background image

ENGLISH

2

Submersible Pond and Water Feature Pumps

For freshwater and submersible use only

Read thoroughly prior to installation and operation

 

IMPORTANT SAFETY INSTRUCTIONS

WARNING: To guard against injury, basic safety precautions should be observed,
including the following:

1. 

READ AND FOLLOW ALL SAFETY INSTRUCTIONS

 

 

Follow all important notices on the appliance before using the pump.

 

Failure to do so may result in loss of fish life and/or damage to this appliance.

2. 

DANGER

 – To avoid possible electric shock, special care should be taken since water is employed in the  

 

use of pond equipment. If pump is damaged in any way, do not attempt repairs yourself; return the

 

appliance to the store where it was purchased if still under warranty.

 

A 10mA or 30mA Residual Current Device (RCD) (or GFCI- Ground Fault Current  

 

 

Interrupter) MUST be fitted to the mains (main power supply) of the pump only.

A.  If the appliance shows any sign of abnormal water leakage or if RCD (or GFCI- Ground Fault Current    
 

Interrupter) switches off, disconnect the power supply cord from mains (main power supply) and remove  

 

pump from water.

B.  Carefully examine the appliance after installation. It should not be plugged if there is water on parts not  
 

intended to be wet.

C.  Do not operate any appliance if it has a damaged cord or plug, or if it is malfunctioning or if it is dropped  
 

or damaged in any manner. The power cord of this appliance cannot be replaced; if the cord is damaged,  

 

the appliance should be discarded. Never cut the cord.

 
3.  This appliance is not intended for use by persons (including children) with reduced physical, sensory or 
 

mental capabilities, or lack of experience and knowledge, unless they have been given supervision or    

 

instruction concerning use of the appliance by a person responsible for their safety.

4.  The pump is equipped with a thermal overload safety device. In the event of any overheating of the motor,  
 

this device automatically switches off the pump. The cooling time is roughly 15 to 20 minutes, and then  

 

the pump automatically comes on again. If the overload cutout is tripped, it is essential to identify and  

 

deal with the cause of the overheating.

5.  To avoid injury, do not touch moving parts or hot parts.
6. 

CAUTION

 – Always unplug or disconnect all appliances in the pond from the electrical supply before  

 

placing hands in water, before putting on or taking off parts and while the equipment is being installed,  

 

maintained or handled. When inserting or removing the pump from the water, always pull out the main  

 

electrical plug. Never yank the cord to pull the plug from outlet. Grasp the plug and pull to disconnect.  

 

Always unplug an appliance from an outlet when not in use. Never lift the pump by the cord or floating  

 

switch. Use the unit handle.

7. 

CAUTION

 – This is a Pond Pump. The pumps are designed to pump clean water or water containing solids  

 

with a diameter of up ¼, depending on model. 

This Pump Has Been Evaluated For Use With Freshwater Only.

  

 

Do not use this pump for other than its intended use (i.e.: do not use in swimming pools, bathrooms, etc.).  

 

The use of attachments not recommended or sold by the appliance manufacturer may cause an unsafe  

 condition.

Jolie 

Products, 

Inc

Summary of Contents for MaxDrive PT201

Page 1: ...assins de jardin et ornements aquatiques Bomba sumergible para estanques y decoraciones acu ticas Beautifully simple water gardening Am nager un bassin de jardin merveilleusement simple Perfecto para...

Page 2: ...J o l i e P r o d u c t s I n c...

Page 3: ...lations Ejemplos de diferentes instalaciones Designed to work in both vertical and horizontal applications Con ue pour fonctionner la verticale ou l horizontale Dise ada para funcionar en aplicaciones...

Page 4: ...the cord 3 This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given sup...

Page 5: ...ile the pump is in operation It is absolutely essential to prevent any risk of the pump freezing In the event of freezing temperatures remove the pump from the liquid empty it and keep it in a place w...

Page 6: ...d the more work you are asking your pump to do and therefore the more powerful it has to be It s a good idea to choose one with a capacity slightly greater than your initial needs especially since you...

Page 7: ...h Check that fluids being pumped are not too dense causing pump to overheat Ensure water temperature does not exceed 95 F 35 C Check strainer and impellor for obstructions CLEANING INTAKE STRAINER IMP...

Page 8: ...de cet appareil ne peut pas tre remplac si le cordon est endommag il faut jeter l appareil Ne jamais couper le cordon 3 Cet appareil ne doit pas tre utilis par des personnes y compris des enfants aux...

Page 9: ...l NEC exige qu un disjoncteur de fuite de terre GFCI soit install sur le circuit de d rivation alimentant toute pompe de puisard d eaux d gout d effluents de fontaine de piscine et d autres appareils...

Page 10: ...ent attendu de l appareil Servira t il seulement la circulation de l eau ou fera t il circuler l eau dans un filtre pour cascade un st rilisateur clarificateur UV une cascade ou un ornement aquatique...

Page 11: ...l eau qui entre dans la pompe est trop dense et pourrait causer la surchauffe de l appareil S assurer que la temp rature de l eau ne d passe pas 35 C 95 F V rifier si la cr pine d admission et l impul...

Page 12: ...sensoriales o mentales reducidas o personas sin experiencia ni conocimiento a menos que sean supervisadas o hayan recibido instrucciones sobre el uso del aparato de parte de una persona responsable d...

Page 13: ...riesgo de que la bomba se congele En caso de haber temperaturas bajo cero extraiga la bomba del l quido vac ela y mant ngala en un lugar donde no pueda congelarse Se recomienda asegurarse peri dicamen...

Page 14: ...trabajo le demandar a la bomba por lo tanto deber ser m s potente Es una buena idea elegir una bomba con una capacidad apenas mayor de lo que pretende al comienzo especialmente si desea agregar acceso...

Page 15: ...mo para causar el sobrecalentamiento de la bomba Procure que la temperatura del agua no supere los 35 C 95 F Verifique que el filtro o el impulsor no presenten obstrucciones LIMPIEZA DEL IMPULSOR FILT...

Page 16: ...3 4 A 7 6 A 10 A 11 2 A Puissance 260 W 370 W 820 W 1 000 W 1 100 W Nombre de chevaux vapeur 0 25 0 3 0 5 0 75 1 Longueur du cordon d alimentation 6 m 6 m 6 m 6 m 6 m Diam tre de sortie d eau 32 mm 32...

Page 17: ...a tarjeta de registro Si lo prefiere puede registrarse a trav s de nuestro sitio web www hagen com Mr Sr Mrs Sra Miss Srta Ms First Name Nombre Last Name Apellido PLEASE PRINT LETRA DE IMPRENTA DD MM...

Page 18: ..._______________________________ _________________________________________________________________________________________________ ______________________________________________________________________...

Page 19: ..._______________________________ _________________________________________________________________________________________________ ______________________________________________________________________...

Page 20: ...a Rolf C Hagen Inc Montreal QC H9X 0A2 U S A Rolf C Hagen U S A Corp Mansfield MA 02048 Printed in Italy Laguna and Hagen are registered trademarks of Rolf C Hagen Inc www lagunaponds com J o l i e P...

Reviews: