CLUNY
INFORMATION
Cabinet Preparation
The range is a free standing unit. If the unit is to be placed next to cabinets, the clearances shown in Figure 6 are
required.
The top grate support must be 34 mm - 1
5
/
8
’’ above the adjacent base cabinet countertop.
Min clearances to combustibles :
2 3/4’’ (70 mm) from rear of range to wall. This requirement will be met when range is installed with factory
supplied back spacer vent (or equivalent). It is critical to allow free circulation of air behind the appliance.
0’’ (0 mm) from sides below 36’’ (914 mm) height.
2’’ (51 mm) from sides above 36’’ (914 mm) height.
Use range only with factory supplied legs.
A B C D E F G H I J K L M N O
mm 762 330
457 914 150 230 175 395 20
60 765 865 1005 51 660
’’ 30 13 18 36
5
15
/
16
9
1
/
16
6
7
/
8
15
9
/
16
13
/
16
2
3
/
8
30
1
/
8
34
1
/
16
39
9
/
16
2 26
Fig. 6
B
A
D
K
G
I
C
J
E
F
H
L
M
N
N
Gas
pipe from
range in this area
Electrical connection access
panel of range in this area
O
NOTE: The above diagram depicts the actual location of gas and electrical connections on the range.
DO NOT place gas stub-out or electrical receptacle in these areas. Place them nearby in accordance with
local regulations.