LM3510 Print & Apply Label Applicator
USER’S MANUAL
Page 29
Made in the U.S.A.
© 2019 LABELMILL
11/01/2019 Model LM3510
•
PASSWORD
The PASSWORD is used to lock the menus of the control. This option is used to prevent unauthorized access to
variable data. When shipped from the factory, the pass word is to 7074 and NO MENUS are locked. The
password cannot be changed.
•
PRODUCT SENSOR
This is an external device that when “activated” starts the application cycle.
PROGRAMMABLE BLOCKS:
Product Delay – delays the application of the label (xx.xxx) seconds after the sensor has been activated.
Detector Lockout – Distance before the system looks for a re-trigger when using an encoder
Sensor Trigger – designates whether the product sensor is activated at the leading or trailing edge of the
product.
On Debounce – allows a small delay to be programmed in to prevent false triggering on the
leading
edge of
the product.
Off Debounce - allows a small delay to be programmed in to prevent false triggering on the
trailing
edge of
the product.
Multiple Feed – how many labels are applied to one product with one signal.
Interval Delay – amount of time in seconds between multiple fed labels Note: only active if quantity 2 or higher
DISTANCE USED WITH ENCODER ONLY OPTION
Dist 0 to 2 – used to set the position of the
first
label to be applied in “Multiple Feed” applications.
Dist 0 to 3 –used to set the position of the
second
label to be applied in “Multiple Feed” applications.
Dist 0 to 4 –used to set the position of the
third
label to be applied in “Multiple Feed” applications.
Dist 0 to 5 Dist 0 to 6 Dist 0 to 7 Dist 0 to 8 Dist 0 to 9
Dist 0 to 10 – used to set the position of the
tenth
label to be applied in “Multiple Feed” applications.
•
TAMP SET UP
This is used to adjust the different variables related to the tamp cycle.
PROGRAMMABLE BLOCKS:
Tamp Duration – used to adjust the time that the tamp cylinder valve is actuated. (0.000 to 9.999)
Flag Duration – used to adjust the time the flag jaws are held open after label application. (00.00 to 99.99)
Head Up Limit Switch – type:
normally open-
standard, normally closed, none
Head Up Debounce – Debounce is used to allow time for the tamp cylinder to settle on return (00.00 to 01.00)
Vacuum Release – Used to release label when tamping on light products.
Vacuum Delay On – Used to reduce label flutter when feeding large labels while tamping.
Tamp Sync Logic – Output on (normal) or Off (reverse) when tamp cylinder is up.
•
AUX TAMP SET UP (OPTIONAL)
This is used to adjust the different variables related to the secondary tamp cycle.
Secondary tamp utilized on a two stage corner wrap.
PROGRAMMABLE BLOCKS:
Tamp duration – used to adjust the time that the secondary tamp cylinder valve is actuated. (0.000 to 9.999)
Product Delay – delays the activation of the secondary tamp (xx.xxx) seconds after the sensor has been
activated.
3-02