Page 5
Model Nomenclature
SECTION 1
GENERAL INFORMATION
1.A Introduction
1.B Warranty
1.C
Model Identification
N
EO
T
HERM
Commercial Boilers and Water Heaters
NOTE: Throughout the content of this manual,
the NeoTherm will be referred to as a ‘unit’.
unit = NeoTherm
LAARS Heating Systems NeoTherms are covered by a
limited warranty. The owner should complete the warranty
registration at www.Laars.com.
All warranty claims must be made to an authorized
LAARS Heating Systems representative. Claims must
include the serial number and model (this information
can be found on the rating plate), installation date, and
name of the installer. Shipping costs are not included in
the warranty coverage.
This manual provides information necessary for the
installation, operation, and maintenance of LAARS
Heating Systems NeoTherm boilers and water heaters.
Read it carefully before starting the installation.
All application and installation procedures should
be reviewed completely before proceeding with the
installation. Consult the LAARS Heating Systems
factory, or local factory representative, with any
problems or questions regarding this equipment.
Experience has shown that most operating problems
are caused by improper installation.
NeoTherm is protected against over pressurization. A
pressure relief valve is included with each NeoTherm.
Some NeoTherms may require that the PRV be
installed prior to filling the system. Refer to Figures 2-9
for PRV locations.
Consult the
Rating Plate
on the side of the unit. The
following information describes the Model Identification
(Model Nomenclature).
(1-2)
Model Series Designation
N T = NeoTherm
(3)
Usage
H = Hydronic
V = Volume Water
(4-6)
Size
1 5 0 = 150,000 BTU/hr input, NTV only
1 9 9 = 199,000 BTU/hr input, NTV only
2 8 5 = 285,000 BTU/hr input, NTV only
3 9 9 = 399,000 BTU/hr input
5 0 0 = 500,000 BTU/hr input
6 0 0 = 600,000 BTU/hr input
7 5 0 = 750,000 BTU/hr input
8 5 0 = 850,000 BTU/hr input
(7)
Fuel
N = Natural Gas
P = LP Gas
(8)
Options Code
X = Standard US
J = CSD-1, FM, GAP,
(U.S. size 500-850 only)
C = Standard Canada
D = CSD-1 (Canada 500-800 only)
E = OUTDOOR (U.S.)
F = OUTDOOR
(Canada NTH 399-850 only)
G = CSD-1, OUTDOOR
(U.S. 500-850 only)
H = CSD-1, OUTDOOR (
Canada 500-850 only
)
(9)
Pump Options
N = Pump included
(N/A for outdoor NTV 750 & 850)
X = No pump
W= HLW w/ Pump
(NTV only)
L = HLW w/out Pump
(NTV only)
(10)
Revision
3 = Third version
v
1
2
3
4
5
6
7
8
9
10
N
T
3
N
T
N - Natural
Indoor Units
X - No pump
3 - Third
1
5
0
P - Propane
X - Standard U.S.
N - Pump included
1
9
9
C - Standard Canada
(N/A for outdoor
H - Hydronic
2
8
5
J - CSD-1 (U.S. 500-850 only)
NTV 750 & 850)
Boiler
3
9
9
D - CSD-1 (Can 500-850 only)
L - Opt. HLW no pump
V - Volume
5
0
0
Outdoor Units
(NTV only)
Water
6
0
0
E - Standard U.S.
W - Opt. HLW w/ pump
7
5
0
F - Standard Canada
(NTV only)
8
5
0
G - CSD-1 (U.S. 500-850 only)
(N/A for outdoor
H - CSD-1 (Can 500-850 only)
NTV 750 & 850)
OPTIONS
REVISION
PUMP OPTIONS
SERIES
USAGE
SIZE
MBTU/h
FUEL
Summary of Contents for NEOTHERM NTH
Page 4: ...LAARS Heating Systems ...
Page 36: ...Page 36 Figure 22 Hydronic Piping Single Boiler Zoning with Circulators LAARS Heating Systems ...
Page 52: ...Page 52 Figure 36 Ladder Diagram 7 H Ladder Diagram LAARS Heating Systems ...
Page 100: ...Page 100 Parts Illustration 4 Internal Components Sizes 750 850 LAARS Heating Systems ...
Page 102: ...Page 102 Parts Illustration 6 Gas Train Components Sizes 600 850 LAARS Heating Systems ...