background image

 

 

The configuration mode is activated by pressing touch screen field 29, “ALARM VALUES”, for 3 
seconds. The following diagram shows an example of a display with the configuration mode 
activated. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
You can exit the configuration mode by pressing the “END” key. 
 

Illumination time for AC adaptor operation 

The illumination time for AC adaptor operation (“line”) is displayed in the “LIGHT” field (touch 
screen field 1). 

A setting here is only meaningful when the weather station is powered by 

means of the AC adaptor power supply. 

The time displayed shows in hours and minutes how long the display is to remain lit after the last 
touch screen field has been pressed. 
A value of 0:00 means that the illumination will never come on. 
A value of -:-- (appears after 9:59) means that the illumination will stay on continuously until it is 
turned off manually (“LIGHT OFF” in the main display). 

Touch screen field 1 must be pressed in order to set the required ON time. 

The associated display will now flash: 

 
 
 
 
 
 
 
 
 

 

The required value between 0:00 and 9:59 as well as “-:--” can now be set using the touch 
screen fields “+” and “–”. It is possible to run through the display more quickly by pressing 
the relevant touch screen field for longer. 

When the required value has been set, you can exit set-up by pressing the “END” key. The 
value is now stored. 

 
 
 

Illumination time for battery operation 

The illumination time for battery operation (“batt”) is displayed in the “LIGHT” field (touch screen 
field 2). A setting here is only meaningful when the weather station is powered 

exclusively 

by 

batteries. 
The time displayed shows in seconds (up to 99) how long the display is to remain lit after the last 
touch screen field has been pressed. 
A value of 0 means that the illumination will never come on. 

Touch screen field 2 must be pressed in order to set the required ON time. 

The associated display will now flash: 

 
 
 
 
 
 
 
 
 

 

The required value between 0 and 99 seconds can now be set using the touch screen fields 
“+” and “–”. It is possible to run through the display more quickly by pressing for longer. 

When the required value has been set, you can exit set-up by pressing the “END” key. The 
value is now stored. 

 

Setting the temperature display units 

The display units for temperature are shown in touch screen field 4 at the top right. 
The factory setting is ºF. 

By touching field 4 the display units can be switched between ºF and ºC. 

 

Calibration of the rainfall reading indicator 

The rainfall measuring system is delivered with a very high accuracy, so that normally no 
calibration is required. 
A calibration only becomes necessary when very high accuracy is required for 
professional use or for special purposes. 

Before starting the calibration of the rainfall reading indicator, set any existing summed rainfall 
value in the normal display mode back to zero (see section “Rainfall measurement“). 
 
For the exact calibration proceed as follows: 
1. 

Allow 6.1 cu. in. of water to trickle continuously and distributed evenly into the funnel over a 
period of 10 minutes. In doing so, there must be a period of at least 15 seconds between the 
individual rocker movements. If the rocker tilts more quickly, the amount of water flowing 
through is too great and the flow must be reduced. 

2. 

After the water has completely run through, it is necessary to wait for a further period of 6 
minutes. The total amount indicated should now be 0.3 in.  

3. 

If a different value is displayed, then the rocker value should be recalculated as follows: 

 
New rocker value = 

0.3 x current rocker value 

Actual value (display when filled with water) 
 

The calibration value of the rainfall per rocker stroke for the rain sensor is shown in touch screen 
field 8 (top center). It is always given in ml/rocker stroke, 

the units on the right are the units for 

the subsequent display of rainfall! 

and the lower touch screen field will change to the following form:

 

and the lower touch screen field will change to the following form:

 

Summary of Contents for WS-2510

Page 1: ...emarkable It does not use any operating elements but is operated solely via a large touch sensitive LC display The display can be illuminated permanently or on a time basis so that it can be easily read under nearly all light conditions The weather station can optionally be powered by means of batteries or with the plug in power adaptor provided particularly recommended when the display is continu...

Page 2: ...or 2 1 Current humidity of the selected outdoor sensor 3 Trend display for the temperature at the location of the respective sensor 4 Comfort zone indicator for the display of pleasant unpleasant climate 5 Display of the wind speed 6 Display of the current wind direction 7 Variation range display for variable winds 8 Display of rainfall umbrella means it is currently raining 9 Display of the curre...

Page 3: ...e of the desk stand for when the unit is mounted on the desk When using this method any cables that are connected should be laid tidily in the slots of the desk stand in order to ensure an inconspicuous and orderly routing of the cables Commissioning After the batteries have been inserted or the unit has been connected to the power supply a short test of all the display segments is carried out all...

Page 4: ...sors In the WS 2510 25 and WS 2510 19 outdoor sensors the magnet for activating the system is pressed into an opening provided for it in the rear of the housing The wind sensor WS 2510 15 is also activated by inserting a small magnet into the opening provided The magnet holder is located above the holding pipe fixing opposite the solar cell To insert the magnet in the WS 2510 16 rain sensor press ...

Page 5: ...ew on page 4 The addressing can be set individually according to section 2 3 4 Since it is exclusively battery operated this sensor is suitable for use in dark inner rooms such as a garage a wine cellar or loft 2 3 6 WS 2510 27 temperature humidity sensor The WS 2510 27 requires two AA alkaline batteries for operation It enables the recording of garden pond or ground temperatures or similar by mea...

Page 6: ...lumination will now remain switched on for the programmed time after the last key press As standard the illumination is active for 10s with battery operation and continuously on when using the AC power adaptor To switch off the illumination manually press the LIGHT OFF key bottom left field 23 The times for the illumination can be set up in configuration mode Cleaning mode As the display becomes d...

Page 7: ...he required value between 0 and 99 seconds can now be set using the touch screen fields and It is possible to run through the display more quickly by pressing for longer When the required value has been set you can exit set up by pressing the END key The value is now stored Setting the temperature display units The display units for temperature are shown in touch screen field 4 at the top right Th...

Page 8: ...tched between inHg hPa or mmHg Keypad beep on off The keypad beep can be switched on Sound on or off Sound off by touching field 12 Setting the display type for the history trend display By touching field 16 the history display can be switched between a bar and a line display Bar display Line display Setting the sunshine threshold value The set up field enables the brightness threshold to be set a...

Page 9: ...viating from address 7 If an address is changed here after leaving the configuration mode the weather station will carry out a complete sensor synchronization for 6 minutes as at 7 30am Sensor protocol version 4 1 Sensor addresses The sensor addresses can be set up by touching the associated field 0 to 7 2 Protocol version The sensor protocol version can be changed over between 1 1 and 1 2 by touc...

Page 10: ...en fields see page 11 Touch screen field 3 switches over between the display of temperature perceived temperature and dew point Touch screen field 4 selects the next sensor if available 1 8 Touch screen field 5 selects the previous sensor if available 8 1 3 2 2 Wind measurement field 7 The display field for the wind measurement is situated in the middle on the left Here the main wind direction the...

Page 11: ... between displaying the absolute and the relative air pressure using touch screen fields 10 and 11 Please note A difference between the absolute and relative air pressure will only be displayed when the height corrected value for the relative air pressure has previously been entered 3 2 5 Weather forecast Based on years of experience in the development of weather measurement technology the weather...

Page 12: ...display field for the current brightness BRIGHTNESS is situated at the bottom right of the display 1 The current brightness is displayed in lux or klux as appropriate 2 Here the Graph symbol shows that the trend display for the brightness has been selected in the history field It only appears if it has previously been selected No key functions 3 2 9 Time Date The display field for the time date is...

Page 13: ...ually by pressing the END key the min max display will be terminated automatically 2 minutes after the last key has been pressed and the unit will revert to normal display mode Only the maximum value display is available for the rain and wind sensor In the case of the rain sensor the display modes for the maximum value display are adapted as follows Total maximum value that occurred in the last 24...

Page 14: ...r pressure 700 hPa to 1099 hPa 525 mmHg to 824 mmHg 20 65 inHg to 32 42 inHg 3 4 3 Setting the wake up times Please note The wake up time including the associated day can only be edited in the MAX alarm value display The day for which the wake up function is to be set can be set using the DAY field field 27 The display means that the wake up time set applies to all 7 days of the week daily wake up...

Page 15: ...nsmitted readings are No reception The distance between transmitter and receiver is too great Reduce the distance between the transmitter and the receiver No reception dense shielding materials are positioned between the transmitter and the receiver thick walls reinforced concrete Find another position for the transmitter and receiver See also section 6 Range Transmitter batteries are discharged C...

Page 16: ...C size alkaline batteries Plug in power supply 7 5 V 500 mA Dimensions W x H x D Housing 10 1 x 8 3 x 1 4 257 x 211 x 36 mm 10 Explanation of terms Perceived temperature see Wind chill Dewpoint Temperature point that is dependent on the conjunction of a specific air pressure a specific temperature and a specific humidity At this temperature the humidity in the air begins to condense the so called ...

Page 17: ...t a temperature of 77 F 25ºC for example to be too dry e g heating air and one above 60 to be oppressive 11 Warranty Information La Crosse Technology provides a 1 year warranty on this weather station Contact La Crosse Technology immediately upon discovery of any defects covered by this warranty Before sending the weather station in for repairs contact La Crosse Technology The weather station will...

Page 18: ...g errors or their consequences All trademarks and patents are acknowledged THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS 1 THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE AND 2 THIS DEVICE MUST ACCEPT INTERFERENCE RECEIVED INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION Touch Screen Wireless Weather Station WS 2510 Operating instru...

Reviews: