background image

 

z

 

Overheat detection to protect rechargeable batteries from over-charging 

z

 

Minus delta voltage (-dV) detection for charge termination

 

z

 

Damaged batteries detection 

z

 

Discharge mode (first discharging and then charging) to remove memory effect of 
rechargeable batteries

 

z

 

Refreshing old rechargeable batteries by discharging/ charging cycles

 

z

 

Test function to check the capacities of rechargeable batteries 

 

z

 

Different Charging/ Discharging functions can be launched independently and 
simultaneously to each rechargeable battery in the compartments

 

z

 

Various display modes during charging/ discharging – the charging current (in mA), 
time elapsed (in hh:mm), the terminal voltage (in V) and accumulated capacities (in 
mAh or Ah) 

 

FUNCTION KEYS:

 

There are three easy-to-use function keys and four number keys in the charging unit:     
 
 
 
 

 

 

 
 
 
 
 
 
 
 
 
 

Compartment Number key 

Press and release the Number key to select a particular battery compartment for charge 
modes and/or display mode adjustment.   

 

MODE key   

The mode key shall first be pressed and held for about 5 seconds to activate the mode 
change. The subsequent pressing of the mode key will enable to toggle between the 
“Charge”, “Discharge”, “Test” and “Refresh” mode. To change the operating mode for an 
individual rechargeable battery, first press corresponding NUMBER key then press the 
MODE key. 

Compartment 
Number keys

DISPLAY key 

MODE key 

CURRENT key

 

DISPLAY key 

Press and release to select the displays of the charging current (in mA), time elapsed (in 
hh:mm), the terminal voltage (in V) and accumulated capacities (in mAh or Ah) during the 
charging or discharging process.   
To change the display content of a particular rechargeable battery, first press corresponding 
NUMBER key then press the DISPLAY key. 

 

CURRENT key 

Press to select the amount of current to be applied (within the first 8 seconds after batteries 
are inserted) in different operating modes (also see “

Start charging the rechargeable 

batteries

” below).   

 

OPERATING MODES OF THE CHARGING UNIT 

This powerful charging unit provides the following operating modes: 
a. 

Charge up the rechargeable battery 

(CHARGE)

 – to charge up the rechargeable 

battery, automatically switch to trickle charge after rechargeable battery is full. 

b. 

Discharge then charge up the rechargeable battery 

(DISCHARGE)

 – to discharge the 

rechargeable battery then charge it for minimizing the memory effect. 

c. 

Refresh the rechargeable battery 

(REFRESH)

 – to refresh the rechargeable battery to 

its maximum capacity by charging and discharging the rechargeable battery 

 

repeatedly until no further increase in the capacity is estimated. For old rechargeable 
batteries or those have not been used for a long times, refreshing may bring the 
rechargeable battery back to the optimum condition.   

d. 

Check the rechargeable battery capacity in mAh/ Ah 

(TEST)

   

 

CHARGE MODE   

Charging at 200 mA is the default-operating mode of the charging unit. User may select a 
charging current of 200, 500 or 700 mA. 

 

The estimated time of charging by various charging current is tabulated in Table 1. 

 

Table 1. Charging Time with various charging current 

Size of battery Battery Capacity Charging current selected (mA) Estimated charging time

700 

~3 hr 35 min 

500 ~5 

hr 

 

AA 2500 

mAh 

200 ~13 

hr 

 

700 ~60 

min 

500 ~84 

min 

AAA 700 

mAh 

200 

~3 hr 30 min 

 

 

Summary of Contents for Battery Charger

Page 1: ...ideal for use in the home office or on journey INVENTORY OF CONTENTS 1 Charging unit 2 Transformer 3 Instruction Manual The Charging unit 4 CAUTIONS 1 The charger is restricted to charging NiCd and Ni...

Page 2: ...ted capacities in mAh or Ah during the charging or discharging process To change the display content of a particular rechargeable battery first press corresponding NUMBER key then press the DISPLAY ke...

Page 3: ...the process and the selected mode will be undergone 11 During charging the different displays Charging current in mA Time elapsed in hh mm Terminal voltage in V and Accumulated capacities in mAh or A...

Page 4: ...resses DISPLAY key at this time charge icon instead of discharge icon will be displayed REFRESH MODE Old rechargeable batteries and those have not been used for a long time require refreshing This pro...

Page 5: ...eries to maintain the fully charged level This mode is automatically launched after rechargeable batteries are fully charged and kept at the charging unit The signal Full will be displayed on the LCD...

Page 6: ...00 mA to charge up the battery once the power source is back to normal regardless of the operating mode Charge Discharge Refresh or Test which has been selected by user before CARE AND MAINTENANCE z E...

Page 7: ...ge to or deterioration of any accessory or decorative surface 4 damage resulting from failure to follow instructions contained in your owner s manual 5 damage resulting from the performance of repairs...

Page 8: ...ver time It is not recommended to condition batteries until after they have bee charged and used 10 times As you use your batteries they will gain greater capacity and last longer It is common for you...

Reviews: