The Patient Kelly is a lifelike manikin, which realistically 
simulates a patient. It is specifically designed for training 
professionals in the practice of basic and advanced nursing 
techniques.  
 
The manufacturing quality of this simulator should provide 
many sessions of training when reasonable care and 
maintenance are practiced. 
 

 
 

Laerdal Recommends:

 

 

Tracheostomy tube – Size 6 

 

Syringe – 10 ml 
 
Urethral catheterization – Size 16 French 
catheter 
 
Manikin Lubricant or liquid soap 
 
 

 

 

 
 

301-00001 

                                          Laerdal 

 

 

 

4

Summary of Contents for Patient Kelly

Page 1: ...Patient Kelly Directions for Use...

Page 2: ...301 00001 Laerdal 2...

Page 3: ...ad 6 Tracheostomy Plug Care 6 NG Tube Placement 6 Stomach Reservoir 6 Chest Plate 6 Belly Plate 6 Injection Pads 7 Joints 7 Arms Legs 7 Colon Reservoir 8 Genitalia 9 Urinary Catheterization Enema Simu...

Page 4: ...actice of basic and advanced nursing techniques The manufacturing quality of this simulator should provide many sessions of training when reasonable care and maintenance are practiced Laerdal Recommen...

Page 5: ...t Spray 1 Tool Kit 1 Laerdal Global Warranty Booklet 1 Directions for Use Skills Taught Ostomy irrigation Catheterization Colonic irrigation Enema simulation Ear irrigation Subclavian Hickman Jejunost...

Page 6: ...nt This manikin features an esophagus and stomach reservoir for the practice of NG tube insertion and skills such as Gavage and Lavage Lubricate tube with either silicone spray or liquid detergent pri...

Page 7: ...procedure Waist Elbow Knee and Ankle Joints These joints are connected by a bolt and lock nut To remove unscrew lock nut Laerdal Recommends When assembled talcum powder should be used in joints to as...

Page 8: ...Insert bolt through hole in pelvis 4 Slide washer and wing nut back over bolt 5 Use a screwdriver to drive bolt into the wing nut Figure 2 Fig 2 To remove legs reverse procedure Colon Reservoir Colon...

Page 9: ...t be removed and replaced immediately when assembling and disassembling genitalia Figure3 To assemble 1 Screw both valves onto genitalia When attaching valves be sure alignment of genitalia urinary re...

Page 10: ...lubricant or full strength liquid soap prior to using If catheter hangs during removal work it with an in and out motion Use warm water in reservoirs when possible to keep soap from clogging the cathe...

Page 11: ...air dried thoroughly before storage and disinfected when needed After use of injection pads use water only accumulated water should be squeezed out Do not store wet foam pads in the skin To prevent mi...

Page 12: ...Adult Male 300 00450 Valve Clamp Set Anal Hosp Adult 300 00550 Valve Clamp Set Urinary Hosp Adult 300 00650 Lubricant Manikin 4 oz Bottle W Sprayer 300 00850 Plug Tracheostomy 300 01350 Reservoir Ass...

Page 13: ...e Set Adult Manikin Legs Arms to Body 300 04350 Hardware Set Adult Manikin Pelvis Torso 300 04850 Gown Hospital Back Tie 300 04950 Stoma Soft Style W Thru Hole 300 05150 Arm Assembly Left Plain Adult...