LM3510 Print & Apply Label Applicator
USER'S MANUAL
Page 52
Made in the U.S.A.
© 2019 LABELMILL
11/01/2019 Model LM3510
DESCRIPTION OF I/O
LEGEND
24V OPT:
24V OPTO INPUT WITH INTERNAL 24V COMMON
OH:
HIGH CURRENT OUTPUT Rated @ 500ma
All user inputs and outputs are
“SINKING”
type. Example in order for a status light to illuminate for “Run Status
Ok” the light should be wired between pins #1 & #8 on the
“DB-15 Light Bar/Aux.”
Connector.
Status display legend.
INPUTS
OUTPUTS
S
P
H
A
F
V
T
SMART
TAMP
PRODUC
T
SENSOR
HEAD
UP
TAMP
SENSOR
AIR ASSIST
SOL
FLAG
SOL
VACUUM
SOL
TAMP
SOL
0 = OFF X = ON
REMOTE TRIGGER CONNECTOR
(PRODUCT SWITCH)
4 pin Amp
P1
PIN #
ADDRESS
+24 VDC
1
TRIGGER INPUT
2
X0,0
24 COM
3
4
REMOTE TRIGGER CONNECTOR
(PRE-PRINT PRODUCT SWITCH)
4 pin Amp
P1-A
PIN #
ADDRESS
+24 VDC
1
TRIGGER INPUT
2
X0,1
24 COM
3
4
TAMP SOLENOIDS CONNECTOR
9 pin Amp
P2
PIN #
INPUT/
OUTPUT
ADDRESS
TAMP SOL
1
O
Y0,3
VACUUM SOL
2
O
Y0,2
TAMP HEAD UP SW IN
3
I
X0,2
24 COM
4
+24 VDC
5
FLAG SOL
6
O
Y0,1
AIR ASSIST SOL
7
O
Y0,0
SMART TAMP IN
8
I
X0,3
AUX OUT 7
9
O
Y0,4
3-25