the 80 timing control does not terminate the charge before the maximum time limit of 12 hours is reached The Charger On light will turn off the Fault lamp will light and the display will indicate Override Timer If this occurs push and hold the STOP pushbutton until the Fault lamp illuminates solid red then release the STOP pushbutton The unit will reset and the lamp test will ...

Page 8: ... the flow of air through the vents is not obstructed A terminal block is provided within the unit for the AC input connections Before connecting the AC input cable check the line power with that specified on the nameplate of the unit Units with multiple AC input units have taps inside which must be set for the proper AC setting These taps are located on terminal blocks on the Power Transformers an...

Page 9: ...TING IN AMPS LOW AH HIGH AH 150 560 850 210 875 1200 270 1200 1500 360 1500 2000 2 Contactor Delay The delay on pulling in the contactor can be selected to be 5 or 20 seconds 3 Enable Logging YES or NO Enables or disables the optional data logging function 4 Reset RTC This function allows the user to reset the Real Time Clock Reset date is 01 01 2011 and the Reset time is 00 00 01 5 Date allows th...

Page 10: ...me to advance to the fourth digit and select it Press MODE again The charger will now start If an ID is not available press the MODE button four times to assign ID 0000 The charger will start Please see Data Logging Option section at the end of this manual for more information If a battery with the wrong number of cells is connected one of four messages will be displayed 1 High Battery The battery...

Page 11: ...p extinguishes I If for some reason the normal equalize or rate timers do not terminate the charge cycle in less than 12 hours the override timer will time out shut down the charger and the Fault lamp will illuminate The display will indicate Override Timer J If for some reason the unit output voltage exceeds 2 7 volts per cell for 20 sec an independent software shutdown will stop the charger The ...

Page 12: ...ycle and the battery is disconnected you may remove the USB flash drive It is not necessary to remove AC power from the charger the USB compartment is isolated from the power system Open the USB access door with a 2 Philips screwdriver and remove the USB flash drive If you are reading the USB drive underground simply copy the LAMARCHE CSV file and paste it to you desktop Do not delete or otherwise...

Page 13: ... It is written to the top of the log file to identify which charger each log belongs to Charge Count shows how many charge cycles the charger has gone through The charge count is independent of the battery and is tied to a particular charger The charge count will not reset even if a USB flash drive is removed it will increment even on new USB flash drives The charge count is almost like an odomete...

Page 14: ...erminate Time it is only the eight hours that the battery was actually under charge Charge Terminate Time similar to the start time stamp is simply the date and time that the battery was removed from the charger Cool Time is time elapsed from the end of the charge until the battery is disconnected or battery breaker is closed Using this data allows the customer to determine if the end user is lett...

Page 15: ...harge cycles 7 It is possible that no flash drive was present at the time of these charge cycles or these charge cycles have been written to another flash drive The charge count is stored in the internal memory of the charger and will increment regardless of USB status Charge Cycle 12 This is normal recharge cycle for a mostly depleted battery The battery charged for 8 hours 20 minutes before the ...

Page 16: ...low we will be adding charge cycles 4 6 that are on one flash drive to the rest of the data log on another flash drive Check to see how many charge cycles you will be adding In this example we will be adding four cycles between charge cycle 2 and charge cycle 7 Select the area under charge cycle 2 as shown above Notice that we are selecting four rows tall and enough columns wide to cover all of th...

Page 17: ... the of the log file as if it were never removed SETTINGS CSV file Below is an example of the file called SETTINGS CSV It contains information on all of the settings of the charger This file may be saved into the inserted flash drive by accessing the Customer Calibration Mode Scroll through the calibration menu until Write Settings File is displayed Select YES and wait for the file to be written L...

Page 18: ...INSTRUCTION TROUBLESHOOTING MANUAL FOR MODEL A75MD PAGE 18 OF 22 FLOW CHART ...

Page 19: ...T power transformer If fuse is good problem could be in the SCR Diode module SEE SCR SCR TROUBLESHOOTING GUIDE 5 Replace Plug and Play Assembly Problem Blown DC fuse 1 Make sure the correct type of fuse is being used 2 Check all connections to DC fuse to be certain they are tight 3 Check polarity of output cables and output connector 4 Check SCR SCR modules and diode SD4 for shorts SEE SCR SCR MOD...

Page 20: ...ly plugs 4 Measure the resistance from anode to cathode of each SCR This measurement should read as high resistance If the leads are reversed the measurement should also read as high resistance 5 Measure the resistance of the diode module from anode to cathode When forward biased resistance should read low when reverse biased resistance should read high 6 If the resistance readings do not match th...

Page 21: ...Maintenance Procedure Yearly 1 Blow out charger with a low pressure air hose 2 Make sure all connections are tight 3 Perform a visual check on all internal components 4 Check front panel meters for accuracy 5 Check magnetics components and wiring for signs of excessive heat ...

Page 22: ... purchaser elects not to return the equipment to the factory and wishes a factory service representative to make adjustments and or repairs at the equipment location La Marche s field service labor rates will apply A purchase order to cover the labor and transportation cost is required prior to the deployment of the service representative In accepting delivery of the equipment the purchaser assume...

Reviews: