System Requirements for PC use: 

The minimum system requirement for use of this “Heavy Weather” 
software is:  

 

  

Operating system: Windows 98 or above

 

Processor: Pentium 166 MHz or above

 

RAM: 32MB of RAM or above

 

Hard disk: 20MB free space 
CD-ROM drive 

 

For full details on operation and installation of the “Heavy Weather” 
software refer to the PC manual in PDF format on the CD-ROM. 

 

Features of the base station: 

• 

Receives and displays the DCF77 radio controlled time and date  

• 

Display of extensive weather data, in all cases with programmable 
alarm functions for certain weather conditions as well as records of 
all minimum and maximum values along with time and date of their 
recordings 

• 

Indoor and outdoor temperature and relative humidity displays in 
degrees Fahrenheit or Celsius (user selectable) 

• 

Indoor and outdoor relative humidity displays 

• 

Air pressure reading in inHg or hPa, absolute or relative (user select-
able) 

• 

Detailed display of rainfall data in 1 hour, 24 hours, total since last 
reset (user selectable in mm or inch) 

• 

Wind speed in mph, km/h, m/s, knots or Beaufort (user selectable) 

• 

Wind direction display with LCD compass as well as numerical (e.g. 
225°) and abbreviated characters (e.g. SW) 

• 

Wind chill temperature display 

• 

Dew point temperature display 

• 

Weather forecast display by weather icons (sunny, cloudy, rainy) 

• 

Weather tendency indicator 

• 

Storm warning alarm 

• 

LED back light 

• 

Simultaneous display of all weather data with individual settings by 
the user 

• 

COM port for easy connection to your PC 

• 

All the weather data from the base station and up to 175 sets of 
weather history data with user adjustable measuring intervals can be 
recorded and uploaded to your PC 

 

Features of the Thermo-Hygro Sensor 

The thermo-hygro sensor measures the outdoor temperature and 
relative humidity.  It also collects the readings from the rain and wind 
sensors before transmitting the data to the base station by wireless 
433MHz or by the 10 meter cable included in this set. 

 

Features of Wind sensor 

The wind sensor measures wind speed and wind direction and sends  
the data to thermo-hygro sensor which in turn transmits the data to 
the base station.  Operating power is taken from the thermo-hygro 
sensor using a 10 meter cable connection. 

 

Features of Rain sensor 

The rain sensor measures the rainfall and sends the data to thermo-
hygro sensor which in turn transmits the data to the base station.  
Operating power is taken from the thermo-hygro sensor by a 10 meter 
cable connection. 

 

3. Safety 

Notes 

 

• 

Damage caused by failure to comply with this instruction manual will 
invalidate any guarantee! The manufacturer and supplier will not be 
held liable for actions due to failure to comply with this instruction 
manual or from data inaccuracies that may occur with this product! 

 

• 

In case of harm or damage to a person or property caused by im-
proper handling or failure to comply with this instruction manual, the 
manufacturer and supplier cannot be held liable.   

 

• 

For reasons of safety and operation, alterations to this device are 
strictly prohibited. 

 

• 

To operate the weather station, use only supplied adaptor and batter-
ies of the recommended type. 

 

• 

Do not leave used-up batteries in the device as these may corrode 
and release chemicals that may damage the unit. 

 

• 

Inserting batteries in an incorrect polarity will cause damage to this 
product. 

 

• 

This product is not a toy kept out of the reach of children. 

 

• 

Do not depose new or used batteries to fire as they may explosion or 
release dangerous chemicals. 

 

• 

This product is not to be used for medical purposes or for public 
information. 

 

Summary of Contents for WS2300

Page 1: ...or office Please read this instruction manual thoroughly to fully understand the features and functions so that you can enjoy the safe and correct operation of this unique product 2 Intended Use Weath...

Page 2: ...he Thermo Hygro Sensor The thermo hygro sensor measures the outdoor temperature and relative humidity It also collects the readings from the rain and wind sensors before transmitting the data to the b...

Page 3: ...lder 2 x U bolts for mast holder 4 x Washers 4 x Nuts 1 x screw to fix main unit to the mast holder GB GB Battery compartment Socket for Adaptor Rain Sensor Main unit base and funnel 10 meter cable al...

Page 4: ...powered up a short beep will sound and all LCD segments will light up for about 5 seconds before it enters into a 15 minute learning mode to learn the sensors security code After the learning mode or...

Page 5: ...terval is changed to the new reading interval i e using cable con nection is every 8 seconds data reading interval or from 32 seconds 128 seconds intervals when using 433MHz depending on wind speed Us...

Page 6: ...e units meet with your distance requirements at the point of fixing Signals from the sensors can be received by the base station at points of mounting Radio controlled time signal can be received at t...

Page 7: ...he thermo hygro sensor would be the outer wall beneath the extension of a roof as this will protect the sensor from direct sunlight and other extreme weather conditions To wall mount use the 2 screws...

Page 8: ...RH high Wind chill alarm 10 0 C low 30 0 C high Dew point alarm 0 0 C low 30 0 C high Rainfall 24h alarm 50 0mm Rainfall 1h alarm 1 0mm Wind Speed 1km h low 100km h high Wind direction alarm None set...

Page 9: ...e one value given by various newspapers TV and radio broadcasting stations in their daily weather forecasts for their respective locations users can set the relative air pressure of the weather statio...

Page 10: ...IND key To toggle between the following settings Wind speed Wind direction Wind direction display in degrees ALARM key In normal mode to enter the alarm pro gramming mode In alarm programming mode to...

Page 11: ...ing The base station will continue to scan for the radio controlled time signal from 2am 6 am each day winter time or from 3am 6am summer time despite it being manually set During reception at tempts...

Page 12: ...er station allows for the follow ing 13 alarms modes to be set 1 Time alarm 2 Indoor temperature high alarm and low alarm 3 Outdoor temperature high alarm and low alarm 4 Indoor humidity high alarm an...

Page 13: ...more to toggle to the indoor humidity low alarm set mode 5 Press and hold the SET key to enter the indoor humidity low set ting values digits will start flashing and set the desired indoor humidity lo...

Page 14: ...ey once more to another alarm setting mode Pressure high alarm and low alarm setting 1 Press the ALARM key to enter the normal time alarm 2 Continue to press the ALARM key until you reach the pressure...

Page 15: ...ardless if that particular alarm has been set to the ON To deacti vate the BUZZER OFF press the MINUS key once more General Alarm Icon The general alarm icon on the bottom right corner of the LCD will...

Page 16: ...e Unit settings temperature pressure rainfall wind Air pressure offset for calculation of relative air pressure Weather picture threshold Storm warning threshold LCD contrast Alarm time Weather Alarm...

Page 17: ...too long Reduce distance between transmitters and receiver to receive signal High shielding materi als between the units thick walls steel con crete isolating alumi num foil and etc Find a different...

Page 18: ...om side to side Do not clean the funnel with the bottom half of the rain sensor attached nor the bottom part itself under running water This may bear the danger of water entering the unit s inner part...

Page 19: ...ly Thermo hygro sensor 2 x AA IEC LR6 1 5V or can draw power from the adapter if used Battery life using 433MHz approximately 12 months alkaline batteries recom mended Battery life using cable connect...

Reviews: