background image

300-03350 

 

Leg, Lower Left Adult 

300-03450 

 

Foot, Left Adult 

300-03850 

 

Genitalia Assembly, Adult Male 

300-03950 

 

Genitalia Assembly, Adult  

  

Female 

300-04050 

 

Pad Assembly, Right Forearm 

  

IV 

 

300-04150 

 

Pad Assembly, Left Forearm IV  

300-04250 

 

Hardware Set, Adult Manikin-

 

 

Legs/Arms to Body 

300-04350 

 

Hardware Set, Adult Manikin-

  

Pelvis/Torso 

300-04850 

 

Gown, Hospital-Back Tie 

300-04950 

 

Stoma, Soft Style W/Thru  

  

Hole 

300-05150                       

Arm Assembly, Left Plain  

 

 

 

 

Adult 

 

300-10250 

 

Chest plate, Hospital Plain  

  

Adult 

Male 

301-00150 

 

     

Head Assembly, Hard  

 

 

 

w/Trach Opening Adult Male 

 

 

 

 

 

Please contact Customer Service Representatives for more 
information on Replacement Parts in other skin tones.    

301-00001 

                                          Laerdal 

 

 

 

13

Summary of Contents for Patient Kelly

Page 1: ...Patient Kelly Directions for Use...

Page 2: ...301 00001 Laerdal 2...

Page 3: ...ad 6 Tracheostomy Plug Care 6 NG Tube Placement 6 Stomach Reservoir 6 Chest Plate 6 Belly Plate 6 Injection Pads 7 Joints 7 Arms Legs 7 Colon Reservoir 8 Genitalia 9 Urinary Catheterization Enema Simu...

Page 4: ...actice of basic and advanced nursing techniques The manufacturing quality of this simulator should provide many sessions of training when reasonable care and maintenance are practiced Laerdal Recommen...

Page 5: ...t Spray 1 Tool Kit 1 Laerdal Global Warranty Booklet 1 Directions for Use Skills Taught Ostomy irrigation Catheterization Colonic irrigation Enema simulation Ear irrigation Subclavian Hickman Jejunost...

Page 6: ...nt This manikin features an esophagus and stomach reservoir for the practice of NG tube insertion and skills such as Gavage and Lavage Lubricate tube with either silicone spray or liquid detergent pri...

Page 7: ...procedure Waist Elbow Knee and Ankle Joints These joints are connected by a bolt and lock nut To remove unscrew lock nut Laerdal Recommends When assembled talcum powder should be used in joints to as...

Page 8: ...Insert bolt through hole in pelvis 4 Slide washer and wing nut back over bolt 5 Use a screwdriver to drive bolt into the wing nut Figure 2 Fig 2 To remove legs reverse procedure Colon Reservoir Colon...

Page 9: ...t be removed and replaced immediately when assembling and disassembling genitalia Figure3 To assemble 1 Screw both valves onto genitalia When attaching valves be sure alignment of genitalia urinary re...

Page 10: ...lubricant or full strength liquid soap prior to using If catheter hangs during removal work it with an in and out motion Use warm water in reservoirs when possible to keep soap from clogging the cathe...

Page 11: ...air dried thoroughly before storage and disinfected when needed After use of injection pads use water only accumulated water should be squeezed out Do not store wet foam pads in the skin To prevent mi...

Page 12: ...Adult Male 300 00450 Valve Clamp Set Anal Hosp Adult 300 00550 Valve Clamp Set Urinary Hosp Adult 300 00650 Lubricant Manikin 4 oz Bottle W Sprayer 300 00850 Plug Tracheostomy 300 01350 Reservoir Ass...

Page 13: ...e Set Adult Manikin Legs Arms to Body 300 04350 Hardware Set Adult Manikin Pelvis Torso 300 04850 Gown Hospital Back Tie 300 04950 Stoma Soft Style W Thru Hole 300 05150 Arm Assembly Left Plain Adult...

Page 14: ...Laerdal Medical Gatesville TX All rights reserved 1005394 rev B August 30 2006 301 00001 Laerdal 14...