5. Using Your LaCie Biggest F800
page 40
LaCie Biggest F800
User’s Manual
5.2.3.4. RAID Configuration Error Message
5.2.3.5. Overheating Error Message
RAID Level
Unmatched
RAID Fail
code: 1 <---->
The setting of the RAID Level
Switch Selectors does not match
the exisiting RAID level.
• The LaCie Biggest F800 is shut
down and the RAID Level Switch
Selectors are re-set to their original
RAID level
The setting of the RAID Level
Switch Selectors does not match
the exisiting RAID level.
• If you intend to initialize a new
RAID array, re-insert four disks and
create a new RAID; or
• The LaCie Biggest F800 is shut
down and the RAID Level Switch
Selectors are re-set to their original
RAID level
LCD Display
Message
Message cleared when...
Temperature!!
Ambient Temperature°C > 35°C
Over Temperature
Disk Shutdown!
The temperature of the LaCie
Biggest F800 has reached 53°C.
• The temperature drops below 53°C
The temperature of the LaCie
Biggest F800 has exceeded 55°C.
• All of the disks are shutdown and
the FAN module has been replaced
LCD Display
Message
Message cleared when...