27
TROUBLESHOOTING
Description of
Symptoms
Possible Cause
Corrective Action
Machine will not start
1. Fuse blown or circuit
breaker tripped
2. Cord damaged
3. Not connected to
power source
4. Connected to wrong
voltage
5. Overload tripped
1. Replace fuse or reset
circuit breaker
2. Have cord replaced
3. Check connection
4. Check voltage
5. press reset
switch on control
panel
Cutterhead does not
come up to speed
1. Low current
2. Motor not
connected to
correct voltage
1. Contact local
electric
company
2. Refer to motor
nameplate for correct
voltage
Workpiece stops when
feeding
1. Too much
material being
removed in one
pass
2. Insufficient
pressure on in-
feed or out-feed
rollers
1. Reduce the
amount of
material being
removed
2. Increase pressure on
in-feed or out-feed
rollers
Summary of Contents for PX12