INSTALLER’S MANUAL
SERVICING / REPAIRS
To reset limiting thermostat
The button is behind the ventilation strip . To have access there, it is necessary to use a small
screwdriver to press on the push-button and reset limiting thermostat (see
A
, figure
1
).
CAUTION :
Do not obstruct the vents.
When installing ensure there is a 50 mm gap between the partition and appliance to enable the
induction plate to cool down correctly.
All work on or repair of an appliance must be carried out by a qualified engineer.
Before any work is carnied out on the appliance it must be disconnected from the main electricity
supply by disconnecting the terminal strip located on the back of the unit.
Limiting thermostat :
I
n accordance with the construction regulations, the limiting thermostat is intended to protect the
range from overheating.
I
n the event of overheating the limiting thermostat is triggered and cuts out the range’s oven
functions.
T
he advanced technology used in the limiter means that it is very sensitive to impacts and vibration
1
A
Citeaux induction - Ft 158a - GB - Rév 06 - Modifié le : 07/10/2013 13/36
Summary of Contents for CITEAUX INDUCTIONLVI 1532 E / CT
Page 6: ......
Page 8: ......
Page 16: ......
Page 22: ...Citeaux induction Ft 158a GB R v 06 Modifi le 07 10 2013 22 36...
Page 28: ......