8. Accessories and Parts

Cat. No.

Description

78 00 00

LSU w/Reusable Canister

78 00 10

LSU w/Abbott Receptal® Canister

Consumables

78 12 00

Aerosol Filter for LSU Reusable Canister

78 12 01

Vacuum Tube for LSU Abbott Canister

78 12 02

High Effiency Filtration kit 

for LSU Abbott Canister

77 04 61

Abbott Disposable Liner

Accessories

78 20 00

Carrying Bag (full covering)

78 20 10

Semirigid carrying bag

78 26 00

Wall Bracket w/DC-Power Cord

78 26 10

Wall Bracket w/AC-Power Cord US

78 26 20

Wall Bracket w/AC-Power Cord EU

78 26 30

Wall Bracket w/AC-Power Cord UK

78 26 40

Wall Bracket wo/ Power Cord

78 23 00

Shoulder Strap

78 24 00

Side Pouch

78 04 40

External Charger kit

Parts

78 03 00

Directions for Use

77 04 10

Suction Tubing 150 cm w/o tip

65 01 13

Suction Catheter adapter, pkg. 10

78 40 00

LSU Reusable Canister

78 04 30

LSU Reusable Canister Holder

78 10 06

Angled Connectors, pkg. 10

78 10 02

Float Ball, pkg. 10

78 40 07

Vacuum Seal

78 40 08

Gasket

79 35 00

Water Container

77 04 62

Abbott Receptal Canister

78 04 10

Abbott Canister Holder

78 04 14

T-bar for Abbott 

Receptal Canister pkg. 5

78 04 33

Strap for Tubing

78 04 32

Release Arm

78 02 00

DC-Power Cord

78 02 10

AC-Power Cord US

78 02 20

AC-Power Cord EU

78 02 30

AC-Power Cord UK

78 04 00

LSU Battery

78 04 36

Fasten bracket left/right

78 04 35

Holder for water bottle

21

ENGLISH

Note: Parts or product configurations are subject to change without notice.

65 01 13

77 04 10

79 35 00

78 10 06

78 40 00

78 40 07

78 40 08

78 10 02

77 04 62

78 04 14

78 12 00

78 04 32

78 02 10
78 02 20
78 02 30

78 02 00

78 04 00

78 24 00

78 04 33

78 20 10

78 04 40

78 04 10
78 04 30

78 12 01

78 12 02

78 04 36

78 04 61

78 04 12

78 04 35

78 26 10
78 26 20
78 26 30
78 26 40

78 20 00

78 23 00

Summary of Contents for 78 00 00

Page 1: ...Directions for Use Laerdal Suction Unit www laerdal com 78 00 10 78 00 00...

Page 2: ...le to place the LSU on continuous charge when not in use make sure the battery is charged for a minimum of 24 hours at least once a month Do not store the battery when it is discharged always fully ch...

Page 3: ...lace the Disposable Canister 13 5 3 Assembly of the Disposable Canister System 14 5 4 After Use 15 6 Maintenance 15 6 1 General 15 6 2 Battery 15 6 3 Cleaning the Cabinet 15 6 4 Decontamination of Reu...

Page 4: ...m levels are usually selected for tracheal suctioning and the suctioning of children and infants 2 3 Contraindications None known 2 4 Features and Benefits Splashproof rugged and solid Easy access to...

Page 5: ...nt Suction Tubing Suction Catheter Adapter Holder for Water Bottle Patient Suction Tubing Water Bottle Canister Lid with Float Ball Battery Door Release Arm Canister 3 1 2 LSU w Disposable Canister Sy...

Page 6: ...it continuously while the LSU is switched ON It flashes rapidly approx twice per second during the Device Test It flashes slowly approx once per second while the Automatic Power save Function is activ...

Page 7: ...ately after switching from external power to internal battery operation all 4 LED s will flash for 5 seconds before the remaining battery capacity is displayed CAPACITY for a new battery stored in roo...

Page 8: ...d without the Aerosol Filter or the Float Ball It is recommended always to have extra Aerosol Filters with the LSU in case one has to be discarded The Aersol Filter is not intended for microbio logica...

Page 9: ...ng external Power Sources AC mains when used with the AC Power Cord 100 240 VAC 50 60 400 Hz DC mains when used with the DC Power Cord 12 28 VDC A Wall Bracket to hold the LSU during operation and opt...

Page 10: ...ting Knob to the required vacuum level The LSU will automatically be switched ON and start to operate The green Power ON Indicator is lit continuously while the LSU is switched ON 6 When suction is co...

Page 11: ...yellow Gasket in the Lid make sure that the gasket is placed flat in the Lid and not twisted 2 If the Float Ball has been removed hold the lid upside down and snap the ball into place as shown Note Ne...

Page 12: ...olor code Blue on Blue Yellow onYellow 4 3 1 Reusable Canister System Quick reference The assembly of the tubing is illustrated on the right side of the LSU 1 Connect the blue Aerosol filter to the bl...

Page 13: ...erated in the upright position to prevent overflow of suctioned material 7 Set the Operating Knob to the required vacuum level and the LSU will automatically be switched ON and start to operate The gr...

Page 14: ...to the blue Vacuum Inlet on the LSU Color Code Blue on Blue 4 Insert the Canister in the in the Canister Holder and slide it into the LSU 5 Connect the yellow Connector on the Vacuum tubing to the Ye...

Page 15: ...ed both on a monthly basis and after each use 6 2 Battery To maintain satisfactory operation of the battery it is recommended to place the LSU on continuous charge when not in use Replace the battery...

Page 16: ...eparate parts as indicated in the picture above The Float Ball on the reusable canister can be snapped out of the lid 6 4 3 Rinsing Rinse all parts under cold running water Immerse in warm water 30 40...

Page 17: ...24 hours at least once a month Do not store the battery when it is discharged Always fully charge the battery before storage The recommended ambient temperature for charging is from 15 C to 25 C The...

Page 18: ...is user initiated test program for all models which can identify whether the LSU operates satisfactorily or if the LSU needs service The program runs 4 different tests 1 It tests for occlusions in th...

Page 19: ...est results turn the Operating Knob to 0 to exit the Device Test Note If you need to interrupt the test and revert to nor mal operation turn the Operating Knob to another position and then select the...

Page 20: ...LED 2 lit up LED 3 lit up LED 4 lit up Test result indications Test Passed 100 mmHg Test Passed 300 mmHg Test Passed 500 mmHg Test Passed 450 mmHg Action if test failed Check possible blockages e g tw...

Page 21: ...ter adapter pkg 10 78 40 00 LSU Reusable Canister 78 04 30 LSU Reusable Canister Holder 78 10 06 Angled Connectors pkg 10 78 10 02 Float Ball pkg 10 78 40 07 Vacuum Seal 78 40 08 Gasket 79 35 00 Water...

Page 22: ...n the Abbott canister is leaking air into the tubes The Abbott liner is leaking Battery is not charged Tube s is kinked or twisted The external Power indicator is not lit ACTION Check power cord conne...

Page 23: ...e Overall tolerance 5 11 3 Physical Characteristics Size 315 mm 12 4 in x 330 mm 13 in x 160 mm 6 3 in h x w x d Weight 4kg 8 9 lbs including battery Canister Capacity 1000 ml Canister graduation accu...

Page 24: ...front Styrene Ethylene Betyl Styrene SEBS Cabinet back PC ABS Cabinet base w Protector PC ABS SEBS Battery door SEBS Connector retainer for battery Poly Oxy Methylene POM Operating Knob POM Rotor for...

Page 25: ...rovided in this section Portable and mobile RF communication equipment can affect MEDICAL ELECTRICAL EQUIPMENT Warning MEDICAL ELECTRICAL EQUIPMENT should not be used adjacent to or stacked with other...

Page 26: ...30 dip in UT for 25 cycles 5 UT 95 dip in UT for 5 sec 5 UT 95 dip in UT for 0 5 cycle 40 UT 60 dip in UT for 5 cycles 70 UT 30 dip in UT for 25 cycles 5 UT 95 dip in UT for 5 sec Mains power quality...

Page 27: ...cy rangeb Interference may occur in the vicinity of equipment marked with the following symbol Guidance and manufacturer s declaration electromagnetic immunity NOTE 1 At 80 MHz and 800 MHz the higher...

Page 28: ...2005 Laerdal Medical AS All rights reserved 8179 Rev A Printed in Norway 0434...

Reviews: