background image

 

Page 1 of 8 

CLUNY 

INFORMATION

 

60 mm

3

/

’’

225 mm

7

/

’’ 

Fig. 3 

1065 mm 

41 

15

/

16 

’’ 

940 mm 

37’’

727.5 mm-28 

5

/

’’

800 mm-31 

1

/

’’ 

430 mm-16 

15

/

16 

’’

34 mm 

5

/

16 

’’

650 mm-25 

9

/

16 

’’

671 mm-26 

7

/

16 

’’

47 mm-1 

7

/

’’ 

510 mm-20 

1

/

16 

’’

147 mm

25

/

32 

’’ 

40 mm 

9

/

16 

’’

Back space vent 

(A) 

708 mm-27 

7

/

’’

Gas Connection

Electrical 
Connection

914 mm 

36’’ 

399 mm
15 

11

/

16

’’

768 mm

30 

1

/

4

 

1000 mm - 39 

3

/

’’ 

958 mm-37 

11

/

16 

’’ 

20 mm- 

13

/

16 

’’ 

Fig. 1 

Electrical Connection: 
120/240 VAC, 3 Pole, 4 Wire 
(See Table 2 for amperage) 

Gas Connection : 
Male coupling, 1/2" ID NPT 
73,500 BTU 
(5 Burners => 60,000 BTU) 
(Oven => 13,500 BTU) 

ATTENTION!! 

USING HANDLES/BARS TO LIFT 
WILL DAMAGE THE RANGE AND 
VOID THE WARRANTY! 

Fig. 2 

Fig. 4 

Summary of Contents for CLUNY LG1052G

Page 1: ...m 1 9 16 Back space vent A 708 mm 27 7 8 Gas Connection Electrical Connection 914 mm 36 399 mm 15 11 16 768 mm 30 1 4 1000 mm 39 3 8 958 mm 37 11 16 20 mm 13 16 Fig 1 Electrical Connection 120 240 VAC...

Page 2: ...Ovens Gas oven Enameled sheet metal Dimensions W x H x D 400 mm 15 3 4 x 305 mm 12 x 460 mm 18 1 8 Four shelf positions with 58 mm 2 1 4 spacing 55 liters 1 94 ft3 Heating is provided by a thermostat...

Page 3: ...on of air behind the appliance 0 0 mm from sides below 36 914 mm height 2 51 mm from sides above 36 914 mm height Use range only with factory supplied legs A B C D E F G H I J K L M N O mm 762 330 457...

Page 4: ...und Before connecting electrical power check that The supplied voltage is compatible with the appliance s rated voltage and thermal output Cluny Power Specification Chart Table 2 MODEL Voltage V Amper...

Page 5: ...und A 14 wire jumper may be added between the neutral and ground terminals on the terminal block Figure 10 Remove access door B Figure 7 two gas ovens or C Figure 8 gas and electric ovens Connect the...

Page 6: ...al codes Before connecting the gas Ensure that the pipework is perfectly clean in order to prevent the injectors from becoming blocked and magnetic heads malfunctioning Confirm the gas for which the a...

Page 7: ...14 15 and 16 screws not supplied then fit the back spacer vent onto these brackets by using the washers and nuts supplied with the range Shipping Shipment Packaging Unpack and check the appliance is...

Page 8: ...nd drawer push the range against the wall until the anti tip bracket screw goes through the back of the range Through the drawer gap screw the nut and its washer on the anti tip bracket screw G H A 48...

Reviews: