Programming sequence

Barista Menu

• 

Coffee Boiler 1 Switching on/off

• 

Coffee Boiler 2 Switching on/off

• 

Coffee Boiler 3 Switching on/off

• 

Coffee Boiler 1 Temperature

• 

Coffee Boiler 2 Temperature

• 

Coffee Boiler 3 Temperature

• 

Steam Boiler Temperature

• 

Clock Adjust

Programming Sequence

• 

Language

• 

Temperature Measurement Units (°F - °C)

• 

User name

• 

Coffee Boiler 1 Temperature

• 

Coffee Boiler 2 Temperature

• 

Coffee Boiler 3 Temperature

• 

Steam Boiler Temperature

• 

Clock Adjust

• 

Auto On/Off

• 

Cup Heating

• 

Pumps Setting for Automatic Fill

• 

Steam Boiler Automatic Fill

• 

Pump Setting for Tea Water

• 

Coffee Boiler 1 Temperature Offset

• 

Coffee Boiler 2 Temperature Offset

• 

Coffee Boiler 3 Temperature Offset

• 

Total Doses

• 

Filter Alarm

Operating Procedure:

 with the coffee machine 

on

, press and 

hold the jog wheel for 5 seconds and the Barista Level 

menu will appear. 

Operating Procedure:

 First hold the knob for 3 seconds to 

achieve the OFF status, then realease it and

 

 press and 

hold it again for an additional 5 seconds. The Technician 

Level menu will appear. 

Description of the Levels

Technical Menu

Summary of Contents for strada ep

Page 1: ...EP Operating Software Manual V1 0 ...

Page 2: ...fications 2 Definition of Model 4 Installation 6 Operating the Espresso Machine and Preparing Coffee 7 Preparing Other Hot Drinks 9 Preventative Maintenance andWeekly Cleaning 10 De Commissioning and Demolition 11 NOTE The Software Programming Manual follows the Operating Manual Strada EP Operating Manual ...

Page 3: ...e functions it has been designed and built for Any other application is inappropriate and dangerous 12 Using any electrical device requires that certain fundamental rules be observed In particular do not touch the device with wet or humid hands and feet do not use the device while having no shoes on your feet do not use extension cords in bath or shower rooms do not unplug the device from the powe...

Page 4: ...10 Steam Wand 11 Removable Drain Tray 12 Waste Water Hose Holder 13 Programming Jog Wheel14 14 Drain Tray Grate 15 USB Key Connection For additional information on electronics and software programming please see the section entitled Software Programming This operating manual refers exclusively to the below model of our own manufacture Strada 3 group Electronic Paddle 3EP 1 Common Dimensions Weight...

Page 5: ...st at a pressure of 18 bar and has an operating pressure of 9 bar The following is a list of effective volume and power ratings according to the number of groups installed 3 groups 3 x 1 3 liters 3 x 800 Watts Covers are installed at either end of the cylindrical tank and on one of them there is housing for the water heating elements The temperature of the coffee boiler is maintained by an electro...

Page 6: ...r at elevated temperature Water temperature over 125 F 52 C can instantly cause severe burns or death from scalding Coffee Boiler 200 F 93 3 C Steam Boiler 260 F 127 C WASTE DRAIN POWER SUPPLY CORD MAIN SWITCH AND ELECTRICAL SUPPLY CONNECTION WATER FILTRATION SOFTNER MAIN WATER SUPPLY VALVE OPTIONAL WATER PUMP AND MOTOR FOR STEAM BOILER WATER CONNECTIONS BRAIDED HOSE OPTIONAL WATER PUMP MOTOR POWE...

Page 7: ...er inlet direct to the water filter T fitting and the Steam Boiler to the water pump outlet using one of the supplied stainless steel braided hoses Then connect the water pump inlet to the water filter softener outlet NOTE The differential pressure water pump is a volumetric pump and has been designed to be used exclusively with cold water Make sure that water is always present while the pump is o...

Page 8: ...gauge Once the pump stops check the display the message Coffee Boiler Filled should be displayed Push the Encoder Knob to confirm that the preceding procedures are complete The installation is now complete and the espresso machine should be heating to operating temperatures 2 Waiting for the Espresso Machine to Heat to Operating Temperature During this time it may happen that the pointer of the co...

Page 9: ...rewing coffee 5 General Notes for Coffee Preparation The potafilters must remain heated since they are partially isolated from the group due to the rubber gasket between them This can be accomplished by leaving the portafilters installed on the machine when not in use The portafilters may also be actively heated This procedure may be carried out by activating one of the brew buttons to flush hot w...

Page 10: ... move the container up and down just enough to dip the nozzle end in and out of the milk until you get the right amount of foam Gradually pour the foamed milk over warm espresso for a fresh cup of cappuccino In order to prevent heated liquid from being sucked back into the steam boiler it is recommended that the steam valve and steam wand be purged by opening the valve for a few seconds to allow s...

Page 11: ...CE THE MACHINE MUST NOT BE DIPPED IN NOR SPLASHED WITH WATER WHILE CLEANING FOR CLEANING OPERATIONS PLEASE FOLLOW THE INSTRUCTIONS LISTED BELOW VERY CAREFULLY CAUTION DO NOT REMOVE THE PORTAFILTER WHEN ITS REALTIVE GROUP IS BREWING HOT LIQUIDS THE COFFEE BOILER CONTAINS WATER AT ELEVATED TEMPERATURE WATER TEMPERATURE OVER 125 F 52 C CAN INSTANTLY CAUSE SEVERE BURNS OR DEATH FROM SCALDING WARNING T...

Page 12: ...g the espresso machine to the water pump Remove the reinforced plastic tubing on the drain connection At this point the machine may be removed from the bar being very careful not to drop it or crush your fingers The machine is made out of various materials and therefore if not intended for further service should be delivered to a recycling center which will select materials to be recycled or disca...

Page 13: ...arzocco com V1 0 Table of Contents 1 Strada Programming Introduction 2 Accessing Programming Mode 3 Description of the Programming Levels 4 Start Up Procedure 6 Strada EP Software Programming and Pressure Profile Manual ...

Page 14: ...the operator that an action has been started or that a process needs to begin The jog wheel is always located on the left of group one By turning it to the right it is possible to increase the value By turning it left it is possible to decrease the value and by pushing it down it is possible to scroll through the software menu enter functions or confirm first installation It is possible to turn on...

Page 15: ...plus additional parameters are available Factory Level Factory password needed Barista Level and Technician level parameters plus additional parameters are available To change any configurable parameter the operator must first enter the programming mode There are three levels of the programming mode that allow modification to specific parameters depending on the sequence that is followed Accessing...

Page 16: ...Temperature Steam Boiler Temperature Clock Adjust Auto On Off Cup Heating Pumps Setting for Automatic Fill Steam Boiler Automatic Fill Pump Setting for Tea Water Coffee Boiler 1 Temperature Offset Coffee Boiler 2 Temperature Offset Coffee Boiler 3 Temperature Offset Total Doses Filter Alarm Operating Procedure with the coffee machine on press and hold the jog wheel for 5 seconds and the Barista Le...

Page 17: ...m Boiler Level Timeout Language Temperature Measurement Units F C User Name Coffee Boiler 1 Temperature Coffee Boiler 2 Temperature Coffee Boiler 3 Temperature Steam Boiler Temperature Clock Adjust Auto On Off Cup Heating Pumps Setting Steam Boiler Automatic Fill Pump setting for Tea Water Coffee Boiler 1 Temperature Offset Coffee Boiler 2 Temperature Offset Operating Procedure First hold the knob...

Page 18: ...r turning on the espresso machine Please follow the procedures carefully to avoid any damage The espresso machine is now ON and information concerning the boiler and heating elements will appear The message at left will be displayed briefly This message indicates the revision level of the software installed in this espresso machine Start Up Procedures HAZARDOUS VOLTAGE DISCONNECT FROM POWER SUPPLY...

Page 19: ...ing the Espresso Machine Off This is the OFF setting used in normal operating conditions 4 The main switch should be turned to the OFF position during servicing or other conditions requiring the OFF position The following is the procedure for turning off the espresso machine Please follow the procedure carefully to avoid any damage This machine has two off settings One setting turns off all compon...

Page 20: ...utton drag each of the square markers on the curve to the desired locations Note you cannot drag a point left or right beyond the previous or next point Once a curve has had at least one point edited its color changes from red to blue and the number of edited curves for this group shown in the status box below the plot is incremented When you are satisfied with the curve you can click the CURVE up...

Page 21: ...group you have to specify which to plot using the up down boxes in the control box at the top of the plot Also displayed in the control box is the number of design profile that was used Manual Programming of the Pressure Profile Press and hold the button on the group where you wish to record the pressure profile then on the display the sentence PRO FILE N will flashing Now the machine is ready to ...

Page 22: ...LA MARZOCCO SRL Via La Torre 14 H Località La Torre 50038 Scarperia Florence ITALY T 39 055 849 191 F 39 055 849 1990 info lamarzocco com www lamarzocco com ...

Reviews: