1/ FUNCTION DESCRIPTION 

 

5 kinds of weather forecast, BAR display in dynamic curve, pressure measurement, history record and trend display of pressure in the past 12 hours

 

 

Max/min value of indoor temperature and humidity 

 

Five channels in total. Three channels for outdoor temperature and humidity, one for wind speed and direction, and the other for rainfall.

 

 

Max/ min value and trend of outdoor wireless temperature and humidity.

 

 

Real-time outdoor wireless wind speed and direction, the average of wind speed, wind trend and max and min value of the wind information.

 

 

Outdoor heat index, dew point, chill coefficient.

 

 

Display the rainfall of current day; the current rainfall rate; Record of the past 1 hour, 24hours, 1 week and 1 month.

 

 

Perpetual calendar with moon phase, RCC DCF

 

 

Alarm, backlight, snooze 

2/ MAIN FUNCTION   

 

12 functional keys: -/RCC

+/

/

℉、

MODE

CHANNEL

MAX/MIN

SNOOZE/LIGHT

ALERT

HISTORY

RAINFALL

ALARM ON/OFF

HI/DP/CHILL

WIND. 

 

Automatically clock receiving (DCF) 

 

Daylight saving time. 

 

Time and perpetual calendar displaying. 

 

Two time format to be selected 12/24 hr.   

 

Single alarm, five minutes snooze function.   

 

Two temperature display format options (

 / 

). 

 

Indoor temperature and humidity displaying. 

 

Range of indoor temperature testing:    -10

~ 60

 (14 

 ~ 140

)    testing cycle: 30 seconds 

 

Range of indoor humidity testing: 20% ~ 95%. 

 

Max and min values of Indoor temperature and humidity. 

 

Three different wireless channels work together for three sets receiving of outdoor temperature and humidity. Range of temperature testing: -40 

 ~ 158 

; Testing cycle: about 1 

minute.  

 

The max and min of outdoor temperature and humidity. 

 

The up and low limit of indoor and outdoor temperature alarm.   

 

Indoor/ outdoor temperature trend.   

ENGLISH 

Summary of Contents for SM50PRO

Page 1: ... week and 1 month Perpetual calendar with moon phase RCC DCF Alarm backlight snooze 2 MAIN FUNCTION 12 functional keys RCC MODE CHANNEL MAX MIN SNOOZE LIGHT ALERT HISTORY RAINFALL ALARM ON OFF HI DP CHILL WIND Automatically clock receiving DCF Daylight saving time Time and perpetual calendar displaying Two time format to be selected 12 24 hr Single alarm five minutes snooze function Two temperatur...

Page 2: ...eric pressure changes in the past 12 hour BAR display of the atmospheric pressure in the past 12 hour Moon phase calculate Receiver can display low power index of 4 parts Receiver temperature sensor wind speed sensor rainfall sensor LED backlight 3 POWER AND RESET After put on the battery LCD will display three seconds with a sound of BI at the sametime start detecting temperature humidity and pre...

Page 3: ...nd humidity Enter relative pressure setting Enter relative wind setting Press once Confirm setting Ahead by one step Back by one step Time setting Hold Ahead by 8 steps second Back by 8 steps second Press once Confirm setting Ahead by one step Back by one step Alarm teyying Hold Ahead by 8 steps second Back by 8 steps second Press once Ahead by one step Back by one step Select the channel Confirm ...

Page 4: ...ess SNOOZE key stop alarm and into five minutes snooze mode 4 2 7 CHANNEL In normal mode press CHANNEL to switch RF channels CH1 CH2 CH3 cycle display In normal mode press CHANNEL key longer than 2 seconds clear all outdoor channel records outdoor temperature and humidity wind speed rainfall Channel set in the ALERT mode select the channel settings 4 2 8 RAINFALL In normal mode press RAINFALL to s...

Page 5: ... Press MODE to confirm the setting item and turn to next setting 5 Press once to ahead one step hold more than 2 seconds to ahead by 8 steps second 6 Press RCC once to back one step hold more than 2 seconds to back by 8 steps second 7 Without any effective handling more than 20 seconds will exit setting automatically 8 When into alarm setting the alarm will be on automatically 4 5 TEMPERATURE ALER...

Page 6: ... than 20 seconds will exit setting automatically 5 FUNCTION AND EFFECT 5 1 RF RECEIVING When power on it will automatically into RF receive for 3 minutes after temperature and humidity testing 3 minutes later into RCC receiving In normal mode press Channel more than 2 seconds to force clear all registration information of channels If the registered CH temperature does not receive any effective sig...

Page 7: ...and outdoor temperature is 70 C the lower limit is indoor 10 C outdoor 40 C When alarming relative temperature and alarming symbol is twinkling Temperature alarm buzzers Continue alarming 4 Bi per second Stop until the conditions meets alarm Stop alarm conditions Press any key to stop the temperature alarming alarm again the next minute Stop alarming when the temperature back to the range of setti...

Page 8: ...he piles must installation by respecting the polarity indicated on the apparatus and the pile An incorrect positioning can is to damage the apparatus is to cause escapes on the level of the pile is to the extreme to cause a fire or the explosion of the pile To ensure proper operation the batteries must be in good condition In case of abnormality in the functioning of the device put fresh batteries...

Page 9: ...ck that the wind vane is correctly oriented then press on the button TX picture 4 the system will consider this direction as being the default true north picture 3 Each time you replace the batteries of the anemometer or you change the location check through the method above that the wind vane is correctly oriented towards the true north Picture 1 N S Picture 3 Tx button Picture 4 ...

Page 10: ......

Reviews: