background image

 

11/13/06 

 

 
Avoiding Damage to the Instrument 

 

1. For proper ventilation, leave at least 10 cm of space behind the instrument, and at 
least 5 cm of space on each side. 
2. Do not operate the power supply in high humidity environments (> 95%), or where 
condensation may occur. 
3. To avoid condensation after operating the power supply in a cold room, seal the unit 
in a plastic bag and allow at least 2 hours for the unit to equilibrate to room temperature 
before removing the bag and operating the unit. 

 
Symbols   

 

Used on the ENDURO 300 Volt Power Supply to indicate an area where a 
potential shock hazard may exist. 

 

 

Package Contents 

Component                          Quantity

   

ENDURO 300 Volt Power Supply   

1 each 

Instruction Manual   

 

 

 

1 each 

Extra Fuse 

 

 

 

 

 

1 each

 

Power Cord   

 

 

 

 

1 each 

Warranty Card  

 

 

 

 

1 each 

Quick Reference Card     

 

 

1 each 

 

Upon Receiving the Instrument 

Examine the unit carefully for any damage incurred during transit. Any damage claims 
must be filed with the carrier. The warranty does not cover in-transit damage. 

To ensure safe, reliable operation, always operate the ENDURO 300 Volt 
Power Supply in accordance with the manufacturer’s instructions. 
Always wear protective gloves and safety glasses when working in a 

laboratory environment. See Safety Information and Warranty 
Information in this manual.

 

Summary of Contents for Enduro E0303

Page 1: ...11 13 06 300 Volt Electrophoresis Power Supply Catalog Number E0303 110Volt E303 230V 230Volt...

Page 2: ...rview 6 Description of Buttons and Switches 6 Getting Started 7 Important Guidelines 8 Operation 8 Choosing Limiting Parameter Settings 9 Troubleshooting 11 Repair and Maintenance of 300V Power Supply...

Page 3: ...the risk of electrical shock to the user Please follow the guidelines below and read this manual in it s entirety to ensure safe operation of the unit The ENDURO 300 Volt Power Supply has been design...

Page 4: ...upply to indicate an area where a potential shock hazard may exist Package Contents Component Quantity ENDURO 300 Volt Power Supply 1 each Instruction Manual 1 each Extra Fuse 1 each Power Cord 1 each...

Page 5: ...odes Constant Voltage 1V increment settings Constant Current 1 mA increment settings Crossover Automatic Display type Backlit LCD Graphic type Display size 53 64 x 15 64 mm W x H Pause function Yes Sa...

Page 6: ...n be used simultaneously the ENDURO 300 Volt Power Supply is designed to efficiently handle multiple electrophoresis gel tanks and use a small amount of lab space The ENDURO 300 Volt Power Supply offe...

Page 7: ...values Getting Started Installing the ENDURO 300 Volt Power Supply 1 Check the label located near the AC inlet to ensure that the unit is compatible with locally provided voltage 2 Place the ENDURO 30...

Page 8: ...e Use the START PAUSE and STOP keys to switch on and off the power to the output jacks Recommendation The duration of electrophoresis can be defined in time hours minutes When using this or any electr...

Page 9: ...most electrophoresis methods resistance increases during the run Limiting the voltage provides the following advantages The same voltage setting can be used regardless of the number or thickness of ge...

Page 10: ...row keys to set either voltage V or current mA parameters to the appropriate values 4 Press the MODE key to choose the TIME parameter and use the Up Arrow Down Arrow keys to set the duration hours min...

Page 11: ...is removed from the pre cast gel buffers are prepared correctly and the recommended volume of buffer is added to the electrophoresis unit High voltage application is set to run on a very low current...

Page 12: ...is supplied with the 300Volt Power Supply For additional fuses contact Labnet s Technical Service department To replace the fuse 1 Turn off the main power switch at the rear of the 300V Power Supply a...

Page 13: ...run Buffer leaking in a connected system Excessive temperature increase Excessive buffer evaporation Loose connection in a connected system Amperage set to low Change in constant mode Voltage changes...

Page 14: ...determined by the gel system the resistance can vary over the course of an electrophoretic separation Voltage The velocity with which an ion moves in an electric field will vary in proportion to the...

Page 15: ...11 13 06...

Page 16: ...l Inc warrants that this product will be free from defects in material and workmanship for a period of three 3 years from date of purchase If a defect is present Labnet International will at its optio...

Page 17: ...your responsibility to decontaminate the equipment in case of biological chemical and or radiological contamination so as to protect from health hazards the persons involved in the disposal and recycl...

Reviews: