SOLAR-POWERED TRANSMITTER OPERATION MODES

 

 

(1) NORMAL MODE:  

 

 

NORMAL MODE occurs when the battery voltage is 2.5V or greater. 

 

It measures and transmits temperature / humidity (weather) data to the indoor receiver every 
8 seconds.  

 

It checks the brightness level of the surrounding environment every 5 seconds. 

 

It measures / transmits every 16 seconds if it detects a dark environment or if the battery 
voltage drops below 2.5V. 

 
 

(2) IDLE MODE: 

 

If the battery voltage drops below 2.4V, it commences IDLE MODE; the LCD turns off and it 
does not measure / transmit weather data. 

 

It checks the brightness level of the surrounding environment every 5 seconds. 

 

If battery voltage rises back to 2.5V or above, it returns to NORMAL MODE. 

 

If the environment remains dark for 72 hours, it commences STOP MODE. 

 

 
(3) STOP MODE (STANDBY): 

 

Occurs when the environment remains dark for 72 hours OR if you manually commence 
STOP MODE (standby) by covering the solar cell for 10 seconds and then press the RESET 
key one time. 

*NOTE: The LCD will display "

StP

" then turn off and commence STOP MODE. 

 

While in STOP MODE (standby), the LCD is off and the Sensor does not perform any normal 
operations. 

 

To resume normal operation, ensure the Sensor is in a bright environment (next to a 60W 
light bulb or similar condition) and press the RESET key to return to NORMAL MODE (battery 
voltage is higher than 2.5V). 

 

SOLAR MODE ON THE WEATHER STATION 

This weather station has green technology and a power-savings mode that reduces power consumption 
by monitoring and reacting to available lighting conditions.   

 

The surrounding environment brightness is checked every 5 seconds. 

 

LCD will automatically turn OFF if the environment is too dark. (It will appear blank) 

 

LCD will automatically turn ON if the environment is bright enough. 

 

No information will display when the LCD is OFF, but all the settings and operations will 
remain, except for the temperature and humidity measurements. 

 

NOTE

: This will occur no matter which type of battery you use. This is a 

Program Menu

 

feature. 

 

Turn this feature off and the LCD will stay on all the time. Enter the Program Menu and click 
through until you see SOL and ON flashing.  Press the PLUS button to turn Solar Mode OFF. 
The LCD will no longer go blank in low light situations. 

 

STOP MODE ON THE WEATHER STATION 

If the Weather Station is in a dark environment for 72 hours continually, the clock will go to the stop mode: 

  The most power saving condition.  

  The indoor solar display will not operate and the LCD will turn OFF.  

  Press any key to wake up the indoor solar display and re-activate the transmission with the 

solar transmitter. 

 

Summary of Contents for WS-6010U-IT

Page 1: ... Sensor LCD toggles temperature and humidity readings Transmits outdoor humidity temperature to indoor receiver using 915 MHz signals 200 FT wireless transmission range open air Built in rechargeable alkaline power cells store solar power for continuous operation No batteries necessary internal power cells cannot be replaced contact customer service for a replacement sensor Able to charge in low l...

Page 2: ...t apart for 15 minutes so the signal can lock in repeatedly Do not press buttons at this time NOTE The solar panel needs light from a 60W light bulb or brighter during the activation process Do not cover solar panel with hands or other objects TX62UTH IT transmitter RESET key NOTE Do not use sharp objects to press the RESET key Use a small dull pointed object or a straightened paper clip and gentl...

Page 3: ... bright environment next to a 60W light bulb or similar condition and press the RESET key to return to NORMAL MODE battery voltage is higher than 2 5V SOLAR MODE ON THE WEATHER STATION This weather station has green technology and a power savings mode that reduces power consumption by monitoring and reacting to available lighting conditions The surrounding environment brightness is checked every 5...

Page 4: ...Press and release the SET key to exit the setting mode and switch back to the normal display mode SOLAR MODE ON THE WEATHER STATION If the solar mode setting is ON The surrounding environment brightness is checked every 5 seconds LCD will automatically turn OFF if the environment is too dark LCD will automatically turn ON if the environment is bright enough No information will be displayed when th...

Page 5: ...The distance of the Weather Station or the Sensor should be at least 6 feet 2 meters away from any interfering sources such as computer monitors or TV sets 2 Avoid placing the Weather Station onto or in the immediate proximity of metal window frames 3 Using other electrical products such as headphones or speakers operating on the same signal frequency 915MHz may prevent correct signal transmission...

Page 6: ...r Sensor onto the bracket NOTE The mounting surface can affect the transmission range If for instance the Sensor is attached to a piece of metal it may then either reduce or increase the transmitting range For this reason we recommend not to place the unit on any metal surfaces or in any position where a large metal or highly polished surface is in the immediate vicinity garage doors double glazin...

Page 7: ...display is blank FACE DOWN Place the display face down on a clean cloth to prevent the solar panels from providing power UNPOWERED FOR 15 MINUTES It is important for the display to remain without power for at least 15 minutes NOTE Failure to allow a display to rest for 15 minutes can result in failure to connect with the outdoor sensor or missing segments on the display SENSOR FIRST GENTLY PUSH th...

Page 8: ...La Crosse Technology Ltd will repair or replace this product at our option and at no charge as stipulated herein with new or reconditioned parts or products if found to be defective during the limited warranty period specified above All replaced parts and products become the property of La Crosse Technology Ltd and must be returned to La Crosse Technology Ltd Replacement parts and products assume ...

Page 9: ...tact La Crosse Technology 2817 Losey Blvd S La Crosse WI 54601 The complete instruction manual is available at www lacrossetechnology com 6010 Le manuel d instruction complet est disponible sur www lacrossetechnology com 6010 El manual de instrucciones completo está disponible en www lacrossetechnology com 6010 Contact Support 1 608 782 1610 Product Registration www lacrossetechnology com support ...

Reviews: