S

ERIAL 

I

NTERFACE

 

 

CL4790 Serial Interface

  

 

Hardware Flow Control

  

The CL4790 supports the following protocols, which are separate products: 

 

RS232 

 

RS485 

 

CL4790 Serial Interface 

RS232 

 

Figure 2: CL4790-RS232 

RS232 is a single-ended data transmission protocol. The RS232 signals are represented by voltage levels with 
respect to a system common (power/logic ground). The “idle” state (MARK) has the signal level negative with 
respect to common, and the “active” state (SPACE) has the signal level positive with respect to common. 

Table 3: CL4790 DB9 Male Connector Pinout (as defined at the CL4790) 

DB9 Pin 

Signal Name 

Description 

Direction 

DCD 

Data Carrier Detect 

Out 

 

TXD (RXD with respect to DTE) 

Transmit Data 

Data Out to Host 

RXD (TXD with respect to DTE) 

Receive Data 

Data In to CL4790 

DTR 

Data Terminal Ready  In 

GND 

Ground 

DSR 

Data Set Ready 

Out 

RTS 

Request to Send 

In 

CTS 

Clear to Send 

Out 

RI 

Ring Indicator 

Out 

 

 

 

Summary of Contents for CL4790

Page 1: ...CL4790 HARDWARE INTEGRATION GUIDE VERSION 3 0 Americas 1 800 492 2320 Europe 44 1628 858 940 Hong Kong 852 2923 0610 www lairdtech com ramp...

Page 2: ...posure Installation Instructions WARNING To satisfy FCC RF exposure requirements for mobile transmitting devices this equipment must be professionally installed such that the end user is prevented fro...

Page 3: ...790 REVISION HISTORY Version Date Changes Approved By 1 0 Initial Release Chris Downey 1 1 Changes and Revisions Chris Downey 2 0 02 Aug 2013 Major changes and revisions updated format and data Chris...

Page 4: ...940 Hong Kong 852 2923 0610 www lairdtech com ramp 4 CONN HIG_CL4790 CONTENTS Revision History 3 Contents 4 CL4790 RF Transceiver 5 Overview 5 Features 5 Detailed Specifications 6 Status LEDs 7 Seria...

Page 5: ...es several transceiver pairs to carry on simultaneous conversations on the same network CL4790s implement a proprietary communication protocol to provide secure data transmissions Using FHSS technolog...

Page 6: ...Canada 915 928 MHz US Canada Australia RF Data Rate 76 8 Kbps fixed Host Data Throughput 20 5 Kbps maximum RF Technology Frequency Hopping Spread Spectrum FHSS EEPROM write cycles 20000 Hop Period 50...

Page 7: ...ecautions when handling this device to prevent permanent damage External ESD protection is required to protect this device from damage as required to pass IEC 61000 4 2 or ISO 10605 based on end syste...

Page 8: ...re represented by voltage levels with respect to a system common power logic ground The idle state MARK has the signal level negative with respect to common and the active state SPACE has the signal l...

Page 9: ...hrough serial cable When interfacing two DCE or two DTE devices together a null modem cable or crossover cable is required to swap the pins and convert the signals accordingly Figure 3 DTE to DCE inte...

Page 10: ...que addresses and can send addressed packets to specific nodes Because the bus is half duplex no two nodes should try to talk at the same time The CL4790 does not have a RS485 address therefore it tra...

Page 11: ...e potential to be lost due to buffer overflow Ready to Send RTS is an input to the CL4790 from the OEM host When the RTS Enable option is selected in the software configuration of the CL4790 the trans...

Page 12: ...RMM 915 Nearson 1 2 Wave Dipole 2 X 0600 00024 S467AH 915 Nearson 1 2 Wave Dipole 2 X 0600 00027 S467AH 915R Nearson 1 2 Wave Dipole 2 X 0600 00028 S161AH 915R Nearson 1 2 Wave Dipole 2 5 X 0600 00029...

Page 13: ...3 CONN HIG_CL4790 RELATED DOCUMENTS AND FILES The following additional CL4790 technical documents are also available from the Laird RAMP ConnexLink modules product page under the Documentation tab Pro...

Reviews: