background image

 

 

Example for the display of maximum values 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Example for the display of minimum values.

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Display min/max values 

The display mode is selected by touching the appropriate field “MAX” (field 27) or “MIN” 
(field 25). The particular touch screen field activated (MIN or MAX) will be faded out. Both 
titles are only visible in normal display mode. 

If the touch screen field for a value is then pressed, the time of the occurrence associated 
with this value will be displayed in the time/date field (20/21) for 10s. 

If the touch screen field is pressed again while the time is being displayed, the display mode 
for the value concerned will be stepped forwards. 
Indoor sensor: Temperature -> Dewpoint -> 
Outdoor sensor: Temperature -> Dewpoint -> Perceived temperature -> 
The outdoor sensors are selected using touch screen fields 4 or 5 as with the normal 
display. 
Wind sensor: Wind speed: km/h ->m/s ->mph ->knots ->Beaufort -> 
Rain sensor: Amount per day/hour: 24 h ->1 h -> 

You can return to the normal display by pressing the “END” key. 

 
Deleting min/max values 

If the “RESET” field is pressed while the time of the minimum or maximum values is being 
displayed, the value concerned will be deleted. 

If the “RESET” field is pressed for 3 seconds, all the stored values will be deleted. 

 
History display for min/max values 

By using the SELECT function (touch screen field 16) and then selecting the required value, 
the minimum/maximum trends of the individual values can also be checked depending on 
the previous choice of the min/max function (see also the section “History”). 

 

Please note! 

If not exited manually by pressing the “END” key, the min/max display will be terminated 
automatically 2 minutes after the last key has been pressed and the unit will revert to normal 
display mode. 

Only the maximum value display is available for the rain and wind sensor. 

In the case of the rain sensor, the display modes for the maximum value display are adapted 
as follows: 
Total: ->maximum value that occurred in the last 24 hour 
Current 24h -> maximum value that occurred in the last 24h 
24h -> maximum value that occurred in the last 24 h 
Current hour -> maximum value that occurred in the last hour 
1h -> maximum value that occurred in the last hour 

In the case of the hours of sunshine, the “h/day” display mode is always set. 

In the case of the wind speed display, the wind direction associated with the maximum value 
that occurred will also be displayed concurrently. 

 

3.4. 

Programming mode (entering alarm values) 

You can program the weather station so that an audible-visible alarm occurs when certain 
minimum or maximum values are reached. As well as this, daily wake-up times can be 
programmed so that the weather station can also be used as an alarm clock or an appointment 
reminder. 
 

Alarm values can be set for: 

-

High or low temperature for all sensors 

- High or low humidity for all sensors with humidity 
- High and low air pressure 
- High wind speed 
- Daily wake-up time 
- Separate wake-up time for each day of the week 
 

3.4.1. 

Programming the min/max alarm values 

The programming mode is selected by touching field 29 (“ALARM VALUES”). 
The display shown below is an example of how the screen appears for the MAX alarm 
values and the daily wake-up time. If no alarm value has been set, dashes appear in place of 
the value display. 

Wake-up times are only shown in the MAX display. 

 
 
 
 
 
 

 

 

Summary of Contents for WS-2510

Page 1: ...emarkable It does not use any operating elements but is operated solely via a large touch sensitive LC display The display can be illuminated permanently or on a time basis so that it can be easily read under nearly all light conditions The weather station can optionally be powered by means of batteries or with the plug in power adaptor provided particularly recommended when the display is continu...

Page 2: ...or 2 1 Current humidity of the selected outdoor sensor 3 Trend display for the temperature at the location of the respective sensor 4 Comfort zone indicator for the display of pleasant unpleasant climate 5 Display of the wind speed 6 Display of the current wind direction 7 Variation range display for variable winds 8 Display of rainfall umbrella means it is currently raining 9 Display of the curre...

Page 3: ...e of the desk stand for when the unit is mounted on the desk When using this method any cables that are connected should be laid tidily in the slots of the desk stand in order to ensure an inconspicuous and orderly routing of the cables Commissioning After the batteries have been inserted or the unit has been connected to the power supply a short test of all the display segments is carried out all...

Page 4: ...sors In the WS 2510 25 and WS 2510 19 outdoor sensors the magnet for activating the system is pressed into an opening provided for it in the rear of the housing The wind sensor WS 2510 15 is also activated by inserting a small magnet into the opening provided The magnet holder is located above the holding pipe fixing opposite the solar cell To insert the magnet in the WS 2510 16 rain sensor press ...

Page 5: ...ew on page 4 The addressing can be set individually according to section 2 3 4 Since it is exclusively battery operated this sensor is suitable for use in dark inner rooms such as a garage a wine cellar or loft 2 3 6 WS 2510 27 temperature humidity sensor The WS 2510 27 requires two AA alkaline batteries for operation It enables the recording of garden pond or ground temperatures or similar by mea...

Page 6: ...lumination will now remain switched on for the programmed time after the last key press As standard the illumination is active for 10s with battery operation and continuously on when using the AC power adaptor To switch off the illumination manually press the LIGHT OFF key bottom left field 23 The times for the illumination can be set up in configuration mode Cleaning mode As the display becomes d...

Page 7: ...he required value between 0 and 99 seconds can now be set using the touch screen fields and It is possible to run through the display more quickly by pressing for longer When the required value has been set you can exit set up by pressing the END key The value is now stored Setting the temperature display units The display units for temperature are shown in touch screen field 4 at the top right Th...

Page 8: ...tched between inHg hPa or mmHg Keypad beep on off The keypad beep can be switched on Sound on or off Sound off by touching field 12 Setting the display type for the history trend display By touching field 16 the history display can be switched between a bar and a line display Bar display Line display Setting the sunshine threshold value The set up field enables the brightness threshold to be set a...

Page 9: ...viating from address 7 If an address is changed here after leaving the configuration mode the weather station will carry out a complete sensor synchronization for 6 minutes as at 7 30am Sensor protocol version 4 1 Sensor addresses The sensor addresses can be set up by touching the associated field 0 to 7 2 Protocol version The sensor protocol version can be changed over between 1 1 and 1 2 by touc...

Page 10: ...en fields see page 11 Touch screen field 3 switches over between the display of temperature perceived temperature and dew point Touch screen field 4 selects the next sensor if available 1 8 Touch screen field 5 selects the previous sensor if available 8 1 3 2 2 Wind measurement field 7 The display field for the wind measurement is situated in the middle on the left Here the main wind direction the...

Page 11: ... between displaying the absolute and the relative air pressure using touch screen fields 10 and 11 Please note A difference between the absolute and relative air pressure will only be displayed when the height corrected value for the relative air pressure has previously been entered 3 2 5 Weather forecast Based on years of experience in the development of weather measurement technology the weather...

Page 12: ...display field for the current brightness BRIGHTNESS is situated at the bottom right of the display 1 The current brightness is displayed in lux or klux as appropriate 2 Here the Graph symbol shows that the trend display for the brightness has been selected in the history field It only appears if it has previously been selected No key functions 3 2 9 Time Date The display field for the time date is...

Page 13: ...ually by pressing the END key the min max display will be terminated automatically 2 minutes after the last key has been pressed and the unit will revert to normal display mode Only the maximum value display is available for the rain and wind sensor In the case of the rain sensor the display modes for the maximum value display are adapted as follows Total maximum value that occurred in the last 24...

Page 14: ...r pressure 700 hPa to 1099 hPa 525 mmHg to 824 mmHg 20 65 inHg to 32 42 inHg 3 4 3 Setting the wake up times Please note The wake up time including the associated day can only be edited in the MAX alarm value display The day for which the wake up function is to be set can be set using the DAY field field 27 The display means that the wake up time set applies to all 7 days of the week daily wake up...

Page 15: ...nsmitted readings are No reception The distance between transmitter and receiver is too great Reduce the distance between the transmitter and the receiver No reception dense shielding materials are positioned between the transmitter and the receiver thick walls reinforced concrete Find another position for the transmitter and receiver See also section 6 Range Transmitter batteries are discharged C...

Page 16: ...C size alkaline batteries Plug in power supply 7 5 V 500 mA Dimensions W x H x D Housing 10 1 x 8 3 x 1 4 257 x 211 x 36 mm 10 Explanation of terms Perceived temperature see Wind chill Dewpoint Temperature point that is dependent on the conjunction of a specific air pressure a specific temperature and a specific humidity At this temperature the humidity in the air begins to condense the so called ...

Page 17: ...t a temperature of 77 F 25ºC for example to be too dry e g heating air and one above 60 to be oppressive 11 Warranty Information La Crosse Technology provides a 1 year warranty on this weather station Contact La Crosse Technology immediately upon discovery of any defects covered by this warranty Before sending the weather station in for repairs contact La Crosse Technology The weather station will...

Page 18: ...g errors or their consequences All trademarks and patents are acknowledged THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS 1 THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE AND 2 THIS DEVICE MUST ACCEPT INTERFERENCE RECEIVED INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION Touch Screen Wireless Weather Station WS 2510 Operating instru...

Reviews: