5.5. RAID 6
In RAID 6, data is striped across all disks (minimum of four) and a
two parity blocks for each data block (p and q in
Fig. 87
) is written
on the same stripe. If one physical disk fails, the data from the failed
disk can be rebuilt onto a replacement disk. This Raid mode can
support up to two disk failures with no data loss. RAID 6 provides
for faster rebuilding of data from a failed disk.
Applications
RAID 6 provides data reliability with the addition of efficient rebuild-
ing in the case of a failed drive. RAID 6 is therefore useful for people
who need serious security with less of an emphasis on performance.
How RAID 6 Capacity Is Calculated
Each disk in a RAID 6 system should have the same capacity.
Storage capacity in a RAID 6 configuration is calculated by sub-
tracting the number of drives by two and multiplying by the disk
capacity, or
C = (n-2)*d
where:
C = available capacity
n = number of disks
d = disk capacity
For example, in a RAID 6 array with five drives each with a capac-
ity of 1000GB, the total capacity of the array would be 3000GB:
C = (5-2)*1000
RAID 6
Disk 1
Disk 2
Disk 3
Disk 4
Disk 5
Ap
Bq
C3
D3
Aq
B3
C3
D3
A3
Cq
D2
Bp
A2
B2
Dq
Cp
A1
B1
C1
Dp
Fig. 87