ADJUSTING GRINDING

In order to achieve finer or coarser grinding, the adjustment disk located under the hop-
per must be adjusted using the relevant handle.
In order to increase the coarseness of the ground coffee, the disk must be rotated clock-
wise; to decrease, turn the disk anticlockwise.

The disk remains in the chosen position without having to be locked in place.
The adjustment must be performed with the motor on, and preferably without any
coffee between the grinding blades.
Grind small amounts of coffee in order to determine the optimal degree of fineness.
Before checking the fineness of the ground coffee, grind some doses of coffee to
fill the duct between the grinding area and the outlet. This operation must be done
whenever the grinding setting has been changed in order to empty the duct of the
previous ground coffee.
The change of the grinding setting might vary the weight of the doses. Therefore
adjust the doses only after the grinding setting.
In the grinder-doser version, if the coffee comes out of the espresso coffee
machine very quickly, it means the coffee is ground too coarse. Viceversa, if it
comes out too slowly, it means the coffee is ground too fine. Nonetheless, bear in
mind that there are many conditions liable to influence the correct supply, such as
the weight of the portions, the compacting, the espresso machine settings, and the
cleaning of the filters.

COFFEE DOSE ADJUSTMENT

In order to adjust the size of the portion dispensed, use the push button controls
located on the lid of the funnel.
After having set the optimal degree of fineness, check the weight of the dose with
a digital precision scale. In order to adjust the dose press the push button “MENU”
for 3 seconds; the display will blink.

COARSER GRINDING

FINER GRINDING

Summary of Contents for SUPER JOLLY

Page 1: ...l description 3 4 Packaging 3 5 Disposal 3 6 Use 4 7 Installation and wiring 4 8 Operation of the appliance 5 9 Warnings regarding operation 8 10 Safety devices 8 11 Warnings regarding safety 9 12 Noi...

Page 2: ...MENSIONS H A H B C A B C H B D A C H B D A C H B D A C A B C D H mm 195 263 240 420 610 212 inches 73 4 101 2 91 2 161 2 24 81 4 SUPER JOLLY GRINDER DOSER MAJOR GRINDER DOSER ROBUR ROYAL GRINDER DOSER...

Page 3: ...dispose of the packaging materials according to the laws in force Should you decide not to use the appliance any more remember to unplug it so that it cannot be used and then cut the cable in the poin...

Page 4: ...e the voltage and frequency values of the supply mains correspond to the ratings indicated on the label featuring the appliance s technical data The wall socket must be fitted with an efficient earth...

Page 5: ...filter holder on the filter holder fork push the push button on the left indicating one cup to grind and dispense a single dose the push button on the right indicating two cups to grind and dispense...

Page 6: ...order to empty the duct of the previous ground coffee The change of the grinding setting might vary the weight of the doses Therefore adjust the doses only after the grinding setting In the grinder d...

Page 7: ...A blinking of the display will confirm the data have been saved and the exit from the adjusting program Use a digital precision scale to check again the weight of the dose and if necessary repeat abov...

Page 8: ...The appliance s motor is protected against overheating resulting from overcurrents by a thermal overload protection which when tripped cuts off the power supply to the motor Should the protection trip...

Page 9: ...ng adjustment and must not be removed by the user under any circumstances COFFEE OUTLET GUARD The coffee outlet guard must always be fixed to the doser using the relevant screws which must never be re...

Page 10: ...to contact with the internal or external parts of the appliance Never put ground coffee in the hopper intended only for coffee beans Do not tamper with the appliance Do not tug on the supply cable to...

Page 11: ...erson nel must be called in to perform periodical maintenance including detailed checks of the state of those components subject to wear The state of the grinding blades must be checked periodically K...

Page 12: ...s and the entire grinding system with a brush and a dry cloth After having placed the top blade container back into place screw the adjust ment ring and insert in models fitted with one the tamper pro...