7
4.3) DIGITAL PROGRAM SELECTOR ET-DSEL
Pressing briefly the button
, select the automatic door operating mode.
Whenever the button is pressed, you switch from a work program to the next.
The work programs which can be selected using the button
are described below
Automatic unidirectional exit only program
To disable entry detection on external Radar input.
Open door program
The door remains motionless in the position of complete opening.
Manual free door
Automatic operation is disabled and the door can be opened manually.
Automatic bidirectional program
The door automatically opens after an opening command.
Automatic unidirectional entry only program
To disable exit detection on internal Radar input.
Night lock program
The door can only be opened through the OPEN input or using the remote control, if any.
Operation of other buttons located on the panel of the program selector ET-DSEL
Partial opening
, used only in a double leaf door automation
To activate partial opening, press briefly the button
;
the symbol on the display indicates that the function is on.
In a dual leaf door, only the first leaf (Master) opens if the opening command is given from the internal or
external radar inputs.
Partial opening only operates in bi-directional, unidirectional, and open door automatic programs.
To disable partial opening, press again briefly the button
.
F2
It can have two distinct functions, depending on the setting of the automation.
a) Disables spring actuated door reclosing after a manual opening.
With F2 off, the door closes, with F2 on, the door remains stationary after a manual opening.
b) Disables step by step operation
(If enabled in the settings on the electronic control unit of the automation)
Press briefly the button F2 to disable step by step operation and enable the automatic closure of the door.
The symbol F2 lights up on the display.
To enable step by step operation, press again the button F2, the symbol F2 turns off on the display.
F1
Door opening command
Pressing the F1 button will open the door.
The button F1 may open the door even when the "NIGHT LOCK" work program is selected, if the