Page 7 of 8
CLUNY
INFORMATION
Back Spacer Vent Fitting
In order to meet UL requirements, it is MANDATORY to mount the back spacer vent
A
supplied with the appliance (or
equivalent) to the wall, this allows for ventilation and provides safety clearances to prevent heat damage.
Screw the 2 brackets
G
to the wall according to figures 14, 15 and 16 (screws not supplied), then fit the back spacer vent
onto these brackets by using the washers and nuts supplied with the range.
Shipping
Shipment / Packaging :
Unpack and check the appliance is in good condition. In case of damage, note any reservations on the delivery note and
confirm them within 48 hours by registered letter with confirmation of delivery to the carrier.
Appliance
Crate Width
Crate Depth
Crate Height
Crate & Range Weight
Range alone Weight
LG 1052
121 cm / 48’’
90 cm / 36’’
109 cm / 43’’
450 lb
350 lb
Figure 14
G
A