LM3510 Print & Apply Label Applicator
USER'S MANUAL
Page 44
Made in the U.S.A.
© 2019 LABELMILL
11/01/2019 Model LM3510
QUICK START
1. Inspect applicator system and verify all cables are installed properly.
2. Web system with labels.
3. Turn power switch on.
4. Press “PROG”
5. Press down arrow
6. Enter Defaults
7. Press Up Arrow
8. Defaults are now set
9. Down arrow to Tamp Setup
10. Set tamp duration to .500 and set Head up switch to “N.O.”
11. Arrow down to Cycle Type
12. Set cycle type to “Tamp before feed”
13. System is now ready for set up of advanced features and options.
SETUP OF KEY FEATURES
HOW TO SET UP AN ASYNCHRONOUS APPLICATION
•
“TAMP” WITHOUT A ENCODER
Determine the following and select it in the software
1. Type of application mode.
2. Tamp before or after feed (before feed is standard)
3. Enter a value in the tamp duration (start with 00.200)
4. Set head up limit switch, normally open is standard
5. Use the product delay to “MOVE” the label on the product
The asynchronous application mode is used to apply labels to products that are either stationary or moving at a
constant speed when the label application is to take place.
•
“BLOW” WITHOUT AN ENCODER
Determine the following and select it in the software
1. Type of application mode.
2. Blow before or after feed (before feed is standard)
3. Enter a value in the tamp duration (start with 00.10)
4. Set head up limit switch to NO TAMP SWITCH
5. Use the product delay to “MOVE” the label on the product
The asynchronous application mode is used to apply labels to products that are either stationary or moving at a
constant speed when the label application is to take place.
3-17