background image

INSTRUCTION / TROUBLESHOOTING MANUAL FOR MODEL A75MD

PAGE 22 OF 22

MANUFACTURER’S WARRANTY

All La Marche Manufacturing Co. equipment has been thoroughly tested and found to be in proper operating condition upon

shipment  from the  factory  and  is  warranted  to  be  free  from  any  defect  in  workmanship  and  material  that  may  develop

within  one  year  from  date  of  purchase.    In  addition  to  the  standard  one  (1)  year  warranty,  La  Marche  warrants  its

magnetics on a parts replacement basis only for four (4) more years under normal use.

Any part or parts of the equipment (except fuses, DC connectors and other wear-related items) that prove defective within

a one (1) year period shall be replaced without charge providing such defect, in our opinion, is due to faulty material or

workmanship and not caused by tampering, abuse, misapplication or improper installation.  Magnetics are warranted for five

(5) years after date of purchase.  During the last four (4) years of this five (5) year warranty period, the warranty covers

parts replacement only, and no labor or other services are provided by La Marche, nor is La Marche obligated to reimburse

the owner or any other person for work performed.

Should a piece of equipment require major component replacement or repair during the first year of the warranty period,

these can be handled in one of two ways:

1. The equipment can be returned to the La Marche factory to have the inspections, parts replacements

and testing performed by factory personnel.  Should it be necessary to return a piece of equipment or

parts to the factory, the customer or sales representative must obtain authorization from the factory.

If upon inspection at the factory, the defect was due to faulty material or workmanship, all repairs will

be made at no cost to the customer during the first year.  Transportation charges or duties shall be

borne by purchaser.

2.  If  the  purchaser  elects  not  to  return  the  equipment  to  the  factory  and  wishes  a  factory  service

representative to make adjustments and/or repairs at the equipment location, La Marche's field service

labor rates will apply.  A purchase order to cover the labor and transportation cost is required prior to

the deployment of the service representative.

In  accepting  delivery  of  the  equipment,  the  purchaser  assumes  full  responsibility  for  proper  installation,  installation

adjustments  and  service arrangements.  Should minor adjustments  be required, the local La Marche sales representative

should be contacted to provide this service only.

All  sales  are  final.    Only  standard  LaMarche  units  will  be  considered  for  return.    A  25%  restocking  fee  is  charged  when

return is factory authorized.  Special units are not returnable.

In no event shall La Marche Manufacturing Co. have any liability for consequential damages, or loss, damage or expense

directly or indirectly arising from the use of the products, or any inability to use them either separately or in combination

with other equipment or materials, or from any other cause.  In addition, any alterations of equipment made by anyone

other than La Marche Manufacturing Co. renders this warranty null and void.

La  Marche  Manufacturing  Co.  reserves  the  right  to  make  revisions  in  current  production  of  equipment,  and  assumes  no

obligation to incorporate these revisions in earlier models.

The  failure  of  La  Marche  Manufacturing  Co.  to  object  to  provisions  contained  in  customers'  purchase  orders  or  other

communications shall not be deemed a waiver of the terms or conditions hereof, nor acceptance of such provisions.

The  above  warranty  is  exclusive,  supersedes  and  is  in  lieu  of  all  other  warranties,  expressed  or  implied,  including  any

implied warranty of merchantability or fitness.  No person, agent or dealer is authorized to give any warranties on behalf of

the Manufacturer, nor to assume for the Manufacturer any other liability in connection with any of its products unless made

in writing and signed by an official of the manufacturer.

Summary of Contents for A75MD

Page 1: ...GER Digital Volt Amp Meter and Electronic Timer ECN DATE CPN 124710 21527 8 17 19536 5 12 106 BRADROCK DRIVE DES PLAINES IL 60018 1967 847 299 1188 FAX 847 299 3061 Instruction Drawing Number P25 LA75MD 1 Revision A01 Rev Date 08 17 ...

Page 2: ...llow a spark or flame in vicinity of a battery f Be extra cautious DO NOT drop metal onto a battery It might spark or short circuit the battery or cause an explosion g Remove personal metal items such as rings bracelets necklaces and watches when working with a battery A battery can produce a short circuit current high enough to weld these items causing severe burns h NEVER charge a frozen battery...

Page 3: ... the claim to La Marche Mfg may void warranty service for any physical damages reported for repair HANDLING WARNING Equipment can be very heavy and top heavy Use adequate manpower or equipment for handling Until the equipment is securely mounted care must be used to prevent the equipment from being accidentally tipped over NOMENCLATURE PLATES Each piece of La Marche Mfg Equipment shipped is identi...

Page 4: ... Constant Voltage override timer di dt monitoring in Phase 2 Constant Voltage stage dv dt monitoring in Phase 3 Finish Rate stage di dt dv dt charge shutoff Phase 3 Finish Rate 3 hr protection timer for standard charge Phase 3 Finish Rate 6 hr protection timer for equalize charge VFD Display Indicates amps volts amp hours elapsed time cooling time charge time Charger Status Ramp up Start Rate Cons...

Page 5: ...ight after the charger has successfully completed the autostart cycle and the AC contactor has closed Ramp Up Lamp This LED indicator will light after the charger starts and is in the Ramp Up stage Start Rate Lamp This LED indicator will light when the charger is charging at the Start Rate stage Constant Voltage Lamp This LED indicator will light when the charger is charging in the Constant Voltag...

Page 6: ...The automatic compensation eliminates charging problems that arise from a varying input line when charging continually or for two or three shift operations The unit is self protecting when subjected to abnormal overloading conditions It should not be necessary to make any adjustments to this charger Because of the stability of design the unit needs no periodic adjustment This along with the rugged...

Page 7: ...ge in the event that the 80 timing control does not terminate the charge before the maximum time limit of 12 hours is reached The Charger On light will turn off the Fault lamp will light and the display will indicate Override Timer If this occurs push and hold the STOP pushbutton until the Fault lamp illuminates solid red then release the STOP pushbutton The unit will reset and the lamp test will ...

Page 8: ... the flow of air through the vents is not obstructed A terminal block is provided within the unit for the AC input connections Before connecting the AC input cable check the line power with that specified on the nameplate of the unit Units with multiple AC input units have taps inside which must be set for the proper AC setting These taps are located on terminal blocks on the Power Transformers an...

Page 9: ...TING IN AMPS LOW AH HIGH AH 150 560 850 210 875 1200 270 1200 1500 360 1500 2000 2 Contactor Delay The delay on pulling in the contactor can be selected to be 5 or 20 seconds 3 Enable Logging YES or NO Enables or disables the optional data logging function 4 Reset RTC This function allows the user to reset the Real Time Clock Reset date is 01 01 2011 and the Reset time is 00 00 01 5 Date allows th...

Page 10: ...me to advance to the fourth digit and select it Press MODE again The charger will now start If an ID is not available press the MODE button four times to assign ID 0000 The charger will start Please see Data Logging Option section at the end of this manual for more information If a battery with the wrong number of cells is connected one of four messages will be displayed 1 High Battery The battery...

Page 11: ...p extinguishes I If for some reason the normal equalize or rate timers do not terminate the charge cycle in less than 12 hours the override timer will time out shut down the charger and the Fault lamp will illuminate The display will indicate Override Timer J If for some reason the unit output voltage exceeds 2 7 volts per cell for 20 sec an independent software shutdown will stop the charger The ...

Page 12: ...ycle and the battery is disconnected you may remove the USB flash drive It is not necessary to remove AC power from the charger the USB compartment is isolated from the power system Open the USB access door with a 2 Philips screwdriver and remove the USB flash drive If you are reading the USB drive underground simply copy the LAMARCHE CSV file and paste it to you desktop Do not delete or otherwise...

Page 13: ... It is written to the top of the log file to identify which charger each log belongs to Charge Count shows how many charge cycles the charger has gone through The charge count is independent of the battery and is tied to a particular charger The charge count will not reset even if a USB flash drive is removed it will increment even on new USB flash drives The charge count is almost like an odomete...

Page 14: ...erminate Time it is only the eight hours that the battery was actually under charge Charge Terminate Time similar to the start time stamp is simply the date and time that the battery was removed from the charger Cool Time is time elapsed from the end of the charge until the battery is disconnected or battery breaker is closed Using this data allows the customer to determine if the end user is lett...

Page 15: ...harge cycles 7 It is possible that no flash drive was present at the time of these charge cycles or these charge cycles have been written to another flash drive The charge count is stored in the internal memory of the charger and will increment regardless of USB status Charge Cycle 12 This is normal recharge cycle for a mostly depleted battery The battery charged for 8 hours 20 minutes before the ...

Page 16: ...low we will be adding charge cycles 4 6 that are on one flash drive to the rest of the data log on another flash drive Check to see how many charge cycles you will be adding In this example we will be adding four cycles between charge cycle 2 and charge cycle 7 Select the area under charge cycle 2 as shown above Notice that we are selecting four rows tall and enough columns wide to cover all of th...

Page 17: ... the of the log file as if it were never removed SETTINGS CSV file Below is an example of the file called SETTINGS CSV It contains information on all of the settings of the charger This file may be saved into the inserted flash drive by accessing the Customer Calibration Mode Scroll through the calibration menu until Write Settings File is displayed Select YES and wait for the file to be written L...

Page 18: ...INSTRUCTION TROUBLESHOOTING MANUAL FOR MODEL A75MD PAGE 18 OF 22 FLOW CHART ...

Page 19: ...T power transformer If fuse is good problem could be in the SCR Diode module SEE SCR SCR TROUBLESHOOTING GUIDE 5 Replace Plug and Play Assembly Problem Blown DC fuse 1 Make sure the correct type of fuse is being used 2 Check all connections to DC fuse to be certain they are tight 3 Check polarity of output cables and output connector 4 Check SCR SCR modules and diode SD4 for shorts SEE SCR SCR MOD...

Page 20: ...ly plugs 4 Measure the resistance from anode to cathode of each SCR This measurement should read as high resistance If the leads are reversed the measurement should also read as high resistance 5 Measure the resistance of the diode module from anode to cathode When forward biased resistance should read low when reverse biased resistance should read high 6 If the resistance readings do not match th...

Page 21: ...Maintenance Procedure Yearly 1 Blow out charger with a low pressure air hose 2 Make sure all connections are tight 3 Perform a visual check on all internal components 4 Check front panel meters for accuracy 5 Check magnetics components and wiring for signs of excessive heat ...

Page 22: ... purchaser elects not to return the equipment to the factory and wishes a factory service representative to make adjustments and or repairs at the equipment location La Marche s field service labor rates will apply A purchase order to cover the labor and transportation cost is required prior to the deployment of the service representative In accepting delivery of the equipment the purchaser assume...

Reviews: