background image

RADAR TRAINING SYSTEM
MODEL 8096

8

Figure 18. The Radar Active Target (RAT) Training System,
Model 8096-4

Figure 19. Effect of barrage noise jamming produced by the
jamming pod trainer of the RAT Training System as observed on
the Lab-Volt radar PPI display.

Figure 20. Stealth accessories in the RAT Training System allow
reduction of the jamming pod trainer’s radar cross section.

range gate relative to the echo signal of the target to be
acquired. When the range gate straddles the target echo
signal, the lock mode can be activated and the target is
automatically tracked in range and azimuth by the
system.

Range tracking is achieved by means of the split

range-gate technique, whereas angle tracking is
accomplished using lobe switching (sequential lobing).
In addition to the fully automatic tracking mode, several
useful ECCM features are available, such as a
switchable lobing rate, a range tracking rate limiter in the
range loop, manual control of either the range loop or the
azimuth loop while the system is locked onto a target,
and leading-edge range tracking. The computer-based
interface of the tracking radar allows control of these
functions and offers the same other possibilities as for
the pulse radar system (visualization of the system's
block diagrams, connection of virtual probes in the on-
screen block diagrams, observation of signals on the
built-in oscilloscope, fault insertion, etc.).

The Radar Active Target (RAT) Training System,

Model 8096-4, is used in conjunction with the three
previous subsystems (Models 8096-1, 8096-2, and
8096-3) to train students in the principles and scenarios
of EW. This is a truly unique system that places real-
time, safe, and unclassified EW demonstrations into the
hands of students. The RAT Training System consists of
an active jamming pod trainer, an elaborate set of
accessories, and a comprehensive student manual.

The jamming pod trainer is a Self-Screening Jammer

(SSJ) target that can perform direct or modulated noise
jamming (see Figure 19) as well as repeater jamming. It
includes a remote controller to select the type of
jamming and set the jamming parameters. The jamming
pod trainer and the included accessories are designed
for use with the Lab-Volt radar to implement real EW
situations. This provides an effective means of
introducing students to a real-time jamming situation that

necessitates a response, that is, the use of an
appropriate ECCM to prevent losing track of the target.

The RCS and ISAR Measurement Training System,

Model 8096-5, adds on to the Basic Radar Training
System, Model 8096-1, to form a computer-based,
pulse-mode system that can measure the radar cross
section (RCS) of targets as well as produce ISAR
images of targets (see Figures 21 to 23).

Summary of Contents for 8096

Page 1: ...Finally subsystem 8096 8 introduces students to the basic principles and operation of synthetic aperture radar SAR The Radar Training System uses patented technology to detect and track passive target...

Page 2: ...on jamming capabilities C Chaff cloud simulation C Radar cross section RCS measurement C Inverse synthetic aperture radar ISAR imagery capability C Phased array antenna C Operation as a Synthetic Aper...

Page 3: ...llowing types of clutter and interference can be generated sea clutter rain clutter second trace echo noise and pulse interference The Radar Processor Display consists of a reconfigurable training mod...

Page 4: ...the radar processing functions and adjust other parameters of the radar such as the video gain detection threshold etc see Figure 7 C control the radar display functions such as the PPI display mode...

Page 5: ...e of radar which is implemented Figure 7 Computer based control of the radar processing functions and operating parameters Figure 8 Computer based control of the radar display functions Figure 9 Windo...

Page 6: ...ls can be observed on the built in oscilloscope by connecting virtual probes to test points in the on screen block diagrams Figure 12 The Data Monitor is a powerful tool designed to study the various...

Page 7: ...parabolic antenna a joystick type hand controller a set of accessories and a student manual Installation of the Radar Tracking Training System is very simple insert the interface module in the RTM mo...

Page 8: ...diagrams connection of virtual probes in the on screen block diagrams observation of signals on the built in oscilloscope fault insertion etc The Radar Active Target RAT Training System Model 8096 4 i...

Page 9: ...ed The system can also generate high resolution ISAR images of much larger targets when the shortest pulse width is used Because the system is based on pulse operation it does not need to be operated...

Page 10: ...ively The trainer includes a phased array antenna a beam steering control module the necessary cables and a comprehensive student manual that deals with the principles of electronically steered antenn...

Page 11: ...Positioning System Model 9607 1 included in the Basic Radar Training System and an antenna motion control module SAR controller Target radar echoes produced during a complete antenna scan are sampled...

Page 12: ...lance Track While Scan Processing Troubleshooting the Digital MTD PPI Processor Volume 4 Tracking Radar 38545 00 Familiarization with the Tracking Radar Manual Tracking of a Target Automatic Range Tra...

Page 13: ...SOR DISPLAY ADD ON MODEL 8096 2 QTY DESCRIPTION ORDERING NUMBER 4 1 Power Supply 9408 00 1 Reconfigurable Training Module 9431 10 1 Analog Digital Signal Combiner 9630 00 1 Data Acquisition Interface...

Page 14: ...and Accessories 9690 D0 1 Monitor 9691 00 1 RCS ISAR Measurement Training System User Guide 39102 E07 RADAR PHASED ARRAY ANTENNA TRAINER ADD ON MODEL 8096 6 QTY DESCRIPTION ORDERING NUMBER 6 1 Phased...

Page 15: ...n EW demonstrations Model 9601 Power Supply Antenna Motor Driver The Power Supply Antenna Motor Driver is the physical base for the Basic Radar Training System Several modules of the system are design...

Page 16: ...nerates a command signal for output to the antenna motor driver The controller also generates azimuth information required by other system modules Unregulated DC power is automatically supplied to the...

Page 17: ...the target in X and Y On the target controller either manual control of target position and speed or one of four preprogrammed trajectories can be selected Two three digit displays give a readout of t...

Page 18: ...es contains all of the cables and accessories necessary for operation of the Basic Radar Training System Model 8096 1 These include SMA flexible cables BNC cables a DB9 cable an antenna motor driver c...

Page 19: ...l these signals using a conventional oscilloscope DC power is automatically supplied to the Analog Digital Signal Combiner when it is installed into the RTM Model 9631 Data Acquisition Interface The D...

Page 20: ...Computer is a Windows based computer with the LVRTS software installed two monitors and a dual output display adapter video card compatible with Microsoft DirectX version 9 or later The Radar Host Com...

Page 21: ...from misconnections within the system Test points are available on the module s front panel to observe the signals on the BNC connector inputs and outputs using a conventional oscilloscope DC power i...

Page 22: ...r The repeater which consists of an amplifier and a programmable delay line amplifies and delays the intercepted signal By transmitting this signal back to the radar and gradually increasing the delay...

Page 23: ...S 8096 5 RCS AND ISAR MEASUREMENT TRAINING SYSTEM AND 8096 8 SAR TRAINING SYSTEM Model 9610 RCS ISAR Measurement Interface The RCS ISAR Measurement Interface contains additional RF circuitry that allo...

Page 24: ...9611 SUBSYSTEM 8096 5 RCS AND ISAR MEASUREMENT TRAINING SYSTEM Model 9690 D Connection Leads and Accessories The Model 9690 D Connection Leads and Accessories contains a low RCS target support with a...

Page 25: ...assive limiters two low loss long SMA cables a 30 dB SMA attenuator a DB25 cable and a microwave absorbing pen SUBSYSTEM 8096 8 SYNTHETIC APERTURE RADAR SAR TRAINING SYSTEM ADD ON TO 8096 5 Model 9614...

Page 26: ...ntuitive user interface that provides all the controls and settings required to operate the Lab Volt synthetic aperture radar as well as to display fine SAR images Model 9690 F Connection Leads and Ac...

Page 27: ...d Y Voltage Range 8 to 8 V PPI Output Z TTL Azimuth Input TTL On Screen Test Points 8 Faults 4 Model 8096 2 Radar Processor Display Digital Pulse Radar MTD Processor Functions Moving Target Detection...

Page 28: ...ectable 1 2 and 5 ns Variable 0 6 to 5 5 ns Maximum Peak Power 200 mW Angular Accuracy 0 25E Model 8096 8 Synthetic Aperture Radar SAR Training System13 Operating Frequency 9 4 GHz Actual Aperture Bea...

Page 29: ...regulated DC Output Protection Circuit breaker Antenna Motor Driver Input Voltage Range 10 to 10 V PWM Output Voltage Range 24 V to 24 V max Physical Characteristics Dimensions H x W x D 104 x 687 x 3...

Page 30: ...Current 2 A 0 8 A Target Table Positioning Accuracy 0 5 cm 0 2 in Target Controller Speed Range 0 to 30 cm s 0 to 11 8 in s Programmed Trajectories 4 External Voltage Range 5 to 5 V External Input Im...

Page 31: ...nge 8 to 10 GHz RF Amplifier Maximum Gain 22 dB On Time per Pulse 150 ns Limiters Type Diodes Voltage Limits 1 V RF Input and Output Impedance 50 Sync Input TTL Physical Characteristics Dimensions H x...

Page 32: ...ut Power 0 5 dBm typical Impedance 50 Pulse Generator Pulse Width Ranges 1 2 5 1 to 5 ns Trigger Input TTL Output Level 300 mV Output Impedance 50 Faults 10 switch insertable Test Points 10 Physical C...

Page 33: ...ut Interface Analog Outputs 4 Voltage Range 10 to 10 V Impedance 600 Digital Outputs 4 TTL Test Points 8 Physical Characteristics Dimensions H x W x D 114 x 110 x 209 mm 4 5 x 4 3 x 8 2 in Net Weight...

Page 34: ...9614 02 9614 00 9620 10 9620 11 9620 12 9620 10 9620 11 9620 12 9620 10 9621 10 9621 11 9621 12 9621 10 9621 11 9621 12 9621 10 9630 00 9630 00 9630 00 9630 00 9630 00 9630 00 9630 00 9631 00 9631 00...

Page 35: ..._____________________________________________________ _____________________________________________________________________________________________________ ____________________________________________...

Page 36: ...ion facility has received the ISO 9001 certification Lab Volt reserves the right to make product improvements at any time and without notice and is not responsible for typographical errors Lab Volt re...

Reviews: