21
Table 6. Various displays in Refresh Mode
Various displays (toggled by pressing DISPLAY key)
Stage in
Refresh mode
Voltage (V)
Current (mA)
*Time (hh:mm)
Capacity
(mAh/ Ah)
During
discharging
processes
Instantaneous
Battery voltage
Discharging
current
Discharging time
elapsed
Capacity during
discharging
During charging
processes
Instantaneous
Battery voltage
Charging current
Charging time
elapsed
Capacity
determined in
last time
discharging
Full stage
Instantaneous
Battery voltage
Trickle charging
current
Elapsed time of
last discharging
Maximum battery
capacity
determined in
discharging
22
Table 7. Various displays in Test Mode
Various displays (toggled by pressing DISPLAY key)
Stage in Test
mode
Voltage (V)
Current (mA)
*Time (hh:mm)
Capacity
(mAh/ Ah)
During charging
Charging current
Charging time
elapsed
“--- mAh”
During
discharging
Discharging
current
Discharging time
elapsed
“--- mAh”
During 2nd
charging
Charging current
2nd charging
time elapsed
Capacity of the
battery
determined in
discharging
Full stage
Instantaneous
Battery voltage
Trickle charging
current
Discharging time
elapsed
Capacity of the
battery
determined in
discharging
Note:
•
*The timer will be resumed and counted from 00:00 again after the time elapsed is
longer than 20 hours. (For example, 1:45 will be shown after the battery has been
refreshed for 21 hr and 45 min.)
23
•
In case the power source is shortly interrupted or terminated when the charger is
being operated, the operational mode will automatically be set to “Charge mode at
200 mA” to charge up the battery once the power source is back to normal, regardless
of the operating mode (Charge, Discharge, Refresh or Test) which has been selected
by user before.
CARE AND MAINTENANCE:
z
Extreme temperatures, vibration and shock should be avoided as these may cause
damage to the unit
z
When cleaning the displays and casings, use a soft damp cloth only. Do not wet the
exposed metal part of the charging unit. Do not use solvents or scouring agents as
they may mark the LCD and casing.
z
Do not spill water to the charging unit.
z
Do not make any repair attempts to the units. Return it to its original point of purchase
for repair by a qualified engineer. Opening and tampering with the units may invalidate
its guarantee.
z
Do not expose the unit to extreme and sudden temperature changes, this may lead to
damage to the electronic parts in the unit.
24
SPECIFICATIONS:
Input voltage for AC/DC adapter
:
100-240 VAC
Charging current range
:
200 mA - 700 mA
Max charging capacity (capacity of rechargeable batteries) :
3000 mAh
Dimensions (L x H x W) of
Charging unit
: 2.95” x 5.11” x 1.57”
(75 x 130 x 40 mm)
LIABILITY DISCLAIMER:
z
The manufacturer and supplier cannot accept any responsibility for any improper or
incorrect use and any consequences occurred.
z
Any performance of repairs or alternations by someone other than the original
supplier will invalidate the warranty.
z
This product is only designed to be used by people who have read and understood
this instruction manual.
z
The specifications of this product may change without prior notice.
z
This product is not a toy. Keep out of the reach of children.