JX|8 Sheartec:II Jointer \ Electrical Safety
AND CONNECTED TO POWER SUPPLY.
ELECTROCUTION, FIRE, SHOCK, OR EQUIPMENT DAMAGE MAY OCCUR IF MACHINE IS NOT PROPERLY GROUNDED
MACHINE IN WET OR DAMP CONDITIONS.
RUNNING ON A DIFFERENT VOLTAGE THAN STATED BELOW WILL DAMAGE THE MACHINE. NEVER RUN THE
WARNING!
PHASE
1PH
PLUG/RECEPTACLE
220V
Electrical Safety
Motor Specifications
The typical main motor is 3 HP and is wired for 220 Volt, Single-Phase, 60 HZ, AC current with a (NEMA 6-
20P) plug for North America. Confirm your motor electrical configuration and plug before connecting
power! Before connecting the machine to the power source, make sure the starter and switches are in
the "OFF" position.
Power Supply
A separate electrical circuit should be used for each machine. This circuit should not be less than the wiring
listed below and should be protected with an appropriate circuit breaker based on the total running and
start-up amperage's (listed below). Extension cords are not recommended. But, i f an extension cord is
used, use only 3-wire extension cords which have 3-prong grounding type plugs and matching receptacle
which will accept the
machine’s
plug.
MJ8X72E-0130
VOLTAGE
220V
HERTZ
60Hz
Below are RECOMMENDATIONS to be used for this machine based on the above
information. Variables that may affect this are:
Actual voltage supplied to the machine
Electrical code that must be met in your local province.
An electrician will verify that all the demands are met to properly wire the machine. If you have
absolutely any doubt when wiring this machine - please consult with a qualified electrician.
WIRING (Gauge)
See Jacket Printing
If this information is different than what is stated on the Motor Specification Plate - omit this information. It
is possible that the documentation is outdated to a machine change - such as a different motor
. Always
check the motor plate prior to any wiring.
If any doubts, please consult a certified electrician.
Know when to use a time delay fuse! AKA Slow blow fuse. Generally, if the motor uses a start capacitor, a
time delay fuse is required. This type of fuse will not trip with the initial amperage needed
20 Amp
CIRCUIT BREAKER/FUSE
12 Amp
FULL LOAD AMPERAGE
Summary of Contents for Sheartec II JX 8
Page 1: ...JX 8 Sheartec II Jointer Owner s Manual Owner s Manual MJ8X72P 0130...
Page 21: ...JX 8 Sheartec II Jointer Setup Assembling 21 FIGURE 11 Fence Stope Locks...
Page 36: ...34 JX 8 Sheartec II Jointer Wiring JX 8 ShearTec II MJ8X72E 0130...
Page 37: ...JX 8 Sheartec II Jointer JX8 Sheartec II Parts 35 JX8 Sheartec II Parts Tables Components...
Page 38: ...36 JX 8 Sheartec II Jointer Wiring Cutterhead Drivetrain...
Page 39: ...JX 8 Sheartec II Jointer JX8 Sheartec II Parts 37 Fence...
Page 40: ...38 JX 8 Sheartec II Jointer JX8 Sheartec II Parts Stand Motor...