background image

Cleaning Kit optional

FCY2

FCY3

FC4C

FCY5

FCY6

A

2” Thread M

3” Flange

3” Flange

3” Flange

3” Flange

B

450 mm.

500 mm.

700 mm.

700 mm.

730 mm.

C

560 mm.

570 mm.

575 mm.

600 mm.

1.025 mm.

D

660 mm.

825 mm.

840 mm.

885 mm.

995 mm.

E

350 mm.

500 mm.

500 mm.

650 mm.

900 mm.

F

¾

” 

Thread M.

¾

” 

Thread M.

¾

” 

Thread M.

¾

” 

Thread M.

¾

” 

Thread M.

Net Weight

16 Kg.

24 Kg.

33,5 Kg.

41 Kg.

70,5 Kg.

Gross Weight

17 Kg.

26 Kg.

35,5 Kg.

43,5 Kg.

71 Kg.

Package 

volume 

0.085 m

3

0.109 m

3

0.109 m

3

0.109 m

3

0.0310 m

3

Filtration 

Surface 

1.071 m

3

1.590 m

3

2.312 m

3

3.116 m

3

5.404 m

3

Centrifugal Screen Filters

System

Filtration produced by the physical retention of particles larger than the orifices of the thermosoldered stainless steel 
mesh. This stainless steel mesh is located in a cylindrical structure of drilled PVC. In order to obtain more surface of 
contact between the mesh and the water, another mesh of plastic is sandwiched between the PVC cylinder and the 
stainless steel mesh.
Large filtration area and minimum head loss.
High resistance to the effects that are produced by the differential pressure.
These filters have a baffle plate with tangential stream in order to produce the centrifugation, making that the particles 
are pulled by the weight diference to the accumulator tank.

Installation

In horizontar or vertical way, keeping always downwards the accumulator tank.
Verify the water flow direction.
Place the plug number on the shield in order to keep clean the cartridge and with 0,5Kg/cm² of head loss (see schemes).  
Check that a water regression, that can break or extract the screen,doesn’t exist. If it’s necessary, put a non-return 
valve and vents. 
It’s very important that the user periodically verifies the screen wear condition. For it, it’s necessary to disassemble the 
cartridge and replace it before the screen fiber wear.
Place the stravenge valve or the automatic kit on the accumulator tank (not supplied).
If you want to see the head loss, instal two presure gauges (not supplied).
Verify that stones or pricking elements can´t get into and break the screen.

Cleaning

It is carried out by periodic scavenge of the accumulator tank, where a non supplied valve has to be threaded. For a 
greater confort there is an automatic stravenge kit optional.
When it is observed that the head loss is excessive, it is advisable to extract the cartridge and cleaning it by hand.

Applications

ecommeded for the use with any type of water, specially water containing fine sand in suspension.
It eliminates the particles in suspensión taking advantage of the centrifugal effect caused by the specially designed inlet 
to the filte-ring cartridge.
Ideal as a pre-filter for sand tanks.
Economic system that can in many cases replace the clasic hydrocyclone, thanks to its ability to separate heavy particles.
Avoid use where the water to be filtered carries stones and heavy sand load.
Minimun headloss across the filter of 5 metres is required for effective centrifugal action.
For using it with water carrying excess sand, a hydro-cyclone in front of the filter has to be placed.
A set of rubber plugs are supplied in order to generate a loss of load in the filter of 0,5Kg.

7

EN

    

ENGLISH 

Centrifugadores

Summary of Contents for FCY2

Page 1: ...tros Centrifugadores Met licos de malla Centrifugal Filters Metallic Screen Filters Filtres Centrifugateur Filtres m talliques Tamis Centrifugadores Filtros Metalico de Malla Metallic Screen Filters F...

Page 2: ...Fernando Lama S L Noviembre 2017 Gelves Sevilla Espa a Versi n 1 0...

Page 3: ...y and to obtain the best results Proper maintenance carried out by qualified personnel will make the use of Lama filtration systems more profitable and satisfactory 1 Explanation of functioning and co...

Page 4: ...a de tablas Da os a terceros robos o vandalismo RECLAMACIONES A LA GARANT A Este producto ha sido sometido a pruebas en f brica y ha cumplido las normas de calidad Si aun as tuviera o encontrara alg n...

Page 5: ...DE GARANTIE Les op rations de maintenance ou nettoyage p riodiques La d t rioration due la fatigue l abrasion ou aux hautes temp ratures Les tensions lectriques sup rieures ou inf rieures celles qui...

Page 6: ...man metros no suministrados Verificar que no entren piedras o elementos punzantes que puedan romper la malla Limpieza Se realiza mediante purgas peri dicas del dep sito acumulador al que hay que rosc...

Page 7: ...Check that a water regression that can break or extract the screen doesn t exist If it s necessary put a non return valve and vents It s very important that the user periodically verifies the screen...

Page 8: ...fier que n entrent pas des pierres ou l ments pointus qui peuvent briser la maille Nettoyage Se realise moyennant purges p riodiques du d p t accumulateur auquel il faut viser une vanne non fourni Pou...

Page 9: ...cleaning centrifugal metallic filters with respect to the number of orifices covered each of them with 0 5 Kg cm 7 12 psi of differential pressure D bit en fonction du nombre d orifices recouvert pour...

Page 10: ...era Cover TC3C 1 TC3C 1 TC4C 1 6 Palometa First cross piece P230 1 P230 1 P280 1 7 Cruceta Second cross piece CR18 1 CR18 1 CR18 1 FCY5 N Descripci n Description Cod Uni 1 Cuerpo Filtro Body CMY5 1 2...

Page 11: ...FRAN AIS ENGLISH ESPA OL Filtros Metalico de Malla Metallic Screen Filters Filtres m talliques Tamis Met licosMalla...

Page 12: ...de los hilos de la malla Colocar la v lvula de purga o el kit autom tico sobre el dep sito acumulador no suministrado Si se desea ver la p rdida de carga instalar dos man metros no suministrados Verif...

Page 13: ...250 825 600 40 5 41 0 158 2 940 FMY5 6 Brida 730 320 986 923 69 5 70 5 0 269 5 032 FMY6 8 Brida 900 430 1 340 1 250 100 100 5 0 61 10 781 FMY8 10 Brida 1 000 430 1 525 1 430 105 105 5 1 160 13 028 FM...

Page 14: ...avenge valve or the automatic kit on the accumulator tank not supplied If you want to see the head loss instal two presure gauges not supplied Verify that stones or pricking elements can t get into an...

Page 15: ...700 250 825 600 36 5 38 5 0 158 2 940 FMY4 5 Flange 700 250 825 600 40 5 41 0 158 2 940 FMY5 6 Flange 730 320 986 923 69 5 70 5 0 269 5 032 FMY6 8 Flange 900 430 1340 1250 100 100 5 0 61 10 781 FMY8...

Page 16: ...d monter la cartouche et la remplacer avant que les files du tamis non us Placer la vanne de purge ou la kit automatique sur la cuve accumulatrice non fournie Si l on souhaite v rifier la perte de ch...

Page 17: ...0 30 5 32 5 0 89 2 207 FM4B 4 Bride 700 250 825 600 36 5 38 5 0 158 2 940 FMY4 5 Bride 700 250 825 600 40 5 41 0 158 2 940 FMY5 6 Bride 730 320 986 923 69 5 70 5 0 269 5 032 FMY6 8 Bride 900 430 1340...

Page 18: ...6 Palometa First cross piece P230 1 P230 1 7 Cruceta Second cross piece CR18 1 CR18 1 FMY2 FMY3 FM4B N Descripci n Description Cod Uni Cod Uni Cod Uni 1 Cuerpo Filtro Body CMY2 1 CMY3 1 CM4B 1 2 Junt...

Page 19: ...M8 1 7 Arandela Washer M16 ARAN 3 ARAN 3 ARAN 3 ARAN 4 ARAN 4 8 Maneta Handle MANE 3 MANE 3 MANE 3 MANE 4 MANE 4 FML4 FML6 FML8 F10L F12L N Descripci n Description Cod Uni Cod Uni Cod Uni Cod Uni Cod...

Page 20: ...ement _____________________________________________________________ The identified filter station with a detailed description included in the manual user guide meets the requirements of the directive...

Page 21: ...Apreciado cliente Dear client Cher client SU FILTRO NECESITA MANTENIMIENTO YOUR FILTER NEEDS MAINTENANCE LE FILTRE A BESOIN D ENTRETIEN...

Page 22: ...Apreciado cliente Dear client Cher client SU FILTRO NECESITA MANTENIMIENTO YOUR FILTER NEEDS MAINTENANCE LE FILTRE A BESOIN D ENTRETIEN...

Page 23: ......

Page 24: ......

Reviews: