background image

 

Café Moderne Range Hoods 

 

 

Installation, Operating & Maintenance Instructions 

 

 

W1512 FMOD Moderne Range Hood O&M Dec 16.docx 

Page 7 

Fornair

 

 

9. 

SEM REMOTE MOTOR WIRING ILLUSTRATIONS

 

 

 

 

 

Remote Motor 

Terminal Box 

Fig. 1 Open Terminal Box 

Empty Terminal for 
Motor Connections  

Extractor 

Fig. 2 Typical System (SEM2 Shown) 

Red 

Blue 

White 

Grey 

Black 

Green/Yellow 

Brown 

Orange 

Yellow 

Purple 

Fig. 4 SEM 1 / SEM 2 
Electrical Connections 

Fig. 5 SEM 7 / SEM 8 
Electrical Connections 

Fig. 3 Terminal Colour Positions 

Remote Motor 

Cable Assembly 

(Orange/Yellow link 

wire is included)

 

Remote Motor 

Cable Assembly 

(Orange/Purple link 

wire is included)

 

Summary of Contents for CAFE MODERNE

Page 1: ...draught shutter For wall mounted motors an inline backdraught shutter is recommended 3 EXTRACTION PERFORMANCE The primary influence on the overall performance of the extractor is the design of the ducting which takes the exhaust air from the extractor to the outside The duct route should be a prime consideration during the initial stages of the kitchen design We do not recommend recirculating air ...

Page 2: ...circulating air installations and they should be avoided wherever possible see section 3 If your extractor has been adapted for recirculation not our standard configuration then adequate provision must be made for the exhausted air to return into the kitchen equivalent to 150mm round duct e g Purchase of a special chimney with vents ducting to a vent in the room or finishing the chimney short of t...

Page 3: ... be fed from a 230Vac single phase electrical supply using a switched spur fitted with a 3A fuse The spur should be located adjacent to the hood cooker so that the supply can be disconnected from the hood using the switch The means of disconnection from the supply must have a minimum contact separation of 3mm in all poles Alternatively a means of disconnection in the fixed wiring according to the ...

Page 4: ...ith the latch held open Once the filter is in position release the lever allowing the latch to engage 6 2 Replacing Lamps The lamps are long life LED units and are not designed for end user replacement In the unlikely event of failure please call for assistance 7 SPECIFICATIONS All Models Supply Voltage 230V 50Hz Lighting 12V 2 6W LED Per Lamp 12V 2 6W See general arrangement drawings for lamp qua...

Page 5: ... Installation Operating Maintenance Instructions W1512 FMOD Moderne Range Hood O M Dec 16 docx Page 5 Fornair Figure 1 General Arrangement Drawing Front Figure 2 General Arrangement Drawing Rear 8 GENERAL ARRANGEMENT DRAWINGS ...

Page 6: ...Café Moderne Range Hoods Installation Operating Maintenance Instructions W1512 FMOD Moderne Range Hood O M Dec 16 docx Page 6 Fornair Figure 3 Hood Layout Explained Figure 4 Hood Baseplate Layouts ...

Page 7: ...1 Open Terminal Box Empty Terminal for Motor Connections Extractor Fig 2 Typical System SEM2 Shown Red Blue White Grey Black Green Yellow Brown Orange Yellow Purple Fig 4 SEM 1 SEM 2 Electrical Connections Fig 5 SEM 7 SEM 8 Electrical Connections Fig 3 Terminal Colour Positions Remote Motor Cable Assembly Orange Yellow link wire is included Remote Motor Cable Assembly Orange Purple link wire is in...

Page 8: ... Operating Maintenance Instructions W1512 FMOD Moderne Range Hood O M Dec 16 docx Page 8 Fornair Fourneaux de France Ltd Unit 3 Albion Close Newtown Business Park Poole Dorset BH12 3LL Tel 01202 733011 Email info fdef co uk www fdef co uk ...

Reviews: