11
The
LM250/LM1000
is a high performance product. It is used mainly in the processing minerals.
6.
Working Instructions
6.1
General
6.2
Starting the milling process
•
Set the parameters as described before
•
Open the lid of the machine and put in the sample on top of the puck in the bowl
•
Close the machine lid and press start on the display.
6.3
Stopping the milling process
•
Stop the milling operation by pressing the emergency switch.
•
Pressing stop on the display
•
When the milling time elapses, the milling process is automatically ended. The display is reset to the last
set value.
The milling process can only be started, when the hood is closed, the power is connected and
when the air pressure is high enough.
Do not open the hood during the milling process, also not by force.
Do not mill inflammable or explosive samples! For these kind of samples, please contact
LAARMANN for special features.
Please note that the properties and therefore the dangerous nature of your sample, can change
during the milling process.
When removing and opening the bowl, always wear protective gloves. There is a danger of
burning the hands.
LM250/LM1000 PULVERISER RING MILL MANUAL