Never attempt to dismantle the instrument so as to avoid the possibility of impairing its operational efficiency and

accuracy.

4.

To maintain the performance of the instrument, we recommend customers have their microscopes serviced

periodically by a factory authorized dealer/rep. For details, contact your nearest dealer or Labo America’s main

office in California.

Do not use aggressive organic solvent such as acetone for cleaning painted surfaces and plastic parts of

the microscope.

Never attempt to dismantle :

Periodical checking :

Caution:

5

Lx 100/200

Issue 1.0

5030000-795                                                           User Manual Lx-100/200                                        Printed on July,2013

Summary of Contents for Lx 100

Page 1: ...nstrument as well as to avoid injury while operating instrument understanding this manual completely before use is highly recommended User Manual Laboratory Microscopy R Lx 100 200 Part No 5030000 795...

Page 2: ......

Page 3: ...OF BRIGHTFIELD OBSERVATION PROCEDURE 14 9 ASSEMBLY 13 8 OPTIONAL ACCESSORIES 11 12 7 STANDARD COMPONENTS 10 5 8 UNPACKING YOUR MICROSCOPE Lx 100 4 Lx 200 7 3 6 Lx 100 2 SAFETY INFORMATION 2 5 1 INTRO...

Page 4: ......

Page 5: ...feguards the turret system against any damage All positions are par centered and par focalised ensuring the highest level of accuracy The ball bearing mechanical stage allows smooth travel over a 76 x...

Page 6: ...ould the power cord come in contact with the microscopes base the power cord could short circuit 6 Always ensure that the grounding terminal of the microscope and that of the wall outlet are properly...

Page 7: ...or oil smudges wipe with cleaning cloth slightly moistened with a mixture of petroleum 85 and isopropanol 15 2 Do not attempt to use organic solvents to clean the microscope components other than the...

Page 8: ...is unsuccessful repeat using a solution of diluted hand soap liquid Remove any remaining residue with a dry cotton swab c To remove oil use a solution of diluted hand soap liquid initially If this do...

Page 9: ...r microscopes serviced periodically by a factory authorized dealer rep For details contact your nearest dealer or Labo America s main office in California Do not use aggressive organic solvent such as...

Page 10: ...lar Viewing Tube Revolving Nosepiece Objectives Mechanical Stage Coarse Fine Focusing Knob On off Switch X Y Movement control Knob Light Regulator Abbe Condenser Issue 1 0 5030000 795 User Manual Lx 1...

Page 11: ...Tube Revolving Nosepiece Objectives Mechanical Stage Coarse Fine Focus Knob On Off Switch X Y movement Control Knob Light Regulator Abbe Condenser Specimen Holder Aperture Iris Diaphragm ring Issue 1...

Page 12: ...UNPACKING YOUR MICROSCOPE Lx 100 5 Mirror attachment if ordered Power Cord Microscope Arm Observation tube R R Lx 100 200 8 Issue 1 0 5030000 795 User Manual Lx 100 200 Printed on July 2013...

Page 13: ...UNPACKING YOUR MICROSCOPE Lx 200 6 Lx 100 200 Mirror attachment if ordered Power Cord R R Microscope Arm Observation tube 9 Issue 1 0 5030000 795 User Manual Lx 100 200 Printed on July 2013...

Page 14: ...t fit to prevent any damage during transportation To remove an objective rotate it counterclockwise while gripping it with a rubber sheet etc to avoid any slippage Daylight blue filter Allen Wrench 3m...

Page 15: ...IRROR ABBE CONDENSER 4x IP SERIES OBJECTIVES 10x 40x BINOCULAR VIEWING BODY IP ACHROMAT LED 100x 1 25 Oil 4x 0 10 10x 0 25 40x 0 65 10x EYEPIECE WITH EYEGUARD 15x EYEPIECE WITH EYEGUARD BATTERY 100x L...

Page 16: ...croscope frame by aligning the mounting tab 2 Remove the daylight filter because it renders the image blue under natural light conditions 3 The reflection mirror fig 5 should be pointed toward anywher...

Page 17: ...e the parts that may drop such as the filter and specimen from the microscope frame Turn around the microscope to its back so that theAC inlet is visible 1 Use a flat head screw driver to open the fus...

Page 18: ...ective to be used in the light path and bring the specimen in focus Adjust the observation tube and eyepieces Adjust the interpupillary distance Adjust the dioptric setting Engage the required filters...

Page 19: ...the knob at this time Caution 1 Rotate the coarse adjustment knob 2 in anticlockwise direction to fully lower the stage 2 Open the bow shaped lever 3 outward by pulling lever handle 1 place the speci...

Page 20: ...ounterclockwise to lower the stage 3 When coarse focusing of the specimen is obtained an image is detected rotate the fine adjustment knob 2 for fine focusing The WD refers to the distance between eac...

Page 21: ...e eyepiece to 64 mark 2 While looking through the right eyepiece with your right eye rotate the coarse and fine adjustment knobs to bring the specimen into focus 3 While looking through the left eyepi...

Page 22: ...nd rotate the revolving nosepiece 1 so that the objective to be used is in line above the specimen Always use the ribbed grip to rotate the objective nosepiece 6 7 Adjusting the Condenser Position and...

Page 23: ...us 4 After use remove oil from the objective front tens by wiping with lens tissue slightly moistened with petroleum 85 and isopropanol 15 mixture Immersion Process Since air bubbles in the oil will a...

Page 24: ...h until it clicks The objective eyepiece condenser Clean them thoroughly and or specimen glasses are dirty Immersion oil is not used with an Use immersion oil immersion objective Bubbles are present i...

Page 25: ...slide is slipped from the slide Re position the slide in the slide holder holder Slide is of excessive thickness Use slide having thickness between 0 9 and 1 4mm 10 LED does not light LED is not moun...

Page 26: ...condenser daylight filter detachable N A 1 25 Aperture iris diaphragm Built in 7 Dimensions 255 0mm L x 227 0mm W x 375 23mm H 8 Electrical Battery 7 4V 1000mAH Charging time up to 5 hours with total...

Page 27: ......

Page 28: ...erica Inc 9135000 990A 12 2009 LABOMED and Lx 100 Lx 200 are registered trademarks of Labo America Inc With a policy of continuous development Labo America Inc reserves the right to change design and...

Reviews: