background image

REMOTE

THERMO-SENSOR

433 MHz

TIME

DATE

WWWB

SUNRISE

MOON PHASE

SUNSET

INDOOR TEMPERATURE

TENDENCY

PRESSURE

rel

inHg

PRESSURE HISTORY

OUTDOOR TEMPERATURE

LO

MIN

HI

MAX

HUMIDITY

LOCATION

MOONSET

MO1

PM

PM

MIN

MAX

RH

%

HUMIDITY

RH

%

01

+7

+5

+3

+1

0

-1

-3

-5

-7

-1h

-3h

-6h

-9h

-12h

-18h

-24h

-30h

0

+0.2 +0.5

+1

+2

+4

%

RH

%

RH

2

R A D I O   C O N T R O L L E D

IN

OUT

ALARM

SET

SUN/

MOON

CH

+

GB

P.2

GB

P.3

INVENTORY OF CONTENTS

1. WS-8025SU-indoor weather station
2. TX4U-remote thermo/hygro (temperature/humidity) sensor
3. Instruction manual and warranty card

ADDITIONAL EQUIPMENT (not included)

1. Five fresh AA 1.5V alkaline batteries.
2. One wall-mounting screw (optional)

ABOUT WWVB (radio-controlled time)

The NIST (National Institute of Standards and Technology-Time and Frequency Division) radio station,
WWVB, is located in Ft. Collins, Colorado and transmits the exact time signal continuously throughout
the United States at 60 kHz. The signal can be received up to 2,000 miles away through the internal
antenna in the indoor weather station. However, due to the nature of the Earth's Ionosphere, reception
is very limited during daylight hours. The indoor weather station will search for a signal every night
when reception is best. The WWVB radio station derives its signal from the NIST Atomic clock in
Boulder, Colorado. A team of atomic physicists continually measure every second of every day to an
accuracy of ten billionths of a second a day.  These physicists have created an international standard,
measuring a second as 9,192,631,770 vibrations of a Cesium 133 atom in a vacuum.  For more
information about WWVB please see the NIST website at
http://www.boulder.nist.gov/timefreq/stations/wwvb.htm

QUICK SET-UP GUIDE

Hint : Use good quality Alkaline Batteries and avoid rechargeable batteries.

1. Have the indoor weather station and remote thermo/hygro sensor 3 to 5 apart.
2. Batteries should be out of both units for 10 minutes.
3. Place the batteries into the remote thermo/hygro sensor first then into the indoor weather station.

(All remote thermo/hygro sensors must be started before the indoor weather station)

4. DO NOT PRESS ANY BUTTONS FOR 10 MINUTES.

In this time the indoor weather station and remote thermo/hygro sensor will start to talk to each other
and the indoor weather station will show both the indoor temperature and humidity and the outdoor
temperature and humidity.  If the indoor weather station does not display all values after the 10
minutes please retry the set up as stated above.  After all values are displayed for 10 minutes you can
place your remote thermo/hygro sensor outdoors and set your time.

The remote thermo/hygro sensor should be placed in a dry, shaded area. The remote thermo/hygro
sensor has a range of 200 feet. Any walls that the signal will have to pass through will reduce distance.
An outdoor wall or window will have 20 to 30 feet of resistance and an interior wall will have 10 to 20
feet of resistance. Your distance plus resistance should not exceed 200 ft. in a straight line.

TABLE OF CONTENTS

Topic

Page

Inventory of Contents/ Additional Equipment

3

About WWVB

3

Quick Set Up Guide

3

Detailed Set Up Guide

Battery Installation

4

Start Up Sequence

5

Explanation of LCD Information

6

Function Key Layout

6

Program Mode

6

Time, 12/24 Hour Mode and Date Setting

7

City Location Setting

7

U.S. City Codes

8

Canada City Codes

11

Mexico City Codes

11

Time Zone and Daylight Saving Time (DST) Setting

11

Weather Measuring Units

11

LCD Contrast

12

Features and Operation

Sun Rise/Set and Moon Rise/Set Calculation

12

Moon Phase

13

Minimum/Maximum Temperature/Humidity

14

Multiple Remote Transmitters

14

Remote Temperature Alarm

15

Comfort Indicator

15

Weather Forecast Icon and Pressure Trend

15

Weather Tendency Arrows

16

Storm Warning Alarm

16

Two Hour Air Pressure Tendency Chart

17

Barometric Air Pressure Reading

17

Air Pressure History Bar Chart

17

Mounting

17

Maintenance and Care

19

Troubleshooting Guide

19

Specifications

19

Warranty Information

20

Summary of Contents for WS-8025SU

Page 1: ...1 PM PM MIN MAX RH HUMIDITY RH 01 7 5 3 1 0 1 3 5 7 1h 3h 6h 9h 12h 18h 24h 30h 0 0 2 0 5 1 2 4 RH RH 2 R A D I O C O N T R O L L E D IN OUT ALARM SET SUN MOON CH FCC ID OMO 01TX transmitter OMO 01RX...

Page 2: ...Contents Language Page English 2 French 22 Spanish 44...

Page 3: ...for 10 minutes 3 Place the batteries into the remote thermo hygro sensor first then into the indoor weather station All remote thermo hygro sensors must be started before the indoor weather station 4...

Page 4: ...al is captured it will override any time and date set to the time zone selected 5 Once the time and date are set the indoor weather station will conduct a search every night at midnight and correct to...

Page 5: ...USA default factory setting 4 Press and release the or button to select the country USA United States CAN Canada MEX Mexico 5 Press and release the SET button to advance to the state setting USA only...

Page 6: ...select the city closest to your location abbreviated by airport code if applicable 11 Press and release the SET button to advance to the time zone setting skip steps 1 and 2 in section D if continuin...

Page 7: ...to the barometric air pressure calibration setting 9 The air pressure reading will now flash 29 91 inHg 1012 8 hPa as default 10 Press and release the or button to adjust to the correct relative air...

Page 8: ...icker change in the forecast icon In other words if the setting is 0 06 inHg the forecast icon will change if the air pressure changes by at least 0 06 inHg within a six hour period This is useful as...

Page 9: ...ty to disregard all weather forecasting for 12 24 hours after the unit has been set up reset or moved from one altitude to another i e from one floor of a building to another floor In areas where the...

Page 10: ...large metal objects can reduce the range Place all units in their desired location and wait approximately 15 minutes before permanently mounting to ensure that there is proper reception If the indoor...

Page 11: ...ter the initial time date set the indoor weather station only requires one full minute of clear reception each night SPECIFICATIONS Radio controlled Time Signal WWVB 60 kHz from Ft Collins CO Indoor w...

Page 12: ...cond Indoor humidity Every 20 seconds Outdoor temperature Every 5 minutes Outdoor humidity Every 5 minutes Transmitter reading update within sensor Outdoor temperature Every 1 minute Outdoor humidity...

Page 13: ...d materials for all repairs covered by this warranty If necessary repairs are not covered by this warranty or if a product is examined which is not in need or repair you will be charged for the repair...

Page 14: ...IS PRODUCT IS NOT A TOY KEEP OUT OF CHILDREN S REACH This warranty gives you specific legal rights You may also have other rights specific to your State Some States do no allow the exclusion of conseq...

Page 15: ...Made in China All rights reserved This handbook must not be reproduced in any form even in excerpts or duplicated or processed using electronic mechanical or chemical procedures without written permis...

Page 16: ...ue la nature de l ionosph re de la terre la r ception est tr s limit e pendant l t La station m t o int rieure cherche un signal chaque nuit lorsque la r ception est la meilleure La station radio WWVB...

Page 17: ...ygro Transmitter Mounting Bracket Recent Battery Cover SIZE AA LR6 SIZE AA LR6 SIZE AA LR6 II S quence de d marrage A D marrage initial 1 Imm diatement apr s l installation des piles la station m t o...

Page 18: ...s quence du mode de programmation Remarque Si le pays programm n est pas les Etats Unis l tape 8 correspond la ville l tape 9 est le fuseau horaire etc 1 Heure 2 Minute 3 12 24 heures 4 Annee 5 Mois 6...

Page 19: ...est entr e dans la base de donn es Due la capacit m moire limit e 245 villes figurent sur la liste Chaque tentative a t faite pour fournir un endroit proche toutes les r gions d Am rique du Nord Les c...

Page 20: ...sur la touche SET la maintenir enfonc e pendant 1 seconde 2 Appuyer 9 fois sur la touche SET et le rel cher 3 Le fuseau horaire clignote maintenant bas sur la ville s lectionn e 4 Appuyer sur la touch...

Page 21: ...s sur le lieu entr en mode de programmation Pour visualiser un autre lieu et ou une autre date sans affecter la ville programm e et la date suivre la section A 2 dans Caract ristiques et fonctionnemen...

Page 22: ...r enfonc e pendant au moins une seconde D Capteurs de temp rature radio pilot s multiples Le WS 8025SU est capable de recevoir des signaux de 3 capteurs radio pilot s diff rents Ces capteurs radio pil...

Page 23: ...temps sera ensoleill sans nuages iii Nuages avec de la pluie indique que le temps va se d t riorer cela ne signifie pas que le temps sera pluvieux Fl che de tendance de pression b Les ic nes m t o cha...

Page 24: ...ra la derni re temp rature lue pendant 15 minutes Apr s 15 minutes sans r ception de signaux la temp rature radio pilot e affiche A Montage du capteur thermo hygro radio pilot Le capteur thermo hygro...

Page 25: ...040 hPa inHg relatifs r glables 28 60 inHg 30 45 inHg R glage de la sensibilit hPa 1hPa 4hPa Historique de la pression atmosph rique Pour les 30 derni res heures 0 1 1 3 6 12 18 24 et 30 heures Interv...

Page 26: ...de la Estaci n del Tiempo Sin embargo debido a la naturaleza de la Ionosfera de la tierra la recepci n es muy limitada durante las horas diurnas La Estaci n del Tiempo buscar la se al cada noche cuan...

Page 27: ...nsmitter Mounting Bracket Recent Battery Cover II Secuencia de Puesta en Funcionamiento A Initial Start 1 Inmediatamente despu s que las bater as han sido instaladas en la Estaci n delTiempo Interior...

Page 28: ...odidad Humedad en Interiores Hora en que se oculta la luna en el rea o ubicaci n seleccionada Hora de la aparici n o salida de la luna en el rea o ubicaci n seleccionada Fecha controlada por se ales d...

Page 29: ...gton OGC Kahului FSM Fort Smith PUB Pueblo WAI Waimea LIT Little Rock CT Connecticut IA Iowa TXK Texarkana HFD Hartford ALO Waterloo AZ Arizona DC District of Columbia DSM Des Moines FLG Flagstaff DCA...

Page 30: ...Guadalupe E Ajuste de Zona Horaria y Hora de Verano 1 Presione y sostenga la tecla SET por 1 segundo 2 Presione y suelte la tecla SET 9 veces 3 La Zona Horaria titilar ahora basada en la Ciudad selec...

Page 31: ...modo de programaci n Para ver otra localizaci n y o fecha sin afectar la localizaci n programada de la ciudad y fecha siga secci n A 2 in Caracter sticas y Operaci n 1 C lculo de Horas Diurnas y Minut...

Page 32: ...8025SU pueden recibir se ales de 3 sensores remotos diferentes Estos sensores remotos extras pueden comprarse a trav s del mismo distribuidor de esta unidad A TX4U monitorear la temperatura y humedad...

Page 33: ...cambian el tiempo no ha cambiado o el cambio ha sido lento y gradual f La sensiblidad del cambio de cono de pron stico es ajustada por el usuario en la secci n F de la Gu a Detallada de Puesta en Func...

Page 34: ...cie de montaje deseada c A trav s de los 2 agujeros para tornillos del soporte marque la superficie de montaje con un l piz d Donde haya marcado inicie los agujeros usando los tornillos suministrados...

Page 35: ...1 2 3 6 12 18 24 y 30 horas Intervalos de verificaci n de Datos Temperatura interior Cada 15 segundos Humedad interior Cada 20 segundos Temperatura al aire libre Cada 5 minutos Humedad al aire libre C...

Page 36: ...O ESTE PRODUCTO NO ES UN JUGUETE MANT NGALO FUERA DEL ALCANCE DE LOS NI OS Esta garant a le confiere derechos legales espec ficos Usted tambi n puede tener otros derechos espec ficos de su Estado Algu...