17
english
The display shows
xxx°C hh:mm
LA SAN MARCO
where hh = current time in hours (0 ÷ 23)
mm = current time in minutes
lA SAN MARCO = customer's name as desired
STOPPING
To stop the dosage function, keep the
K5gR1
key pressed first, followed immediately by the
K3gR1
key.
2°
1°
To switch to the IDlE ON status, press the
K3gR1
key only.
7.2 Dispensing
COFFEE CyClE
DISPENSING
In the idle-on status, press one of the four doses keys for the unit you wish to use for dispensing (for example,
K1gRx
). both the dispensing solenoid valve
eVx
and the
PUMP
are energised, starting up the dispensing
phase.
both the pump and the solenoid valve will remain activated until the quantity of product programmed previ-
ously is achieved (volumetric meter pulses).
The lED relating to the chosen dose stays on for the entire duration of coffee dispensing.
K1GRx
The display shows
Espresso
During dispensing, the display shows an indication of the dose dispensed (English version)
1 espresso
2 espressos
1 Coffee
2 Coffees
Continuous
Tea
steam