background image

Copyright © 2016 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved. 
Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited. 

80-9316-2531-020 Rev 1

1

ASSA ABLOY

#7

1/4-20

Spring Power Adjustment Screw
1601 Series Only

"BC" Valve

Pinion Cap

Closer
Size
Stamp

"L"Valve

"S"Valve

Standard Components

Optional Components

4

Closer Body

Co

ver

Sleeve Nut and Bolt

Thru Bolt and Grommet Nut

Drill 9/32 thru from Closer Side

3/8 Drill other side

Drill 9/32 thru from Closer Side

3/8 Drill other Side

(Optional)

Metal

Wood

1618A Parallel

Arm Bracket

CA

UTION

CA
UTION

An  Incorrectly  installed  or  improperly  adjusted 
door  closer  can  cause  property  damage  or 
personal  injury.  These  installation  instructions 
should  be  followed  to  avoid  the  possibility  of 
misapplication or misadjustment.

Non Hold Open Models

Sized

(Sizes 3,4)

1603BC
1604BC

Adjustable

(Sizes 1 thru 6)

1601

Tri-Style

Installation Instructions

Non Handed Door Closer

1600 Series

Regular Arm/Top

Jamb Shoe

Main Arm

Connecting Rod

Forearm
Screw

Arm Slide

Arm Assembly

1688

Plate

NOTE:

  For special applications a separate 

door and frame preparation template is 
packed with these instructions. Use this 
instruction sheet for installation sequence 
and closer adjustments only.

Doors should be hung on ball bearing or 
anti-friction hinges.

A separate door stop is recommended.

Door and frame must be properly 
reinforced.

Adjust closing time speed between 3 and 7 
seconds from 90° to 0°.

These door closers should NOT be 
installed on the exposed side (weather 
side) of exterior doors.

Left Hand Door - LH
Right Hand Reverse - RHR

Right Hand Door - RH
Left Hand Reverse - LHR

Right Hand Door - RH
Left Hand Reverse - LHR

Top Jamb

Installation

See Page 5

Regular Arm

Installation

See Page 2

Parallel Arm

Installation

See Pages

3 & 4

Top Jamb

Installation

See Page 5

Right Hand Door - RH
Left Hand Reverse - LHR

Regular Arm

Installation

See Page 2

Left Hand Door - LH
Right Hand Reverse - RHR

Left Hand Door - LH
Right Hand Reverse - RHR

Parallel Arm

Installation

See Pages

3 & 4

Weaker

-

Stronger

+

Machine Screws

#7 Drill, 1/4-20 Tap

Self Drilling Screws

Wood and Metal

For Wood drill 3/16 hole
      

3/16" Pilot hole
required

ASSA ABLOY