LaCie 12big Rack Network
Installation
User Manual
page 20
2.5. Chassis Installation
2.5.1. Parts Check List
✦
•Chassis, complete with Backplane PCB, ATX Motherboard,
Enclosure Management PCB, SAS Expander PCB, Ops Panel,
Intel® RAID Controller (optional), Battery Backup Unit (op-
tional), Blank Plates (covering empty PCI slots) and all plug-in
modules installed.
✦
Rack Mounting Rail Kit
2.5.2. Procedure
1. Check for damage.
2. Lift chassis and align with front rails.
3. Carefully insert chassis slides into rack rails and push fully home.
4. Tighten rear screws.
5. Withdraw chassis until it reaches hard stops (approximately
400mm).
6. Tighten front screws.
7. Return chassis to fully home position and attach to rack using
captive fasteners on front flanges.
IMPORTANT INFO:
Chassis rails have features to restrict chassis
withdrawal while allowing access to fans. If it becomes necessary to
remove the chassis completely, pull the chassis out until it reaches
its stops then rotate the latches shown in
Fig. 13
(right hand up, left
hand down) before continuing to fully withdraw the chassis.
2.6. Module Installation
IMPORTANT INFO:
LaCie 12big Rack Network enclosures are
supplied and delivered populated with Backplane PCB, ATX Mother-
board, Enclosure Management PCB, SAS Expander PCB, Ops Pan-
el, Intel® RAID Controller (optional), Battery Backup Unit (optional)
and all plug-in modules installed.
For information on removal/replacement of plug-in modules, please
refer to
4. Troubleshooting & Problem Solving
.
2.6.1. Dummy Drive Carrier Modules
Dummy Drive Carrier modules must be fitted in all unused drive bays
to maintain a balanced airflow.
2.6.2. Blanking Plates
Blanking Plates must be fitted in any vacant PSU bay or PCI card
slots at the rear of the enclosure to maintain airflow and ensure
correct operation.
IMPORTANT INFO:
Operation of the enclosure system with ANY
modules missing will disrupt the airflow and the drives will not re-
ceive sufficient cooling.
2.7. Power Cord Connection
2.7.1. Parts Check List
✦
Power cords to requisite local standards
2.7.2. Procedure
1. Attach the power cords to the two Power Supply Units.
IMPORTANT INFO:
To ensure redundancy the two power cords
must be connected to separate and independent supplies.
2. The Power On LED on each PSU indicates whether AC mains
power is present (flashing Green).
CAUTION:
The power connections must always be disconnected
prior to removal of the Power Supply Unit from the enclosure.
CAUTION:
Bifurcated power cords MUST NOT be used with the
LaCie 12big Rack Network enclosure, this system does not support