P a g e

 | 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

These instructions are to be considered as a rapid guide for installation of the FAAC 950N2 for 
both a single door installation or double door installation with On Door Safety Sensors and a 
check for opening/closing speeds along with the Hold Open time. We have included references 
where to find relevant wiring information for the fitting of Safety Sensors to protect the swept 
area  of  door/doors  as  specified  by  specified  by  the  Risk  Assessment  undertaken  by  the 
installer. The installer should still familiarise themselves with the full manual and the safety 
information  contained  within.  (available  at 

https://www.faac.co.uk/door/swinging-

doors/950-swing-door-operator

Summary of Contents for 950N2

Page 1: ...g with the Hold Open time We have included references where to find relevant wiring information for the fitting of Safety Sensors to protect the swept area of door doors as specified by specified by the Risk Assessment undertaken by the installer The installer should still familiarise themselves with the full manual and the safety information contained within available at https www faac co uk door...

Page 2: ...fixings for the material that you are fixing the operator to In General 60mm of Softwood 40mm of Hardwood 10mm of Aluminium or 6mm of Steel STEP 3 Once the operator and arm are mounted to the door and header connect the main power to the 950N2 ensure that the earth is securely connected See below STEP 4 Depending on the arm used adjust DIPSWITCH 2 accordingly as per below Once adjusted DL4 on the ...

Page 3: ...closed to fully open If using the trimmers please press SW1 on Logic board as in Step 4 At this point the door should be operational and a short across Terminals 10 11 15 or 17 and COM should trigger the automation of the door This should also illuminate DL2 DL3 DL7 or DL9 respectively STEP 7 Nearly all installations will require the use of On Door Safety Sensors be it the more basic XPB ON s XPB ...

Page 4: ...e Step 5 above for location details Please note that Factory default is in the OFF position STEP 3 Plug the KP Evo into the operator that you designate to be the SLAVE i e not receiving the opening commands Using the KP Evo go to Spanner Programming and then into Intercom see below and performing the following configuration changes Set Function to 2 Leaves Set Master Slave Nr to 2 Slave Unplug KP ...