background image

ENGLISH

3

 

• Do not use this pump in swimming pools or other situations where people are immersed.

 

• This pump is suitable for use in water temperatures up to 95° F / 35° C.

 

• Do not use this pump with inflammable, corrosive, explosive (e.g. petrol, fuel, diluents) or drinkable l 

   liquids, greases, oils or foodstuffs.
8.  Do not install or store the appliance where it will be exposed to the weather or to temperatures below freezing.  
 

Remove and store the pump in a sheltered place.  Shelter pump away from direct sunlight. The materials  

 

have high stability to sunlight but direct rays may overheat the motor and speed up insulator aging.

9. 

IMPORTANT

 - Make sure that the pump is securely installed before operating it. Do not allow the pump  

 

to run dry. The pump must be immersed in water completely. This pump must never operate outside of water.

 

Before starting the pump make sure that:

 

• The voltage and frequency specified on the pump’s nameplate coincide with those of the available power 

 

  supply; these pumps are designed for 115 Volt – 60 Hz operation. 

 

• There are no signs of damage to the pump or its power cord; 

 

• The electric connection is made in a dry place, protected against any risk of flooding; 

 

• Conformity with local and State electric codes is mandatory. The National Electric Code requires that a  

 

  ground fault circuit interrupter (GFCI) be used in the branch circuit supplying sump, utility, effluent and  

 

  all fountain pumps, pool pumps and other pond equipment. Consult a licensed electrician or your    

 

  power company if in doubt. 

 

• The float must be able to move freely while the pump is in operation.

 

• It is absolutely essential to prevent any risk of the pump freezing. In the event of freezing temperatures,  

 

  remove the pump from the liquid, empty it and keep it in a place where it cannot freeze.

 

• Periodically, it is advisable to make sure that no dirt (leaves, sand, etc.) has accumulated in the collection  

 

  trap or around the suction grid.

10.  If an extension cord is necessary, ensure connection is watertight and dust proof. A cord with proper rating  
 

should be used. A cord rated for less amperes or watts than the appliance rating may overheat. Any exten 

 

sion cords must comply with requirements of the DIN VDE Standard 0620. Care should be taken to arrange  

 

the cord so that it will not be tripped over or pulled. The connection should be carried out by a qualified  

 

electrical installer. 

 

Automatic operation:

 

The floating switch starts and stops the pump automatically. The water level that prompts the starting and  

 

stopping of the pump can be adjusted by changing the length of cable between the holder and the float.

 

The length of cable for the float must never be shorter than ½”.

 

Manual operation:

 

a)   The floating switch must be lifted in order to start pumps with a float.

 

b)   For pumps without a float, insert the plug.

11. 

IMPORTANT

 – Supply electrical power through a Residual Current Device (RCD or Ground Fault Current  

 

Interrupter) with rated residual current not exceeding 30 mA.

12. 

WARNING

 – RISK OF ELECTRIC SHOCK – This pump is supplied with a grounding-type or attachment plug.

 

To reduce the risk of electric shock:

 

• The electric connection should be made in a dry place, protected against any risk of flooding;

 

• Be certain that it is connected only to a properly grounded, grounding-type receptacle

Jolie 

Products, 

Inc

Summary of Contents for MaxDrive PT201

Page 1: ...assins de jardin et ornements aquatiques Bomba sumergible para estanques y decoraciones acu ticas Beautifully simple water gardening Am nager un bassin de jardin merveilleusement simple Perfecto para...

Page 2: ...J o l i e P r o d u c t s I n c...

Page 3: ...lations Ejemplos de diferentes instalaciones Designed to work in both vertical and horizontal applications Con ue pour fonctionner la verticale ou l horizontale Dise ada para funcionar en aplicaciones...

Page 4: ...the cord 3 This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given sup...

Page 5: ...ile the pump is in operation It is absolutely essential to prevent any risk of the pump freezing In the event of freezing temperatures remove the pump from the liquid empty it and keep it in a place w...

Page 6: ...d the more work you are asking your pump to do and therefore the more powerful it has to be It s a good idea to choose one with a capacity slightly greater than your initial needs especially since you...

Page 7: ...h Check that fluids being pumped are not too dense causing pump to overheat Ensure water temperature does not exceed 95 F 35 C Check strainer and impellor for obstructions CLEANING INTAKE STRAINER IMP...

Page 8: ...de cet appareil ne peut pas tre remplac si le cordon est endommag il faut jeter l appareil Ne jamais couper le cordon 3 Cet appareil ne doit pas tre utilis par des personnes y compris des enfants aux...

Page 9: ...l NEC exige qu un disjoncteur de fuite de terre GFCI soit install sur le circuit de d rivation alimentant toute pompe de puisard d eaux d gout d effluents de fontaine de piscine et d autres appareils...

Page 10: ...ent attendu de l appareil Servira t il seulement la circulation de l eau ou fera t il circuler l eau dans un filtre pour cascade un st rilisateur clarificateur UV une cascade ou un ornement aquatique...

Page 11: ...l eau qui entre dans la pompe est trop dense et pourrait causer la surchauffe de l appareil S assurer que la temp rature de l eau ne d passe pas 35 C 95 F V rifier si la cr pine d admission et l impul...

Page 12: ...sensoriales o mentales reducidas o personas sin experiencia ni conocimiento a menos que sean supervisadas o hayan recibido instrucciones sobre el uso del aparato de parte de una persona responsable d...

Page 13: ...riesgo de que la bomba se congele En caso de haber temperaturas bajo cero extraiga la bomba del l quido vac ela y mant ngala en un lugar donde no pueda congelarse Se recomienda asegurarse peri dicamen...

Page 14: ...trabajo le demandar a la bomba por lo tanto deber ser m s potente Es una buena idea elegir una bomba con una capacidad apenas mayor de lo que pretende al comienzo especialmente si desea agregar acceso...

Page 15: ...mo para causar el sobrecalentamiento de la bomba Procure que la temperatura del agua no supere los 35 C 95 F Verifique que el filtro o el impulsor no presenten obstrucciones LIMPIEZA DEL IMPULSOR FILT...

Page 16: ...3 4 A 7 6 A 10 A 11 2 A Puissance 260 W 370 W 820 W 1 000 W 1 100 W Nombre de chevaux vapeur 0 25 0 3 0 5 0 75 1 Longueur du cordon d alimentation 6 m 6 m 6 m 6 m 6 m Diam tre de sortie d eau 32 mm 32...

Page 17: ...a tarjeta de registro Si lo prefiere puede registrarse a trav s de nuestro sitio web www hagen com Mr Sr Mrs Sra Miss Srta Ms First Name Nombre Last Name Apellido PLEASE PRINT LETRA DE IMPRENTA DD MM...

Page 18: ..._______________________________ _________________________________________________________________________________________________ ______________________________________________________________________...

Page 19: ..._______________________________ _________________________________________________________________________________________________ ______________________________________________________________________...

Page 20: ...a Rolf C Hagen Inc Montreal QC H9X 0A2 U S A Rolf C Hagen U S A Corp Mansfield MA 02048 Printed in Italy Laguna and Hagen are registered trademarks of Rolf C Hagen Inc www lagunaponds com J o l i e P...

Reviews: