background image

 

20.  

Transmission Range 

 

The transmission distance from the thermo-hygro sensor to the base 
station in open space under optimum conditions is 25 meters.      
Although the signal transmission may travel though solid surfaces or 
objects, the following points should be avoided if possible: 

 

High frequency interferences of any kind. 

Constructions of any kind or trees. 

The distance of transmitter and receiver to conducting planes or 
object (including the human body or the ground) does influence 
the transmission characteristics and thus the transmission dis-
tance. 

Broadband interferences in municipal areas can reach levels 
reducing the signal/noise ratio over the entire frequency band, 
thus also reducing the transmission distance. 

Devices working close by (example a neighbor’s house) may 
also influence reception. 

Poorly shielded PCs can cause interferences that will reduce or 
in some cases stop reception 

 
 

21. Cleaning 

and 

Maintenance 

 

Clean the housing and screen of the base station only with a soft 
damp cloth.  Do not use abrasives or solvents. 

Ensure that the rain sensor does not collect leaves or other dirt 
by checking the funnel for blockages every now and then.  Also 
clean the seesaw of the sensor with a damp cloth and check by 
lightly tapping with your finger that it can move freely from side 
to side. 

- Do 

not

 clean the funnel with the bottom half of the rain sensor 

attached nor the bottom part itself under running water. This 
may bear the danger of water entering the unit’s inner parts and 
cause damages. 

Do not immerse the base station in water. 

Should there be damage to this product, please do not attempt 
to make any repairs.  Please take this unit to a qualified techni-
cian. Opening or improper handling of the units will invalidate 
any guarantee. 

 

 
 

22. Specifications 

 

Outdoor data 

Transmission Distance in Open Field: 

25 meters max. 

Temperature Range 

-

29.9°C to +69.9°C (show 

“OFL” if outside range) 

Resolution : 

0.1°C 

Measuring Range Rel. Humidity 

20% to 95% (if the relative 
humidity is less than 20% or 
greater than 95%, it will dis-
play 19% or 96%)

 

Rain Volume Display 

0 to 999.9mm (1h and 24h 
rainfall) 

 

0 to 2499mm (Total rainfall) 

Resolution : 

0.1mm 

Wind Speed 

0 to 180 km/h or 1 to 50 m/s 

Resolution : 

0.1m/s 

Wind Direction 

Graphic Resolution 22.5 
Degrees, Numerical Resolu-
tion, Letter format 

433MHz data transmission: 

Measuring interval  
thermo-hygro sensor 

32 sec (if wind factor>10m/s) 
or 128sec (if wind fac-
tor<10m/s) 10 minutes (if the 
base station fails to receive 
any data after 5 attempts in a 
row; all outdoor data read-
ings will display “---“, except 
for the rain value)

 

 

With wire data transmission: 

Measuring interval  
thermo-hygro sensor 

:   8 seconds  

 

Indoor data 

Pressure/ temperature 

4 times per minute 

Indoor Temperature Range 

:

 

-9.9°C to + 59.9°C (shows 
“OFL” if outside range) 

Resolution : 

0.1°C 

 

GB

GB

 

Summary of Contents for WS2300

Page 1: ...or office Please read this instruction manual thoroughly to fully understand the features and functions so that you can enjoy the safe and correct operation of this unique product 2 Intended Use Weath...

Page 2: ...he Thermo Hygro Sensor The thermo hygro sensor measures the outdoor temperature and relative humidity It also collects the readings from the rain and wind sensors before transmitting the data to the b...

Page 3: ...lder 2 x U bolts for mast holder 4 x Washers 4 x Nuts 1 x screw to fix main unit to the mast holder GB GB Battery compartment Socket for Adaptor Rain Sensor Main unit base and funnel 10 meter cable al...

Page 4: ...powered up a short beep will sound and all LCD segments will light up for about 5 seconds before it enters into a 15 minute learning mode to learn the sensors security code After the learning mode or...

Page 5: ...terval is changed to the new reading interval i e using cable con nection is every 8 seconds data reading interval or from 32 seconds 128 seconds intervals when using 433MHz depending on wind speed Us...

Page 6: ...e units meet with your distance requirements at the point of fixing Signals from the sensors can be received by the base station at points of mounting Radio controlled time signal can be received at t...

Page 7: ...he thermo hygro sensor would be the outer wall beneath the extension of a roof as this will protect the sensor from direct sunlight and other extreme weather conditions To wall mount use the 2 screws...

Page 8: ...RH high Wind chill alarm 10 0 C low 30 0 C high Dew point alarm 0 0 C low 30 0 C high Rainfall 24h alarm 50 0mm Rainfall 1h alarm 1 0mm Wind Speed 1km h low 100km h high Wind direction alarm None set...

Page 9: ...e one value given by various newspapers TV and radio broadcasting stations in their daily weather forecasts for their respective locations users can set the relative air pressure of the weather statio...

Page 10: ...IND key To toggle between the following settings Wind speed Wind direction Wind direction display in degrees ALARM key In normal mode to enter the alarm pro gramming mode In alarm programming mode to...

Page 11: ...ing The base station will continue to scan for the radio controlled time signal from 2am 6 am each day winter time or from 3am 6am summer time despite it being manually set During reception at tempts...

Page 12: ...er station allows for the follow ing 13 alarms modes to be set 1 Time alarm 2 Indoor temperature high alarm and low alarm 3 Outdoor temperature high alarm and low alarm 4 Indoor humidity high alarm an...

Page 13: ...more to toggle to the indoor humidity low alarm set mode 5 Press and hold the SET key to enter the indoor humidity low set ting values digits will start flashing and set the desired indoor humidity lo...

Page 14: ...ey once more to another alarm setting mode Pressure high alarm and low alarm setting 1 Press the ALARM key to enter the normal time alarm 2 Continue to press the ALARM key until you reach the pressure...

Page 15: ...ardless if that particular alarm has been set to the ON To deacti vate the BUZZER OFF press the MINUS key once more General Alarm Icon The general alarm icon on the bottom right corner of the LCD will...

Page 16: ...e Unit settings temperature pressure rainfall wind Air pressure offset for calculation of relative air pressure Weather picture threshold Storm warning threshold LCD contrast Alarm time Weather Alarm...

Page 17: ...too long Reduce distance between transmitters and receiver to receive signal High shielding materi als between the units thick walls steel con crete isolating alumi num foil and etc Find a different...

Page 18: ...om side to side Do not clean the funnel with the bottom half of the rain sensor attached nor the bottom part itself under running water This may bear the danger of water entering the unit s inner part...

Page 19: ...ly Thermo hygro sensor 2 x AA IEC LR6 1 5V or can draw power from the adapter if used Battery life using 433MHz approximately 12 months alkaline batteries recom mended Battery life using cable connect...

Reviews: