4)  Using the PLUS(+) or MINUS (-) keys select the desired wind 

direction and use the SET key to confirm or cancel each direction 
input 

5)  Press ALARM key to confirm and press the MIN/MAX key to re-

turn the normal display mode or press the ALARM once more to 
toggle to another alarm setting mode. 

 

Storm warning alarm setting 

Unlike the other weather alarms, the storm warning alarm is set by 
entering the main manual setting mode as follows: 
10) Press the SET key to enter the manual setting mode 
11) Continue to press the SET key until the Storm warning icon 

flashes (tendency arrow flashing downwards with the pressure 
values flashing) 

12) Set the desired hPa pressure value (3 hPa - 9 hPa) using the 

PLUS(+) or MINUS(-) keys 

13) Press the MIN/MAX key to confirm and return to the normal dis-

play. 

 

Storm warning alarm ON/OFF 

After storm warning alarm setting, the next mode to appear after 
pressing the SET key is the storm warning ON/OFF.  Use the 
PLUS(+) or MINUS(-) key to change the status to  AON or AOFF. 
Default setting is ON: 
 
Should the air pressure drop equal or below the pre-set hPa value 
within the last 6 hour period, then the downward tendency arrow will 
flash as an indication of possible storm. The base station will take 
hourly measurements as a point of reference.  The storm-warning 
indicator will stop flashing once the air pressure becomes more sta-
ble. 
 

Master Alarm – BUZZER OFF 

The time and all the weather alarms may have buzzer sound set to 
OFF by holding the MINUS(-) key down for about 3 seconds in normal 
display mode and the BUZZER OFF icon appears on the bottom left 
of the LCD.  When the BUZZER OFF is displayed, the time and all 
other weather alarms when activated will only flash but not sound 
regardless if that particular alarm has been set to the ON. To deacti-
vate the BUZZER OFF, press the MINUS(-) key once more. 
 

General Alarm Icon 

The general alarm icon on the bottom right corner of the LCD will 
appear when any weather alarm is activated to show the user that a 
set weather condition has been reached. The activated alarm can be 
determined by checking the set alarm values against the MIN/MAX 
values reached. To deactivate the general weather alarm icon, press 
the ALARM key. 

 

Important 

When entering the alarm set mode for a specific weather or tempera-
ture condition, the corresponding alarm is automatically enabled (ON) 
when the SET key is pressed, regardless of its previous setting and 
the alarm value will flash to indicate that it has been activated.  Press 
the ALARM key to confirm the setting and continue pressing the 
ALARM key to toggle through each alarm mode until it returns to the 
normal display mode or press the MIN/MAX key at any time to exit the 
alarm setting modes. 

 

When a set weather alarm condition has been activated, that particu-
lar alarm will sound and flash for approximately 2 minutes but will 
continue to flash until weather conditions have become more steady. 

 

Weather Alarms 

The weather alarms are settable for when certain weather conditions 
are met according to the users requirements.  For example, the user 
can set the thresholds for the outdoor temperature to +40°C (high) 
and -10°C (low), whilste only enabling the high alarm and disabling 
the low alarm (i.e. temperatures <-10°C won’t trigger alarm, but tem-
peratures >+40°C will). 

 

Alarm setting  

Minimum 

Maximum 

Storm threshold 

3 hPa 

9 hPa 

Air Pressure 

920.0 hPa 

1080.0 hPa 

Outdoor Tempera-
ture 

-30.0°C +69.9°C 

Indoor Temperature 

-9.9°C. No alarm will 
sound if the minimum 
indoor temperature alarm 
is set below -9.9ºC. 

+59.9°C 

Humidity (all) 

20% RH 

95% RH 

Rainfall 24h 

0.0 mm 

1000 mm. 

Rainfall 1h 

0.0 mm 

1000 mm 

Wind 

0.0 m/s 

50.0 m/s 

Summary of Contents for WS2300

Page 1: ...or office Please read this instruction manual thoroughly to fully understand the features and functions so that you can enjoy the safe and correct operation of this unique product 2 Intended Use Weath...

Page 2: ...he Thermo Hygro Sensor The thermo hygro sensor measures the outdoor temperature and relative humidity It also collects the readings from the rain and wind sensors before transmitting the data to the b...

Page 3: ...lder 2 x U bolts for mast holder 4 x Washers 4 x Nuts 1 x screw to fix main unit to the mast holder GB GB Battery compartment Socket for Adaptor Rain Sensor Main unit base and funnel 10 meter cable al...

Page 4: ...powered up a short beep will sound and all LCD segments will light up for about 5 seconds before it enters into a 15 minute learning mode to learn the sensors security code After the learning mode or...

Page 5: ...terval is changed to the new reading interval i e using cable con nection is every 8 seconds data reading interval or from 32 seconds 128 seconds intervals when using 433MHz depending on wind speed Us...

Page 6: ...e units meet with your distance requirements at the point of fixing Signals from the sensors can be received by the base station at points of mounting Radio controlled time signal can be received at t...

Page 7: ...he thermo hygro sensor would be the outer wall beneath the extension of a roof as this will protect the sensor from direct sunlight and other extreme weather conditions To wall mount use the 2 screws...

Page 8: ...RH high Wind chill alarm 10 0 C low 30 0 C high Dew point alarm 0 0 C low 30 0 C high Rainfall 24h alarm 50 0mm Rainfall 1h alarm 1 0mm Wind Speed 1km h low 100km h high Wind direction alarm None set...

Page 9: ...e one value given by various newspapers TV and radio broadcasting stations in their daily weather forecasts for their respective locations users can set the relative air pressure of the weather statio...

Page 10: ...IND key To toggle between the following settings Wind speed Wind direction Wind direction display in degrees ALARM key In normal mode to enter the alarm pro gramming mode In alarm programming mode to...

Page 11: ...ing The base station will continue to scan for the radio controlled time signal from 2am 6 am each day winter time or from 3am 6am summer time despite it being manually set During reception at tempts...

Page 12: ...er station allows for the follow ing 13 alarms modes to be set 1 Time alarm 2 Indoor temperature high alarm and low alarm 3 Outdoor temperature high alarm and low alarm 4 Indoor humidity high alarm an...

Page 13: ...more to toggle to the indoor humidity low alarm set mode 5 Press and hold the SET key to enter the indoor humidity low set ting values digits will start flashing and set the desired indoor humidity lo...

Page 14: ...ey once more to another alarm setting mode Pressure high alarm and low alarm setting 1 Press the ALARM key to enter the normal time alarm 2 Continue to press the ALARM key until you reach the pressure...

Page 15: ...ardless if that particular alarm has been set to the ON To deacti vate the BUZZER OFF press the MINUS key once more General Alarm Icon The general alarm icon on the bottom right corner of the LCD will...

Page 16: ...e Unit settings temperature pressure rainfall wind Air pressure offset for calculation of relative air pressure Weather picture threshold Storm warning threshold LCD contrast Alarm time Weather Alarm...

Page 17: ...too long Reduce distance between transmitters and receiver to receive signal High shielding materi als between the units thick walls steel con crete isolating alumi num foil and etc Find a different...

Page 18: ...om side to side Do not clean the funnel with the bottom half of the rain sensor attached nor the bottom part itself under running water This may bear the danger of water entering the unit s inner part...

Page 19: ...ly Thermo hygro sensor 2 x AA IEC LR6 1 5V or can draw power from the adapter if used Battery life using 433MHz approximately 12 months alkaline batteries recom mended Battery life using cable connect...

Reviews: