22
For HELP, call La-Z-Boy
®
Spas at 1.800.465.2933.
Operational Checks
CAUTION:
Do not turn on any pump until your spa is properly filled with
water. Running any pump without water in your spa can cause
IMMEDIATE damage, which is not covered by the guarantee!
By now you have rechecked your spa / hot tub mechanical connections and filled it
with water to about 1” above all jets by adding cold tap water (if equipped) through the
pre-filter (if equipped). Turn on power to the spa / hot tub at the main breaker panel
and test the operation of the electrical system. If you encounter a problem, please
reference the troubleshooting guide on page 52.
1. Turn on the breaker and test the operation of the Ground-Fault Circuit Interrupter
(GFCI) breaker by pushing the small button. This should automatically trip the spa /
hot tub circuit breaker. Only if pushing this button successfully trips this circuit
breaker should you reset this breaker and proceed to the next step.
DANGER:
If this breaker does not trip, immediately call your electrician.
Do not use your spa / hot tub!
2. Go to the topside control panel and look at
the display. The system goes through a brief
startup sequence after which Pump 1 starts
in filtration mode and the panel displays the
current water temperature.
3. Press the Pump 1 button
. You should hear the first AquaFlex Massage
pump turn on a higher speed, see water circulating in the spa, see the icon swirl on
the display, and see CO in the Personal AquaFlex Massage Control (see page 41).
CAUTION:
If water does not flow from the jets after 2 minutes, turn pow-
er off at the main panel and bleed air from the system (see
page 51). Turn power on again. Sometimes momentarily turn-
ing a pump off/on will prime it. Only do this four times
.
Figure 9 – Topside Control Panel
®