5HP Dust Collector Manual
12
DO NOT EXPOSE THE MACHINE TO RAIN OR OPERATE THE
MACHINE IN DAMP
LOCATIONS.
MOTOR SPECIFICATIONS
Your machine is wired for 220 volts, 60 HZ alternating current. Before connecting the
machine to the power source, make sure the switch is in the "OFF" position.
GROUNDING INSTRUCTIONS
THIS MACHINE MUST BE GROUNDED WHILE IN USE TO PROTECT THE OPERATOR
FROM ELECTRIC SHOCK.
1
. This appliance must be connected to a grounded metal, permanent wiring system; or
an equipment-grounding conductor must be run with the circuit conductors and connected
to the equipment-grounding terminal or lead on the appliance.
The installer, such as a qualified electrician, cut (or bend over) and insulate the grounding
conductor from a field wiring supply cable.
In the event of certain types of malfunctions or breakdowns, grounding provides a path of
least resistance for electric current
—
in order to reduce the risk of electric shock.
Improper connection of the equipment-grounding wire can result in a risk of electric
shock. The wire with green insulation (with or without yellow stripes) is the equipment-
grounding wire. If repair or replacement of the power cord or plug is necessary, do not
connect the equipment-grounding wire to a live (current carrying) terminal.
Check with a qualified electrician or service personnel if you do not understand these
grounding requirements, or if you are in doubt about whether the tool is properly
grounded. If you ever notice that a cord or plug is damaged or worn, disconnect it from
power, and immediately replace it with a new one.
Full Load amperage Draw
Amp draw at 220V (prewired).................. 1 8 . 5 Amps
Power Supply Circuit Requirements
The power source circuit for your machine must be g r o u n d e d and r a t e d f o r the
am perage given below. Never replace a circuit breaker on an existing circuit with
one of higher amperage without consulting a qualified electrician to ensure
compliance with wiring codes.
If you are unsure about the wiring codes in your
area or you plan to connect your machine to a shared circuit, consult a qualified
electrician.
Circuit Size (220V).................................. 30 Amp min.