background image

Model: T83653v2      www.lacrossetechnology.com/support        

Page | 9

  

Specifications 

Indoor

:

 

Temperature 
Range:

 

32°F to 122°F (0°C to 50°C) 

Humidity Range: 

1%-99% (RH) 

Interval: 

About every 30 seconds 

Outdoor

Temperature 
Range:

 

-40°F to 140°F (-40°C to 60°C) 

Humidity Range: 

1%-99% (RH) 

Distance:

 

Over 300 ft. (91 meters) RF 433MHz (open air) 

Power:

 

Forecast station  
Primary AC Power:  

5.0 volt AC 1.5A power adapter (included) 

AC/6 Adapter No.: 

HX09-0501500-AU

 

Optional/Battery  

Optional 3-AAA, IEC, LR3 batteries (not included) 

TX141TH-BCH 
Remote Sensor: 

2-AA, IEC, LR6 batteries (not included) 

Battery Life:

 

Forecast station 
Battery Backup: 

Battery life is over 12 months when using the AC 
adapter for primary power 

TX141TH-BCH 
Remote Sensor: 

Battery life is over 24 months when using 
reputable battery brands. 

Dimensions:

 

Forecast station:

 

5.91" L x 1.66" W x 4.84" H  
(150.1 x 42.2 x 122.9 mm) 

TX141TH-BCH 
Remote Sensor: 

1.57"L x 0.79"W x 5.12"H  (40 x 20 x 130mm) 

 

FCC Statement 

 
This equipment has been tested and found to comply with the limits for a 
Class B digital device, pursuant to part 15 of the FCC Rules. These limits 
are designed to provide reasonable protection against harmful 
interference in a residential installation. This equipment generates, uses 
and can radiate radio frequency energy and, if not installed and used in 

Summary of Contents for T83653v2

Page 1: ...Batteries 3 AAA BACK VIEW AC adapter HX09 0501500 AU USB Port BUTTONS Color Animated Forecast with Tendency Indoor Humidity Temperature with Trend and Alerts Indoor Comfort Statement Button Press for...

Page 2: ...r outside in a shaded location Transmission range is 300 feet 91 meters open air Restart If the outdoor temperature shows dashes unplug the AC adapter and remove batteries from the forecast station an...

Page 3: ...select the channel 1 2 or 3 before entering Alert Set Mode Press the ALERTS button to exit or wait 20 seconds without pressing buttons to return to normal time display Arm Disarm Temperature Humidity...

Page 4: ...ll flash In snooze mode press any button except ALARM to stop alarm for one day Note The alarm is crescendo sound The alarm sounds for two minutes and then will shut off completely USB Charge Port Cha...

Page 5: ...s the button to view readings on a different channel Remote Sensor Channels Auto Scroll Press the button to toggle between remote sensor channels when multiple sensors are used The forecast station wi...

Page 6: ...nd Down Arrows Rising Pressure Weather is Expected to Improve Steady Pressure Weather is Expected to Stay the Same Falling Pressure Weather is Expected to Worsen Temperature Humidity Trend Indicators...

Page 7: ...ll search for all remote sensors 6 Press the TX button on each remote sensor to transmit RF signal 7 When RF connection is established the temperature humidity for each of the selected channels will a...

Page 8: ...the batteries are installed with correct polarity and Remove batteries from equipment when it not to be used for an extended period of time Promptly remove expired batteries Do not expose to extreme...

Page 9: ...included Battery Life Forecast station Battery Backup Battery life is over 12 months when using the AC adapter for primary power TX141TH BCH Remote Sensor Battery life is over 24 months when using rep...

Page 10: ...located or operating in conjunction with any other antenna or transmitter Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must a...

Reviews: